EMPYRE PRO SERIES INSTALLATION AND OPERATION MANUAL • 2009
15
INSTALLATION
Optional Heat Exchanger
Stainless Steel Water to Water Heat
Exchanger, Figure 2, can be used in place
of a side arm.
COLD
WATER
MIXED
WATER
TEMPERING VALVE
Hot water
Used for
bleeding air
WATER HEATER
Use for
filling system
Supply
from
Pro Series
furnace
To domestic
heating
system
Water heater drain
CAUTION
Do not eliminate
the existing
temperature relief
valve.
SIDE ARM HEA
T EX
CHANGER
NOTE
: Keep bottom loop (and side arm) as low as possible.
PUMP
BALL VALVE
THERMOMETER
BOILER DRAIN
TEMPERING OR
MIXING VALVE
SYMBOL INDEX
Have a qualified electrician check
to ensure changes or modifications
are made in accordance with the
manufacturer’s specifications and
performed by qualified, licensed
personnel in accordance with local
building codes.
Side Arm Installation
To domestic
heating
system
Hot water in
from
Pro Series
furnace
To top of hot water tank
From bottom of hot water tank
Figure 1
Figure 2
IMPORTANT
When hooking up
the Empyre Pro
Series to a domestic hot
water heater, a tempering
valve must be installed,
to prevent scalding hot
water from reaching the
hot water outlets.