EMPYRE PRO SERIES INSTALLATION AND OPERATION MANUAL • 2009
INSTALLATION
Hookup to Existing Heat System
(Water to Air)
1. Install the circulating pump on the supply
line and ensure that the pump’s motor is in a
horizontal position.
2. Install the heat exchanger radiator in the hot
air plenum of the forced air furnace, Figure 2,
according to the manufacturer’s instructions,
taking care to seal all joints and holes.
3. After installing the heat exchanger to the
forced air furnace system, check to ensure
that the air flow is the same as specified by the
manufacturer of the existing heating system.
The furnace fan should not generally need
to be changed in order to accommodate the
addition of the heat exchanger.
Belt Driven Hot Air Fan
4. Pulleys on motor and
blower may have to be
adjusted to obtain the
proper rate of air flow.
Direct Drive Fan
5. Adjust the motor speed to
obtain the correct air flow.
Thermostat
6. Install a second thermostat to allow the blower
to operate separately from the furnace.
7. The existing thermostat should be set several
degrees lower than the new thermostat.
This will allow the regular system to cut in,
should the Pro Series run out of wood and the
temperature drop below the second setting.
IMPORTANT:
Have a qualified electrician check to ensure that these
changes do not cause the electrical motor to be overloaded.
Any modification to the existing forced air heating system
must be made in accordance with the manufacturer’s
specifications and performed by qualified, licensed
personnel in accordance with local building codes.
Under Floor Heat
1. A 24 V thermostat with relay should be used
in a house. For garage or shop, wire pump
through an in-line thermostat.
2. Each zone can be manually adjusted with the
restrictor valves on the supply header.
3. Adjust mixing valve to run supply water
temperature between 110˚F - 120˚F
(43˚C - 49˚C) in concrete floor installation.
Figure 2
Figure 3
Return header