EMS SYSTEM 7000
©2015 EMS Security Group Ltd. All rights reserved. TSD248 Iss 2 25/06/15 AJM
18
To change press Y and then enter. The display will then change to the following:
Input Number 1 is HANDPUSH
Input Number 2 is CONTACT
Change to HANDPUSH Y/N ?
If the input does not require to be changed press N or Enter. The display will then
change to show the next input.
This continues until all 8 contacts are looked at. On answering Y/N to contact 8 the
display will change to show the command menu. To check settings type
mode
to
re-enter menu.
10. TXD
9.1
The txd function when entered causes each of the inputs being used to transmit
three bursts of call in data. To enter this function type
txd
from the command
menu
and press the enter key. The display will then show,
Transmit Call Ins
Call in 08EA0000
Call in 08EA0000
Call in 08EA0000
Call in 08EA0001 }
Call in 08EA0001 } This is call in data for input 1
Call in 08EA0001 }
This is then repeated for all active inputs showing each of the inputs ID’s in three
transmitting bursts. Once completed it will carry on repeating the above sequence.
To exit this function press the enter key 3 times.
11. QUIT
11.1 To update any information changed and exit the programming mode
quit
must be
typed followed by pressing the enter key. The program mode is then exited. The
display will then show any transmissions from the transmitter in the following
format:
Transmitting Data: (hex transmission and ID code shown)