Instructions to Installer

1. Installer must leave instruction manual with owner after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with the fireplace.

3. Installer should show owner how to start and operate the 

fireplace.

This  direct  vent  gas  fireplace  is  designed  to  operate  with  all 

combustion air being siphoned from the outside of the building 

and all exhaust gases expelled to the outside of the building. The 

information contained in this manual pertains to all models and gas 

control systems unless otherwise noted.

 

WARNING

This unit is not for use with solid fuels

Appliance Certification 

This  fireplace  is  design  certified  in  accordance  with  American 

National Standard/CSA Standard ANSI Z.21-50/CSA 2.22 and by 

Underwriters Laboratories as a Direct Vent Gas Fireplace and shall 

be installed according to these instructions.
Consult your local building code agency, prior to installation, to ensure 

compliance with local codes-including permits and inspections.

The  fireplace,  when  installed,  must  be  electrically  grounded  in 

accordance with local codes or, in absence of local codes, with the 

National Electric Code ANSI/NFPA 70

 or Canadian Electric code, 

CSA C22.1, if an external electrical source is utilized.
These models may be installed in a bedroom or bed-sitting room 

in the U.S.A. and Canada.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment 

or accessories and repair and servicing of equipment shall be 

performed only by a qualified agency. The term “qualified agency” 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible for 

(a) the installation or replacement of gas piping or (b) the connection, 

installation, repair or servicing of equipment, who is experienced in 

such work, familiar with all precautions required and has complied 

with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by 

a licensed plumber or gas fitter in the Commonwealth of 

Massachusetts.

The installation must conform with local codes or, in the absence of 

local codes, with the 

National Fuel Gas Code ANSI Z223.1/NFPA 

54* Natural Gas and Propane Installation Code, or CSA B149.1 in 
Canada. *Available from the American National Standards Institute, 
Inc. 11 West 42nd St., New York, N.Y. 10036.

Any alteration of the original design, installed other than as 

shown  in  these  instructions  or  use  with  a  type  of  gas  not 

shown on the rating plate is the responsibility of the person 

and company making the change.

Important

All correspondence should refer to complete Model Number, Serial 

Number and type of gas.

High Altitude 

When installing this unit at an elevation above 2000 feet (in the 

United States) it may be necessary to decrease the input rating by 

changing the existing burner orifice to a smaller size. Generally, 

input should be reduced 4 percent for each 1000 feet above sea 

level. However, if the heating value of the gas has been reduced, 

this general rule may not apply. Check with local gas utility for proper 

orifice size identification.

Canadian High Altitude 

Altitude: 0-4500 feet (0-1370 m)
When installing this unit at an elevation above 4500 feet (in Canada), 

check with local authorities.
Consult your local gas utility for assistance in determining the proper 

orifice for location.

Preparation

This direct vent gas fireplace and its components are tested and 

safe when installed in accordance with this Installation Manual. 

Report to your dealer any parts damaged in shipment, specifically 

check glass condition. Do not install unit with damaged, incomplete, 

or substitute parts. Read all instructions before starting installation 

and follow these instructions carefully during installation to insure 

maximum benefit and safety. Failure to follow them will void your 

warranty and may present a fire hazard.

The warranty will be voided by, and the warranter disclaims any 

responsibility for the following actions:

•  Installation of any damaged fireplace or vent system 

component.

•  Modification of the fireplace or direct vent system.

•  Installation other than as instructed by Empire Comfort Systems, 

Inc.

•  Improper positioning of the optional decorative glass or glass 

door assembly.

•  Installation and/or use of any component part not manufactured 

or approved by manufacturer.

NOTICE:  Prior  to  operating  this  unit,  be  sure  to  clean  the 

 

interior porcelain coated liner panels and glass door with a 

soft  clean  cloth.  Due  to  normal  manufacturing  processes, 

 

fingerprints  along  with  excess  sealing  materials  may  be 

 

present and should be removed. When cleaning, do not use 

abrasives on the porcelain liners or the glass door assembly.

INTRODUCTION

 

WARNING

ANY CHANGE TO THIS FIREpLACE OR ITS CONTROLS 

CAN BE DANGEROUS.

Improper  installation  or  use  of  the  fireplace  can  cause 

serious  injury  or  death  from  fire,  burns,  explosions,  or 

carbon monoxide poisoning

Содержание DVL25FP32N-2

Страница 1: ...he information in these instruc tions are not followed exactly a fire or explo sion may result causing property damage personal injury or loss of life WARNING HOT GLASS DO NOT TOUCH NEVER WILL CAUSE B...

Страница 2: ...tion 26 27 Alternate On Off Switch Installation 28 Surround Panel Installation 29 Optional Blower Accessory Information 30 Optional Decorative Glass Placement 31 Operating Instructions 32 Standing Pil...

Страница 3: ...he glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control compartment c...

Страница 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Страница 5: ...2nd St New York N Y 10036 Any alteration of the original design installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the...

Страница 6: ...ical vent kit DVVK 4FRE Horizontal flex vent kit round cap DVVK 4RE Horizontal round termination wall thick ness up to 11 7 16 DV822 Vinyl siding kit for DVVK 4RE DVVK 4F Horizontal flex vent kit DVVK...

Страница 7: ...supply requirements for optional blower Properly framed opening size required for installation of the fireplace DV FIREPLACE DIMENSIONS MODEL A B C D E F G H I J K L M N O DVL25FP 37 1 2 26 14 1 4 10...

Страница 8: ...EDGE OF DOOR FRAME 3 MIN 3 MIN 3 MIN TOP VIEW NON COMBUSTIBLE AREA TO SIDES AND BACK OF FIREPLACE Figure 3 3 MIN CLEARANCE ABOVE VENT SYSTEM 1 MIN CLEARANCE FROM FRAMING TO VENT SYSTEM 25 MIN DISTANC...

Страница 9: ...ails in Venting Section When you install your Direct Vent Fireplace in D Room divider or E Flat on wall corner positions a minimum of 6 inches clearance must be maintained from the perpendicular wall...

Страница 10: ...dures results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the fireplace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have...

Страница 11: ...en a metal or wood panel is placed beneath the appliance 4 Install the side Framing brackets 1 per side using the pi lot holes provided behind the side flanges on the fireplace outer wrap Two setback...

Страница 12: ...Clearance Note Maintain one inch 1 of clearance around vertical vent pipe See Figure 11 For horizontal vent maintain a minimum 1 clearance to the bottom and sides of the vent and 3 clearance to combus...

Страница 13: ...16 C 14 1 16 15 5 16 D 53 1 2 60 3 8 Optional Blower Accessory The Loft fireplace may be equipped with an optional FBB8 blower accessory See page 38 The blower accessory may be installed at any time...

Страница 14: ...cal Building Codes before beginning the installation WARNING THIS GAS FIREPLACE AND VENT ASSEMBLY MUST BE VENTED DIRECTLY TO THE OUTSIDEAND MUST NEVER BE ATTACHED TO A CHIMNEY SERVING A SEPARATE SOLID...

Страница 15: ...ing out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold weather...

Страница 16: ...does not apply if the 45 degree elbows are installed on the vertical part of the vent system Reduce 3 for every 90 elbow Example According to the chart the maximum horizontal vent length is 20 and if...

Страница 17: ...evel a snorkel kit is recommended It allows installation depth down to 7 178 mm below grade level The 7 178 mm is measured from the center of the horizontal vent pipe as it penetrates through the wall...

Страница 18: ...nued Positioning the Fireplace Determine the exact position of the appliance so the direct vent termination will be centered if possible between two 2 studs This will avoid any extra framing All vent...

Страница 19: ...re 25 Figure 26 EXAMPLES TOP VENT RUN 24 MINIMUM CLEARANCE TO COMBUSTIBLES 24 H2 H1 V1 Example H2 2ft 2 90 90 6ft H 8ft V 15ft 3 ft 914 mm H3 1 ft 305mm 4 ft 122mm 6 ft 1 83M 21 ft 6 4M 10 ft 3M V 21f...

Страница 20: ...lace in such a way that minimizes the number of offsets and horizontal vent length Since it is very important that the venting system maintain its balance between the combustion air intake and the flu...

Страница 21: ...center line of the regulator I clearance to service regulator vent outlet 6 feet 1 89 m minimum J clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appl...

Страница 22: ...f each starting outer pipe line up rotate pipe section clockwise 90 approximately 3 inches The vent pipe is now locked together Continue adding components per the pre planned vent system configuration...

Страница 23: ...ANCE TO COMBUSTIBLES FROM VERTICAL VENT 12 MIN 304 8mm CLEARANCE TO COMBUSTIBLES 3 MIN 76 2mm CLEARANCE TO COMBUSTIBLES Figure 30 Installing Firestops Firestops are required for safety whenever the ve...

Страница 24: ...r any obstructions such as wiring or plumbing runs Reposition the appliance and vent system if necessary to accommodate ceiling joists and or obstructions Cut a 10 inch x 10 inch hole through the ceil...

Страница 25: ...tside edge too so as to make a seal to the exterior wall NOTE Wood screws can and should be replaced with appropriate fasteners for use on stucco brick concrete or other types of siding CAUTION Ifexte...

Страница 26: ...s holes These components should immediately be replaced 2 Remove the cap and shine a flashlight down the vent Remove any bird nests or other foreign material 3 Check for evidence of excessive condensa...

Страница 27: ...daptoronfireplace Replace the horizontal and vertical pipe lengths elbows and horizontal or vertical termination kit All vent system components lock into place by sliding the concentric pipe section w...

Страница 28: ...f switch located on the front of the control module tray 3 Run the low voltage alternate switch wires over to the right or left surround panel Then secure the wires with wire clips provided See Figure...

Страница 29: ...TO SIDE FLANGES ON INSERT BACK SIDE NOTE INSTALL SURROUND ASSEMBLY SO THAT THE REAR FLANGE OF THE TOP PANEL SETS OVER THE TOP EDGE OF THE TOP SUPPORT BRACKET CENTER SURROUND LEFT TO RIGHT THEN SWING...

Страница 30: ...ollows From a cold start the temperature activated fan control switch will normally take 5 10 minutes to heat up and energize the blower Once the blower is energized adjust the blower speed control as...

Страница 31: ...only be performed after the DVL Fireplace has been fully installed secured and tested for leaks If operating the burner with a Remote Control make sure all batteries are installed and that the burner...

Страница 32: ...our pilot flame to operate an additional one 1 to two 2 minutes before you turn the gas control knob from the PILOT position to the ON position This time period allows the millivolts electrical curren...

Страница 33: ...ed setting THERMOCUPLE ELECTRODE THERMOPILE PILOT FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage pe...

Страница 34: ...VE WILL BE DESTROYED WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROL WIRING ERRORS CAN CAUSE IM PROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING For Standin...

Страница 35: ...he pilot flame Be sure the wire connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt m...

Страница 36: ...ded that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3 The gas valve has inlet and outlet pressure taps as sh...

Страница 37: ...ION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment alt...

Страница 38: ...ormation Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or lo...

Страница 39: ...uctions on page 38 and Wiring Diagram on page 37 Troubleshooting Before proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and...

Страница 40: ...e wire harness 4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness...

Страница 41: ...ase and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure...

Страница 42: ...manufacturing processes fingerprints along with excess sealing materials may be present and should be removed When cleaning do not use abrasives on the porcelain liners or the glass door assembly Clea...

Страница 43: ...el Number Float DF 25 33 S BL HP SS Black Hammered Pewter Stainless Steal Must also use 4 sided surround 4 Sided Surround DS 25 33 66BL Black Manhattan DF 25 33 N BL HP Black Hammered Pewter Must also...

Страница 44: ...5 17155 17155 FLUE OUTLET ASSEMBLY 5 M163 M163 M163 M163 GASKET FLUE CONNECTOR 6 16223 27718 16223 27718 SPRING RETAINER ASSEMBLY 7 30577 30577 30577 30577 NAILING FLANGE 8 R10854 R10854 R10854 R10854...

Страница 45: ...45mm P182 55 P208 1 45mm ORIFICE LP GAS 26 R7624 R7624 R7624 R7624 AIR SHUTTER 27 R10732 R10879 R10732 R10879 TUBE BURNER 28 11269 11269 11269 11269 GAS LINE BRACKET 29 28067 28067 28067 28067 BURNER...

Страница 46: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 47: ...iance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verif...

Страница 48: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: