8.8  If  the  type  requires  changing,  from  the  command  menu  type 

type 

and  press  the 

enter key. The display will then show:- 

 

 

Input Number 1 is Alarm 

 

Change Y/N ? 

 

 

To change press Y and then enter.  The display will then change to the following: 

 

 

Enter new type 0 = NU, 1 = RESET 

 

2 = LOWBAT, 3 = TAMPER, 4 = LOCAL, 5 = ALARM 

 

 

Enter the required number and press enter.  The display will now show: 

 
 

Input Number 1 is NNNNNN ( Where N is the new option chosen) 

 
 

Input Number 2 is Alarm  

 

Change Y/N ? 

 
 

If you don’t require the input to be changed press N or Enter.  The display will then 
change to show the next input.  

 
 

This continues until all 8 contacts are looked at. On answering Y/N to contact 8 the 
display will change to show the command menu.  To check settings type

 type

 to re-

enter menu. 

 

9. MODE 

 

9.1

 

Each  of  the  transmitters  inputs  have  a 

mode

 setting, which sets the operation of 

the input.  The unit has two modes contact and hand push. The default for all inputs 
is set to contact. 

 
9.2

 

If  contact  is  selected  the  input  should  be  added  into  the  IRIS  receiver  as  a  N/0 
contact operated transmitter, this will then cause the input to transmit data on both 
an activation of the input and the reinstating of the input. This will be shown on the 
IRIS  when  its  being  reset,  as  it  will  show  which  inputs  have  not transmitted their 
restored signals by showing that the input is not reset. This contact setting is only 
recommended when the alarm type is set to either a local or alarm transmission. 

 
9.3

 

If  hand  push  is  selected  the  input  should  be  added  into  the  IRIS  receiver  as  an 
opposed  action  hand  push  transmitter,  this  will  then  cause  the  input  to  transmit 
data on an activation of the input.  This setting can be selected for all alarm types 
and is imperative for the correct activation of alarm types low battery, tamper and 
reset. 

 
9.4

 

If the mode requires changing, from the command menu type 

mode 

and press the 

enter key. The display will then show: 

 

 

Input Number 1 is CONTACT 

 

Change to HANDPUSH Y/N ? 

 

 

 

Содержание 7256

Страница 1: ...SYSTEM 7000 7941 EIGHT INPUT HIGH POWERED UHF TRANSMITTER INSTALLATION AND PROGRAMMING INSTRUCTIONS ...

Страница 2: ...NG CONNECTION DETAILS 6 5 INPUT PROGRAMMING 7 6 ID 15 7 CON 15 8 TYPE 16 9 MODE 17 10 TXD 18 11 QUIT 18 12 LOAD DEFAULT VALUES 19 13 INTERNAL INPUT WIRING 20 14 ADDING AN INPUT HAND PUSH MODE INTO THE IRIS RADIO RECEIVER 21 15 ADDING AN INPUT CONTACT MODE INTO THE IRIS RADIO RECEIVER 23 16 ADDING A RESET INPUT HAND PUSH MODE INTO THE IRIS RADIO RECEIVER 25 17 ASSIGNING TEXT DESCRIPTION FOR AN INPU...

Страница 3: ... if the contact is programmed as normally open or removed if normally closed see Figure 4 on page 19 for details On an input activation a signal will be transmitted to the receiver and displayed in the format programmed i e Alarm Zone Area 1 for an input that has been set as an Alarm input and programmed with the text description Zone Area 1 2 Tools Test Equipment 2 1 Only standard hand tools are ...

Страница 4: ...ion and requirements Please note both the eight input transmitter and the IRIS receiver will require an external power supply Figure 1 shows a typical IRIS radio system whilst Figure 2 shows an alternative system using a Single Channel 7703 Receiver Figure 1 7941 Half Watt Txer 7941 Half Watt Txer 7941 Half Watt Txer 7256 IRIS Rxer Eight Input Data Transmissions Eight Input Data Transmissions ...

Страница 5: ... 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 5 Figure 2 7941 Half Watt Txer 7941 Half Watt Txer 7941 Half Watt Txer 7703 Rxer Eight Input Data Transmissions Eight Input Data Transmissions ...

Страница 6: ...r physical connection details are as follows COMPUTER ISOLATED RS 232 PORT PIN 2 TX OUT PIN 3 RX IN PIN 5 COMMON CONNECT 4 2 All Computer to HyperTerminal connections are shown below in Figure 3 Figure 3 TAMPER LOOP 0V 12V DC SUPPLY COMMON CONNECT RX RX RX TX COMMON IN OUT CONNECT ISOLATED RS485 ISOLATED RS232 2 3 5 TO POWER SUPPLY 9 PIN SERIAL CONNECTOR ...

Страница 7: ... data or a hand push device which must be used for certain types of transmitted data and does not transmit restore data MODE A full explanation of all input settings and the operation of the inputs if selected is described in more detail in the following paragraphs under their menu commands headings 5 2 The inputs have their settings defaulted to the following parameters Inputs 1 8 ID A0001 A0008 ...

Страница 8: ...SYSTEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 8 Now enter your desired connection description Then click on the OK button and the screen will change to the following ...

Страница 9: ...STEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 9 Now select the Comm Port required as below Then click on the OK button and the screen will change to the following screen ...

Страница 10: ...7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 10 Now select the following settings Once completed click on the Apply button and then the OK button The screen will change to display ...

Страница 11: ...EMS SYSTEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 11 Now select Call and Disconnect and the screen will change to display ...

Страница 12: ... 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 12 Now select File and Properties The screen will change to display Now select the Settings tab and the screen will change as below ...

Страница 13: ...015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 13 The Settings should be set as follows Once the settings are as above click on the ASCII Setup button and check that the settings are as follows ...

Страница 14: ...he settings are as above click on the OK button then on the next window click on the OK We can now establish a connection by selecting Call and Call as below Once completed HyperTerminal is configured Please Note To prevent future reconfiguration the HyperTerminal session can be saved for future use ...

Страница 15: ...ready programmed into the IRIS unit 6 3 To change the inputs identification number from the command menu type id and press the enter key The display will then show Input No 1 ID code hex is A0001 Change Y N To change the ID press Y and then the enter key the display will now show New ID Code hex Enter the new ID code and press enter If the hex number is a valid number the display will change to sh...

Страница 16: ...nput requires it s mode setting programmed to hand push and should be added into the IRIS as an opposed action hand push 8 6 LOCAL If selected on triggering this input a local alarm transmission will be sent to the IRIS receiver This input can have it s mode setting set to either hand push or contact and can be added into the IRIS as an opposed action hand push or N O contact operated transmitter ...

Страница 17: ...peration of the input The unit has two modes contact and hand push The default for all inputs is set to contact 9 2 If contact is selected the input should be added into the IRIS receiver as a N 0 contact operated transmitter this will then cause the input to transmit data on both an activation of the input and the reinstating of the input This will be shown on the IRIS when its being reset as it ...

Страница 18: ...transmit three bursts of call in data To enter this function type txd from the command menu and press the enter key The display will then show Transmit Call Ins Call in 08EA0000 Call in 08EA0000 Call in 08EA0000 Call in 08EA0001 Call in 08EA0001 This is call in data for input 1 Call in 08EA0001 This is then repeated for all active inputs showing each of the inputs ID s in three transmitting bursts...

Страница 19: ...systems inputs Default values for the inputs are as follows Inputs 1 8 ID A0001 A0008 Con Normally Open Type Alarm Mode Contact 12 2 To change all of the inputs to their default settings type load defaults and press the enter key The display will now show Load Default Values Y N Press the Y key and then enter the display will then change to show Please Wait The system will then return to the comma...

Страница 20: ...EMS SYSTEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 20 13 Internal Input Wiring Connection Drawing Figure 4 ...

Страница 21: ...the engineering default PIN 221100 and then press the button the screen will now display Main Menu Pins Access System Support 2 Help 13 27 14 5 Press the button until screen displays Time and Date Radio Setup Output Setup 2 Help 16 37 14 6 Press the 1 button and the screen will display Radio Setup Add Transmitter Txer Details 2 Help 16 37 14 7 Press the 1 button and the screen will display Add Tra...

Страница 22: ...e the screen will change to display Operate Transmitter Again or press Escape to cancel 16 38 14 12 Using the same operation once again generate a transmission after a short period of time the screen will change to display Hand Push 001 Added Push any key 16 38 14 13 You may now add additional inputs by repeating the actions detailed If no further inputs are to be added then escape from this menu ...

Страница 23: ...e screen will now display Enter Your PIN For Menus _ Done Del 13 26 15 4 Enter the engineering default PIN 221100 then press the button and the screen will display Main Menu Pins Access System Support 2 Help 13 27 15 5 Press the button until the screen displays Time and Date Radio Setup Output Setup 2 Help 16 37 15 6 Press the 1 button and the screen will display Radio Setup Add Transmitter Txer D...

Страница 24: ...ng upon N O or N C input and the screen will display Reset Transmitter NOW 16 38 15 12 After a short period of time the screen will change to display Operate Transmitter Again or press Escape to cancel 16 38 15 13 Using the same operation once again generate a transmission after a short period of time the screen will change to display Contact 001 Added Push any key 16 38 15 14 You may now add addi...

Страница 25: ... should now display System Clear 01 10 93 13 26 16 2 Turn the control keyswitch to the RESET position The screen will now display SYSTEM RESET 13 26 16 3 Press the 0 key and the screen will display Enter Your PIN For Menus _ Done Del 13 26 16 4 Enter the engineering default PIN 221100 and press the button and the screen will now display Main Menu Pins Access System Support 2 Help 13 27 16 5 Press ...

Страница 26: ...ease all buttons NOW 16 38 16 11 After a short period of time the screen will change to display Operate Transmitter Again or press Escape to cancel 16 38 16 12 Using the same operation once again generate a transmission after a short period of time the screen will change to display Interrogator 001 Added Push any key 16 38 16 13 You may now add additional inputs by repeating the actions detailed I...

Страница 27: ...reen will display Txer Details Name by Number Name by Tx 2 Help 16 37 17 6 Press the button and the screen will display Name by Number Name by Tx View Names 2 Help 16 37 17 7 Press the 1 button and the screen will display Operate Transmitter NOW or press Escape to cancel 16 38 17 8 Generate a transmission by activating the input that requires re texting and the screen will display Release all butt...

Страница 28: ... a blank space into the new device name being entered 3 Exits to the previous menu 4 Moves the alphabet wheel of characters to the Left by one character space at a time 5 Enters the character in the centre directly above the character selector 6 Moves the alphabet wheel of characters to the Right by one character space at a time 7 Moves the flashing cursor to the left through the new device name b...

Отзывы: