AUTOMATIC HUMIDIFIER OPERATION

The Mantis Power-Vent High-Efficiency Fireplace has an automat

-

ic humidifier designed into the fireplace. As the fireplace operates, 

condensate is created and is collected in a tank inside the fire

-

place. The condensate pump will take the collected condensate  

and pump it to a stainless steel tray where it evaporates into the 

airstream, adding humidity to the heated space. 

Note:

 When the automatic humidifier is engaged and is transfer

-

ring  the  condensate,  there  may  be  a  noticeable  hissing  sound. 

This is normal, and the sound should persist for less than 30 sec

-

onds. 
The amount of condensate created will vary based on several 

factors including but not limited to location of fireplace, air tem

-

perature, length of venting, and whether the vent pipe is horizontal 

or vertical. The humidifier will operate intermittently while the fire

-

place is operating.
While the condensate pump is transferring the condensate from 

the  tank  to  the  tray,  the  “AUX”  symbol  will  display  during  pump 

 

operation. See Page 32, Figure 48. Once the condensate is trans

-

ferred, the symbol will turn off.

Figure 63

MAINTENANCE & SERVICE

The Mantis should be inspected and serviced annually by a quali-

fied service person. This will ensure that the appliance is operating 

safely  and  efficiently.  Should  you  suspect  any  abnormal  opera

-

tion, contact a service person that has been trained to service this 

product. 

Cleaning the Glass Door

After the initial paint curing, a slight film may form on the glass. It is 

recommended to clean the glass with gas fireplace glass cleaner.

The glass will need to be cleaned periodically during the year. Use 

care when removing and cleaning the glass. In the event the glass 

needs replaced, contact a qualified service person. Only glass ap

-

proved by Empire Comfort Systems Inc. may be used, any substi

-

tute glasses will void the warranty. 

CAUTION

Do not attempt to clean the glass when it is hot. Do not 

strike or hit the glass. 

WARNING

Do not operate this appliance without the glass door 

in place. Do not operate if the glass front is broken or  

damaged. Do not use the glass door if the gasket is missing 

or is damaged. 

CAUTION

Be certain the glass is cool before handling.

Removing the Glass Door

1.  Remove the lower louvered panel by lifting up then pulling 

out.

2.  Release the two hinge clips on underside of firebox.

3.  Angle  the  bottom  of  glass  assembly  approximately  60  de

-

grees out from firebox. Gently pull glass assembly away from 

firebox. Do not damage or remove the gasket from the door. 

Resetting the Fireplace

WARNING

Potential  risk  of  fire,  electric  shock,  and  personal  injury. 

Take precautions to reduce such risks

CAUTION

Label all wires prior to disconnection when servicing  

controls. Wiring errors can cause improper and dangerous 

operation. Verify proper operation after servicing.

To reset the fireplace, press the mode selection button on the dis

-

play panel repeatedly until the fireplace cycles through the “OFF” 

setting once. If the error has been cleared, the fireplace will oper

-

ate normally. If the error is still present, consult a qualified service 

technician.

Cleaning the Porcelain Liners

Over  time  a  film  may  form  on  the  porcelain  liners.  It  is  recom

-

mended to clean the liners with gas fireplace glass cleaner. 

The liners will need to be cleaned periodically during the year. The 

glass door will need to be removed to clean the liners. Use care 

when removing the glass. In the event the liners need to be re-

placed, contact a qualified service person. Only liners supplied by 

Empire Comfort Systems may be used. Any substitute will void the 

warranty.

Содержание Mantis FG28BM-1

Страница 1: ...ult in serious injury death or property damage Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try...

Страница 2: ...olinear Transition Vent Kit 17 Direct Vent and Colinear Vent Examples 18 20 PVVK 24H and PVVK 48H Vent Kit 21 23 Rough Framing Dimensions 24 Insert Into Masonry Fireplace 25 Clearance to Combustibles...

Страница 3: ...A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals If the bar...

Страница 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Страница 5: ...certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaus...

Страница 6: ...es Always consult with local authorities be fore installing any gas appliance Combustion and Ventilation Air U S National Fuel Gas Code NFPA 54 ANSI Z223 1 NFGC Air for Combustion and Ventilation Elec...

Страница 7: ...Number Description FWKQ28BL In Wall Surround Kit Picture Frame with Barrier FHKQ28BL In Wall Surround Kit Louverless with Barrier FIKQ28BL 38 Wide X 30 7 8 Tall Insert Surround Kit with Barrier FFKQ2...

Страница 8: ...t shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle purchase an adapter w...

Страница 9: ...ty warnings exactly could result in serious injury death or property damage After gas piping to the fireplace is complete all connections must be tested for gas leaks This includes pipe connections at...

Страница 10: ...service regulator vent outlet 6 ft 182 cm J Clearance to non mechanical air supply inlet to building or the com bustion air inlet to any other appliance 6 in 15 cm for appliances 10 000 Btu h 3 kW 9...

Страница 11: ...exterior wall for ease of venting The flue exhaust pipe and inlet air pipe should be located between wall studs The required opening for venting is 1 7 8 inch in diameter for 1 1 2 inch PVC pipe For...

Страница 12: ...n installing a Mantis into an existing fireplace The flex vent kit can be cut down but can only be cut from one end Cement PVC Joints Cut End Cement PVC Joints Once length is determined install two 10...

Страница 13: ...ilable from Empire Comfort Systems Inc Termination Cap PVVTC Vertical exhaust cap for use with 1 1 2 PVC pipe installation Termination cap also used with colinear transition plate model PVCT Refer to...

Страница 14: ...ength is 27 feet The two 90 elbows are equivalent to six feet bringing the total to 40 feet 90 ELBOW 2 61 0cm 27 8 2m 5 1 5m VENT TERMINAL 90 ELBOW NOT COUNTED 3 FEET FIRST 90 DOES NOT GET COUNTED WHE...

Страница 15: ...ts are necessary in the interest of safety Figure 11 Single Flue Vertical Vent Run with 45 degree elbows WARNING Major U S building codes specify minimum chimney and or vent height above the rooftop T...

Страница 16: ...LUE HORIZONTAL ADAPTER MODEL PVVK FC 1 Attach colinear adaptor to back of fireplace with two screws 2 When adapter is connected continue with your vent run Cementing PVC joint is recommended but not r...

Страница 17: ...W LEVEL Installation of the Colinear Transition Plate 1 Attach the plate to chimney chase flat roof or outside wall with four screws Use outdoor sealant to seal the transition plate to the surface 2 C...

Страница 18: ...a minimum of three inches above the inlet air pipe The flue must be at least twelve inches from the roof line and it is recommended to be at least twelve inches above the maximum expected snow level a...

Страница 19: ...e 13 Part number PVVTC can also be used Figure 17 In both vertical and horizontal colinear direct vent applications a colinear transition plate model PVCT can be used to minimize clearances between in...

Страница 20: ...12 ABOVE THE EXPECTED SNOW LEVEL 3 24 OPTION OPTION AIR INTAKE PTRAP 2 90 ELBOWS SUPPLIED BY INSTALLER OR TERMINATION CAP MODEL PVVTC PTRAP TO FACE AWAY FROM ROOF EXHAUST TERMINATION CAP MODEL PVVTC P...

Страница 21: ...et duct to rear of fireplace six screws Step 4 Install silicone around connection between co axial adaptor and co axial air inlet duct 4 1 2 MINIMUM VENT LENGTH 3 13 16 MINIMUM TUBE LENGTH Step 5 Slid...

Страница 22: ...nch pipe 45 elbows can be purchased from a local hardware store 47 5 1 2m Maximum Horizontal Venting 47 1 2 1 2 m Minimum Horizontal Venting 4 10 2 cm EXHAUST OPENING MUST BE POINTED DOWNWARD Direct V...

Страница 23: ...m Exterior Grade Dimension EXTERIOR GRADE FLUE CENTER 12 30 5cm MIN Figure 25 Minimum Exterior Grade Dimension Existing Fireplace Installation PVVK 24H AND PVVK 48H CO AXIAL VENT KIT cont DIRECT VENT...

Страница 24: ...3 4 maximum when using FHKQ28 Surround Kit 28 1 2 maximum when using FFKQ28 Surround Kit 29 1 2 maximum when using FIKQ28 Surround Kit 32 maximum when using FWKQ28 Surround Kit C 28 1 2 minimum 31 re...

Страница 25: ...round Kit 28 1 2 maximum when using FFKQ28 Surround Kit 29 1 2 maximum when using FIKQ28 Surround Kit 32 maximum when using FWKQ28 Surround Kit C 28 1 2 minimum 31 recommended for service 33 maximum w...

Страница 26: ...s been tested and approved for zero clearance to combustible materials It is recommended that clearances as listed above should be maintained to allow for removal of the product for servicing Figure 3...

Страница 27: ...urround Kit FFKQ28 BL CM HP SS Contains surround hood lower front Figure 36 Fireplace with Flex Vent PVVK CFA FLEX VENT KIT 23 1 2 24 3 4 MIN 6 1 2 SPECIFICATIONS 17 3 16 3 9 16 FLUE OUTLET 24 3 4 MIN...

Страница 28: ...ECTRIC CORD GAS LINE OPENING 1 1 8 7 5 16 4 3 16 2 5 8 6 1 8 3 9 16 13 16 1 28 Fireplace 38 Inch Surround FIKQ28 BL CM HP SS Contains surround hood lower front Figure 40 Figure 41 4 8 Figure 42 Cleara...

Страница 29: ...pply line Any excess flexible line can be pushed back into the fireplace 3 Place rubber grommet that is supplied in hardware packet over the flexible gas line and secure in the hole in the back of the...

Страница 30: ...the safety information above 2 Open bottom louver assembly or open the service ac cess panel 3 Turn off all electric power to the appliance 4 Turn gas line valve to OFF 5 Close bottom louver assembly...

Страница 31: ...hazard and should be plugged directly into a properly grounded three prong recep tacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle an adapter which has two pro...

Страница 32: ...quence will initiate after this test 3 The igniter HSI will energize and start to glow red 4 After 20 seconds the gas valve will open and ignite the burner on high The flame sensor will verify the fla...

Страница 33: ...circum stances the circulating blower will start three to five minutes after ignition of the burner Once the fireplace is turned off or the call for heat has been sat isfied the circulating blower wi...

Страница 34: ...Mode Select Manual Thermostatic button switches the remote from Manual MAN mode to Thermostatic AUTO mode When using this button in conjunction with other buttons you can also access menus like the cl...

Страница 35: ...If flame power is at level 5 the MAX message also appears 14 Clock setting symbol When this symbol appears you can adjust the clock setting displayed by the digits 9 15 Flame power bars one bar low fi...

Страница 36: ...day press the O button again to confirm you settings and exit the menu Figure 53 The days of the week are indicated by two letter codes MO Monday TU Tuesday WE Wednesday TH Thursday FR Friday SA Satu...

Страница 37: ...fireplace If the remote is in standby PILOT mode press and release the power button If the remote is off press and hold the power button for two seconds See Figure 56 After a start up phase lasting ab...

Страница 38: ...ymbol appears in solid black MAN Figure 57 Switching from Manual to Thermostatic Mode To switch from MANUAL to THERMOSTATIC mode press the mode button The message MAN disappears and the message AUTO a...

Страница 39: ...ons with the fireplace the fireplace will no longer receive any room temperature measurements and will therefore continue to function at the same power setting that was established before communicatio...

Страница 40: ...art the fireplace at 10 00 but you already feel cold at 9 00 and want to start the fireplace up early press the up and down button The command to start the fireplace at 10 00 will then be ignored beca...

Страница 41: ...ition probe Red LED permanently ON Green LED performs one blink followed by a one second pause High water level fault A2 Yellow LED permanently OFF Check pump functionality Red LED permanently ON Gree...

Страница 42: ...he event the glass needs replaced contact a qualified service person Only glass ap proved by Empire Comfort Systems Inc may be used any substi tute glasses will void the warranty CAUTION Do not attemp...

Страница 43: ...rom the fireplace To remove the surround lift and remove from the support bracket hooks Remove the filter retainers and filters from the inside bottom flange by re moving the screw holding the filter...

Страница 44: ...esired look Follow the diagrams in this manual for placement of media and clearance to burner open ings CAUTION Use of gloves and eye protection is required while applying the decorative glass CAUTION...

Страница 45: ...31792 4 1115 Page 45 Figure 67 Figure 68 Figure 69 Figure 70...

Страница 46: ...SEMBLY LPG 29 R6207 ELBOW 90 DEGREE 5 16 X 3 8 NPT 30 29425 SUPPLY TUBING 31 R11391 PRESSURE SWITCH 32 29450 CONTROL BOARD COVER 33 R11726 00 CONTROL BOARD 34 29419 ELECTRICAL PARTS PLATE 35 R11189 DI...

Страница 47: ...13 14 16 17 15 16 17 13 14 15 2 1 2 1 11 10 11 10 7 8 5 6 2 1 3 4 7 8 5 6 2 1 3 4 10 10 5 5 6 7 8 9 7 6 9 8 2 1 3 4 2 1 3 4 4 4 3 3 2 1 2 1 9 10 1 2 3 4 21 5 19 41 42 38 39 40 36 47 57 50 48 46 49 50...

Страница 48: ...be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number an...

Страница 49: ...of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties of the Owner The appliance must be installed by the selling dealer or his de...

Страница 50: ...31792 4 1115 Page 50 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 51: ...31792 4 1115 Page 51 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 52: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: