Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you 

can smell the odorant in propane.

 Smoking can decrease your 

ability to smell. Being around an odor for a time can affect your 

sensitivity or ability to detect that odor. Sometimes other odors in 

the area mask the gas odor. People may not smell the gas odor 

or their minds are on something else. Thinking about smelling a 

gas odor can make it easier to smell.

The odorant in LP-gas is colorless, and it can fade under 

some circumstances.

 For example, if there is an underground 

leak, the movement of the gas through soil can filter the odorant. 

Odorants in LP-Gas also are subject to oxidation. This fading can 

occur if there is rust inside the storage tank or in iron gas pipes.

The odorant in escaped gas can adsorb or absorb onto or into 

walls, masonry and other materials and fabrics in a room. That will 

take some of the odorant out of the gas, reducing its odor intensity.

LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precau-

tions which can protect both you and your family from an 

accident. Read them carefully now, then review them point by 

point with the members of your household. Someday when 

there may not be a minute to lose, everyone's safety will depend 

on knowing exactly what to do. If, after reading the following 

information, you feel you still need more information, please 

contact your gas supplier.

• 

Learn to recognize the odor of LP-gas.

 Your local LP-Gas 

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

• 

If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

•  Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to light 

pilot lights, perform service, or make adjustments in an area 

where the conditions are such that you may not detect the 

odor if there has been a leak of LP-Gas.

• 

Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been 

out of service for a time may develop internal rust which will 

cause odor fade. If such conditions are suspected to exist, 

a periodic sniff test of the gas is advisable. 

If you have any 

question about the gas odor, call your LP-gas dealer. A 

periodic sniff test of the LP-gas is a good safety measure 

under any condition.

• 

If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

• 

If you experience a complete "gas out," (the container is un-

der no vapor pressure), turn the tank valve off immediately. 

If the container valve is left on, the container may draw in 

some air through openings such as pilot light orifices. If this 

occurs, some new internal rusting could occur. If the valve is 

left open, then treat the container as a new tank. Always be 

sure your container is under vapor pressure by turning it off 

at the container before it goes completely empty or having it 

refilled before it is completely empty.

•  Do not operate electric switches, light matches, use your 

phone. Do not do anything that could ignite the gas.

•   Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•   Close all gas tank or cylinder supply valves.

•   LP-Gas is heavier than air and may settle in low areas such 

as basements. When you have reason to suspect a gas leak, 

keep out of basements and other low areas. Stay out until 

firefighters declare them to be safe.

•   Use your neighbor's phone and call a trained LP-Gas service 

person and the fire department. Even though you may not 

continue to smell gas, do not turn on the gas again. Do not 

re-enter the building, vehicle, trailer, or area.

• 

 Finally,

 let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then 

check and relight the gas appliance for you.

SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. 

That's your signal to go into immediate action!

SAFETY INFORMATION FOR USERS OF LP-GAS

Содержание GWT-50-3

Страница 1: ...or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any ph...

Страница 2: ...ough In Instructions 8 9 Finishing Instructions 9 10 Optional Thermostat Location SG Models 11 Lighting Instructions 12 Vent Safety Shutoff System 13 Proper Main Burner Flame 13 Proper Pilot Flame 13...

Страница 3: ...inspectedbeforeuseandatleast annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control comp...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on...

Страница 5: ...all be located or protected so it is not subject to physical damage by a moving vehicle Qualified Installing Agency Installation and replacement of gas piping gas utilization equipment or accessories...

Страница 6: ...as well as condensation of flue products an insulated vent enclosure is recommended Use Type B vent pipe and maintain at least a one inch 25mm clearance to combustibles Use metal thimble to protect ve...

Страница 7: ...at a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles...

Страница 8: ...ts Do not install in a closet alcove or small hallway where the furnace could be isolated by closing doors to the heated space When location is selected check the walls attic and roof to make sure the...

Страница 9: ...finish materials to project into furnace recess 66 1 8 1679 mm WALL OPENING 14 368 mm Figure 4 Installing Furnace Figure 5 Cleartherecessofalldebris andremoveanywoodplaster grounds Stand the furnace...

Страница 10: ...o header with one 1 8 x 3 8 Phillips screw when optional blower is not installed Attention Use outside clearance holes on outer casing top for attachment to header with two 2 8 x 3 8 Phillips screws w...

Страница 11: ...on a good pilot flame The flame must cover the top of the thermopile Cleaning of the pilot orifice and burner may be required due to spiders System Check Figure 7 A millivolt meter is required to che...

Страница 12: ...l door 4 Push in gas control knob slightly and turn clockwise to OFF Do not force 5 Replace control access panel control door 1 STOP Read the safety information above 2 Set the thermostat to lowest se...

Страница 13: ...hort blue inner flame with a much larger light blue outer flame The burner does not have a primary air adjustment The flame will be proper if the factory set pressure and orifice are used After the fu...

Страница 14: ...e lighter rod to light pilot with a match If Pilot Does Not Light By Any Means 1 Check gas control knob for being in the Pilot position 2 Check pilot adjustment for being full open counterclockwise to...

Страница 15: ...listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Descrip...

Страница 16: ...32039 1 0314 Page 16 PARTS VIEW 7 5 6 4 8 9 10 13 16 22 23 24 25 26 20 22 23 26 25 24 21 19 18 9 27 10 11 12 13 17 8 15 14 6 5 7 4 3 2 1 28 12 29 30 30...

Страница 17: ...right side of the outer casing carefully bend or loop capillary wire around control This will enable the sensing bulb to be positioned at the bot tom of the unit 8 Secure sensing bulb on the inside a...

Страница 18: ...rews from Step 3 to wall 12 Attach caps and plugs from blower housing and blower front 13 Attach blower front to blower housing with 4 8 x 3 8 screws from Step 6 14 Installation of optional blower ass...

Страница 19: ...d receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded receptacleanditswireconnectedtothereceptaclemountingscrews With this wire completing...

Страница 20: ...Systems Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair qu...

Страница 21: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Страница 22: ...rols Thermostats Accessories and Parts Should any remote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair o...

Страница 23: ...uides inflammables dans le vois nage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez a aucun interrupteur Ne pas vous...

Страница 24: ...placement du Thermostat Mod les SG 11 Instructions d Allumage 12 Le Syst me de Fermeture de S ret de l vent 13 Aspect Convenable de la Flamme du Br leur Principal 13 Aspect Convenable de la Flamme de...

Страница 25: ...yages seront requis Il est imp ratif que les compartiments de commandes les br leurs et les passages de circulation d air de l appareil soient gard s propres Ne rien mettre autour de la fournaise qui...

Страница 26: ...de ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Ne pas ouvrir les soupapes d approvisionnement de gaz m me si vo...

Страница 27: ...s Tousles quipementsdanslesgaragesr sidentielsemployant du gaz doivent tre install s de fa on ce que les br leurs et les appareils pour allumer les br leurs doivent tre situ s au moins 45 7cm au dessu...

Страница 28: ...nt un toit plat peuvent avoir une vacuation inad quate Un d lai de l vacuation ad quate se fera lorsque le tuyau d vacuation est froid par cons quent l interrupteur de s ret de l vent fermera la fourn...

Страница 29: ...cept es par les autorit s ayant juridiction L tat de Massachusetts exige qu une connexion flexible d un appareil n exc de pas une longueur de trois pieds Test de Pression du Syst me d Alimentation de...

Страница 30: ...le grenier et le toit pour tre certain qu il n y a pas d obstruction telles que des tuyaux des fils lectriques etc lesquels entraveraient l installation de la fournaise ou le tuyau d vacuation Note Si...

Страница 31: ...NE PRISE DE COURANT 115VOLT POUR LA SOUFFLERIE FACULTATIVE BAS DU REBORD CLOU DU COLLECTEUR PLAQUE COLLECTRICE 62 1581 mm 14 368 mm LAMBOURDE 2 x4 51mm x 102mm Figure 2 VENT B AVEC UN ADAPTATEUR BW JO...

Страница 32: ...ux 2 vis Phillips 8 x 3 8 lorsque la soufflerie facultative est install e 3 Aligner les trous libres au bas de la paroi ext rieur avec les trous de vis qui sont sur les supports de la paroi en ajustan...

Страница 33: ...lamme ad quate de la veilleuse La flamme doit recouvrir le haut de la thermopile Le nettoyage de l orifice de la veilleuse et du br leur doit tre fait cause des araign es V rification du Syst me Figur...

Страница 34: ...voir lectrique de l appareil si applicable 13 Mettre le thermostat au r glage d sir 1 Mettre le thermostat au plus bas r glage 2 Si l entretien doit tre fait teindre tout le pouvoir lectrique l appare...

Страница 35: ...bleue int rieure avec une flamme ext rieure bleue p le beaucoup plus grande Il n y a pas d ajustement d air primaire pour le br leur La flamme sera ad quate si la pression pr ajust e l usine et les or...

Страница 36: ...euse ne s Allume Pas 1 V rifierleboutondecontr ledegaz ildoit tredanslaposition Veilleuse 2 V rifier l ajustement de la veilleuse il doit tre compl tement ouvert dans le sens oppos des aiguilles d une...

Страница 37: ...vendeur Toutes les pi ces num r es dans la liste ont un num ro de pi ce Lorsque vous commandez des pi ces premi rement obtenez le num ro du mod le sur la plaque d identification de l appareil Puis en...

Страница 38: ...32039 1 0314 Page 38 VUE DES PI CES 7 5 6 4 8 9 10 13 16 22 23 24 25 26 20 22 23 26 25 24 21 19 18 9 27 10 11 12 13 17 8 15 14 6 5 7 4 3 2 1 28 12 29 30 30...

Страница 39: ...oient endommag sparunsurchauffage ceux cidoivent tre plac s ad quatement Un acheminement inad quat des fils de la commande lumineuse distance peut avoir pour r sultat d endommager les fils et avoir un...

Страница 40: ...tion de la soufflerie facultative est compl t e Attention Lorsque vous installez le ch ssis de la soufflerie sur le mur faites attention de ne pas endommager le serpentin du moteur Installation de la...

Страница 41: ...le fil doit tre attach la vis du support de la prise de courant Avec ce fil compl tant la mise terre la fiche de l appareil peut tre branch e dans l adaptateur AVERTISSEMENT D brancher l accessoire de...

Страница 42: ...NOTES DE SERVICE Date Nom du distributeur Nom du technicien de service Entretien effectu notes...

Страница 43: ...Pi ces Radiateurs foyers et barbecues Able Distributors 2501 North Central Avenue Chicago IL 60639 T l phone 773 889 5555 Sans frais 800 880 2253 T l copieur 773 466 1118 Website www abledistributors...

Страница 44: ...t Dommages pouvant r sulter de l emploi de l emploi abusif ou d une installation incorrecte de cet appareil Frais de d placement de diagnostic et de transport des pi ces sous garantie vers et depuis l...

Отзывы: