IM 610179-1, Rev 02
08/25/06
Page 9
This unit will be installed by a professional installer using the appropriate anchors, etc. to
support a minimum of 30 lbs(actual weight of unit is 10 lbs) with four(4) #8 screws a minimum of
1 ¼ inch in length(not provided with unit) for the surface where the unit is being mounted in the
orientation shown located within 2.95 meters of the unit.
Standard hand/power tools possessed by any qualified installer are adequate for both installing
and removing the unit.
The power supply cord must not be attached to the building surface nor run through walls,
ceilings, floors, and similar openings in the building structure. The power supply cord must be
inserted in a standard receptacle.
CAUTION !
DOUBLE POLE / NEUTRAL FUSING
Select Mounting location of Donor directional antenna and orient toward the base station to
maximize signal level. For best performance this should be line of sight between the Donor
antenna and the base station antenna.
Alarms
All alarms are considered major since there are no field replaceable modules in the unit. All
alarms are indicated locally and immediately by the Alarm LED indicator blinking red. Once the
Alarm State has existed for 5 minutes, the Alarm LED will have a constant red indication.
Certain problems will result in the unit automatically shutting down after 5 minutes of sensed
failure. This is done by disabling the RF output stages in both the uplink and downlink signal
paths. Removing DC power from the unit for a period of 30 seconds or longer will reset the auto
shut down.
Failure Action
Alarm
Code
Alarm Cleared
0
Synthesizer Lock, Uplink
Auto Shut Down
1
Synthesizer Lock, Downlink
Auto Shut Down
2
Downlink RF Overdrive
Auto Shut Down
3
Uplink RF Overdrive
Auto Shut Down
4
No Downlink RF Detected*
Alarm Only
5
Internal Voltage Failure
Alarm Only
6
Low Current Draw
Alarm Only
7
Keep Alive(1)
Auto Shut Down
8
External Alarm
Alarm Only
9
*Minimum detectable RF level is approximately -10dBm. Unit will alarm below this level.
Indicators
The EkoMini is equipped with three LED indicators on the end of the unit which provide the
following information:
Indicator State
Description
Содержание EkoMini M1.9
Страница 15: ...IM 610179 1 Rev 02 08 25 06 Page 14 Figure 1 ...
Страница 16: ...IM 610179 1 Rev 02 08 25 06 Page 15 Figure 2 ...
Страница 17: ...IM 610179 1 Rev 02 08 25 06 Page 16 Figure 3 ...
Страница 18: ...IM 610179 1 Rev 02 08 25 06 Page 17 Figure 4 ...
Страница 33: ...IM 610179 1 Rev 02 08 25 06 Page 32 SNMP Log Page This page shows SNMP messages being sent by the repeater ...
Страница 37: ...IM 610179 1 Rev 02 08 25 06 Page 36 ...
Страница 39: ...IM 610179 1 Rev 02 08 25 06 Page 38 ...
Страница 41: ...IM 610179 1 Rev 02 08 25 06 Page 40 ...