16. Adding A Reset Input (Hand push Mode) Into The IRIS Radio
Receiver
The following sequence of operations is required when adding an input, which is required
to reset the IRIS receiver. The inputs mode setting must be programmed as a hand push
and the input must be programmed into the UHF IRIS Radio Receiver as an Interrogator
transmitter. It should be noted that the IRIS receiver must have installed 7202
Interrogator software for this function to operate.
16.1 With the control keyswitch in
the “CLEAR” position the screen
should now display:
System Clear
01/10/93 13:26
16.2
Turn the control keyswitch to
the “RESET” position. The
screen will now display:
*** SYSTEM RESET ***
13:26
16.3 Press the “0” key, and the
screen will display:
Enter Your PIN
For Menus > _
=Done
=Del 13:26
16.4 Enter the engineering default
PIN: “221100” and press the
“
” button, and the screen will
now display:
|** Main Menu **|
> Pins & Access <
| System Support |
2=Help 13:27
16.5 Press the “
” button until the
screen displays:
| Time and Date |
> Radio Setup <
| Output Setup |
2 = Help 16: 37
16.6 Press the “1” button and the
screen will display:
| ** Radio Setup ** |
> Add Transmitter <
| Txer Details |
2 = Help 16:37
16.7 Press the “1” button and the
screen will display:
| -Add Transmitter-|
> Add Hand push <
| Add Moneyclip |
2 = Help 16:37
16.8 Press the “
” button until the
screen displays:
| Add Contact Txer |
> Add Interrogator <
| Add P-Call Txer |
2 = Help 16:37