Installation of Vertical Inlet Baffle

The vertical inlet baffle is to be used only in a completely vertical vent 

installation. The vertical inlet baffle can be used when the vertical 

vent rise is between 10 feet and 40 feet. To maintain the yellow 

flame in the main burner, purchase Vertical Inlet baffle, DVF-139 

from your Empire Comfort Systems, Inc. distributor or dealer for 

Simpson Duravent only.

In a vertical vent rise the flame on the main burner can be reduced 

due to the drawing action from the flue exhaust pipe and the air inlet 

pipe. A decrease in the height or the appearance of the yellow flame 

may occur when the vertical vent rise is between 10 feet and 40 feet. 

To enhance the yellow flame on the main burner, the vertical inlet 

baffle can be attached to the direct vent high wind vertical top.

Please  use  the  following  steps  to  install  the  vertical  inlet 

baffle.

1.  Place the vertical inlet baffle over the exterior of the air inlet 

openings on the direct vent high wind vertical top.

2.  There are three sections of air openings on the exterior of the 

air inlet pipe. 

  To achieve the 

maximum

 amount of yellow flame the vertical 

inlet baffle will cover-up three sections of air openings. 

  To achieve the 

minimum

 amount of yellow flame the vertical 

inlet baffle will cover-up one section of air openings.

3.  Attach vertical inlet baffle to the direct vent high wind vertical 

top with (2) 3/8" hex-head screws provided with vertical inlet 

baffle.

4.  Installation of vertical inlet baffle is completed.

parts List

Description

Part 

Number

Quantity 

Supplied

Vertical Inlet Baffle

DVF-139

1

3/8" Hex-Head Screw

R-2656

2

Reassembly and Resealing Vent Pipe System

Attach vent pipe to inlet and outlet vent adaptor on fireplace.  Replace 

the horizontal and vertical pipe lengths, elbows and horizontal or 

vertical termination kit.
All vent system components lock into place by sliding the concentric 

pipe section with four (4) equally spaced interior beads onto the 

appliance collar or previously installed component end with four 

(4) equally spaced indented sections. When the internal beads of 

each starting outer pipe line up, rotate pipe section clockwise 90° 

(approximately 3 inches). The vent pipe is now locked together.

Continue replacing components per the vent system configuration. 

Be certain that each succeeding vent component is securely fitted 

and locked into the preceding component in the vent system.

Reassembly and Resealing Gas Accumulation Relief System

Glass Frame Assembly and Combustion Chamber

Whenever the glass frame assembly  is pivoted open by a delayed 

ignition in the main burner, the glass frame assembly gaskets and 

combustion chamber must be examined by a qualified service person 

for damage. All damaged gaskets on the glass frame assembly and 

combustion chamber must be replaced by a qualified service person. 

If damage occurs to the combustion chamber, it must be replaced 

by a qualified service person. Contact Empire Comfort Systems, 

Inc. for replacement parts.

Vertical Through the Roof Applications (Figure 38)

Your Gas Fireplace has been approved for:

a)  Vertical installations up to 40 feet in height.

b) Two sets of 45 degree elbow offsets within these vertical 

installations. From 0 to a maximum of 8 ft. a vent pipe can be 

used between elbows.

c)  Wall straps must be used to support offset pipe every 4'. 

This application will require that you first determine the roof pitch 

and use the appropriate venting components.

C

L

24” MINIMUM

CLEARANCE TO

COMBUSTIBLES;

NATURAL OR

MAN MADE.

TYPICAL ROOF

SUPPORT

TYPICAL JOIST

SUPPORT

40’

(12.19 M)

MAXIMUM

8’ (2.44 M)

MAXIMUM

8’ (2.44 M)

MAXIMUM

45°

45°

Figure 38

VERTICAL TERMINATION (continued)

Содержание DVL25FP32N-2

Страница 1: ...he information in these instruc tions are not followed exactly a fire or explo sion may result causing property damage personal injury or loss of life WARNING HOT GLASS DO NOT TOUCH NEVER WILL CAUSE B...

Страница 2: ...tion 26 27 Alternate On Off Switch Installation 28 Surround Panel Installation 29 Optional Blower Accessory Information 30 Optional Decorative Glass Placement 31 Operating Instructions 32 Standing Pil...

Страница 3: ...he glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control compartment c...

Страница 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Страница 5: ...2nd St New York N Y 10036 Any alteration of the original design installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the...

Страница 6: ...ical vent kit DVVK 4FRE Horizontal flex vent kit round cap DVVK 4RE Horizontal round termination wall thick ness up to 11 7 16 DV822 Vinyl siding kit for DVVK 4RE DVVK 4F Horizontal flex vent kit DVVK...

Страница 7: ...supply requirements for optional blower Properly framed opening size required for installation of the fireplace DV FIREPLACE DIMENSIONS MODEL A B C D E F G H I J K L M N O DVL25FP 37 1 2 26 14 1 4 10...

Страница 8: ...EDGE OF DOOR FRAME 3 MIN 3 MIN 3 MIN TOP VIEW NON COMBUSTIBLE AREA TO SIDES AND BACK OF FIREPLACE Figure 3 3 MIN CLEARANCE ABOVE VENT SYSTEM 1 MIN CLEARANCE FROM FRAMING TO VENT SYSTEM 25 MIN DISTANC...

Страница 9: ...ails in Venting Section When you install your Direct Vent Fireplace in D Room divider or E Flat on wall corner positions a minimum of 6 inches clearance must be maintained from the perpendicular wall...

Страница 10: ...dures results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the fireplace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have...

Страница 11: ...en a metal or wood panel is placed beneath the appliance 4 Install the side Framing brackets 1 per side using the pi lot holes provided behind the side flanges on the fireplace outer wrap Two setback...

Страница 12: ...Clearance Note Maintain one inch 1 of clearance around vertical vent pipe See Figure 11 For horizontal vent maintain a minimum 1 clearance to the bottom and sides of the vent and 3 clearance to combus...

Страница 13: ...16 C 14 1 16 15 5 16 D 53 1 2 60 3 8 Optional Blower Accessory The Loft fireplace may be equipped with an optional FBB8 blower accessory See page 38 The blower accessory may be installed at any time...

Страница 14: ...cal Building Codes before beginning the installation WARNING THIS GAS FIREPLACE AND VENT ASSEMBLY MUST BE VENTED DIRECTLY TO THE OUTSIDEAND MUST NEVER BE ATTACHED TO A CHIMNEY SERVING A SEPARATE SOLID...

Страница 15: ...ing out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold weather...

Страница 16: ...does not apply if the 45 degree elbows are installed on the vertical part of the vent system Reduce 3 for every 90 elbow Example According to the chart the maximum horizontal vent length is 20 and if...

Страница 17: ...evel a snorkel kit is recommended It allows installation depth down to 7 178 mm below grade level The 7 178 mm is measured from the center of the horizontal vent pipe as it penetrates through the wall...

Страница 18: ...nued Positioning the Fireplace Determine the exact position of the appliance so the direct vent termination will be centered if possible between two 2 studs This will avoid any extra framing All vent...

Страница 19: ...re 25 Figure 26 EXAMPLES TOP VENT RUN 24 MINIMUM CLEARANCE TO COMBUSTIBLES 24 H2 H1 V1 Example H2 2ft 2 90 90 6ft H 8ft V 15ft 3 ft 914 mm H3 1 ft 305mm 4 ft 122mm 6 ft 1 83M 21 ft 6 4M 10 ft 3M V 21f...

Страница 20: ...lace in such a way that minimizes the number of offsets and horizontal vent length Since it is very important that the venting system maintain its balance between the combustion air intake and the flu...

Страница 21: ...center line of the regulator I clearance to service regulator vent outlet 6 feet 1 89 m minimum J clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appl...

Страница 22: ...f each starting outer pipe line up rotate pipe section clockwise 90 approximately 3 inches The vent pipe is now locked together Continue adding components per the pre planned vent system configuration...

Страница 23: ...ANCE TO COMBUSTIBLES FROM VERTICAL VENT 12 MIN 304 8mm CLEARANCE TO COMBUSTIBLES 3 MIN 76 2mm CLEARANCE TO COMBUSTIBLES Figure 30 Installing Firestops Firestops are required for safety whenever the ve...

Страница 24: ...r any obstructions such as wiring or plumbing runs Reposition the appliance and vent system if necessary to accommodate ceiling joists and or obstructions Cut a 10 inch x 10 inch hole through the ceil...

Страница 25: ...tside edge too so as to make a seal to the exterior wall NOTE Wood screws can and should be replaced with appropriate fasteners for use on stucco brick concrete or other types of siding CAUTION Ifexte...

Страница 26: ...s holes These components should immediately be replaced 2 Remove the cap and shine a flashlight down the vent Remove any bird nests or other foreign material 3 Check for evidence of excessive condensa...

Страница 27: ...daptoronfireplace Replace the horizontal and vertical pipe lengths elbows and horizontal or vertical termination kit All vent system components lock into place by sliding the concentric pipe section w...

Страница 28: ...f switch located on the front of the control module tray 3 Run the low voltage alternate switch wires over to the right or left surround panel Then secure the wires with wire clips provided See Figure...

Страница 29: ...TO SIDE FLANGES ON INSERT BACK SIDE NOTE INSTALL SURROUND ASSEMBLY SO THAT THE REAR FLANGE OF THE TOP PANEL SETS OVER THE TOP EDGE OF THE TOP SUPPORT BRACKET CENTER SURROUND LEFT TO RIGHT THEN SWING...

Страница 30: ...ollows From a cold start the temperature activated fan control switch will normally take 5 10 minutes to heat up and energize the blower Once the blower is energized adjust the blower speed control as...

Страница 31: ...only be performed after the DVL Fireplace has been fully installed secured and tested for leaks If operating the burner with a Remote Control make sure all batteries are installed and that the burner...

Страница 32: ...our pilot flame to operate an additional one 1 to two 2 minutes before you turn the gas control knob from the PILOT position to the ON position This time period allows the millivolts electrical curren...

Страница 33: ...ed setting THERMOCUPLE ELECTRODE THERMOPILE PILOT FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage pe...

Страница 34: ...VE WILL BE DESTROYED WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROL WIRING ERRORS CAN CAUSE IM PROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING For Standin...

Страница 35: ...he pilot flame Be sure the wire connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt m...

Страница 36: ...ded that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3 The gas valve has inlet and outlet pressure taps as sh...

Страница 37: ...ION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment alt...

Страница 38: ...ormation Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or lo...

Страница 39: ...uctions on page 38 and Wiring Diagram on page 37 Troubleshooting Before proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and...

Страница 40: ...e wire harness 4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness...

Страница 41: ...ase and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure...

Страница 42: ...manufacturing processes fingerprints along with excess sealing materials may be present and should be removed When cleaning do not use abrasives on the porcelain liners or the glass door assembly Clea...

Страница 43: ...el Number Float DF 25 33 S BL HP SS Black Hammered Pewter Stainless Steal Must also use 4 sided surround 4 Sided Surround DS 25 33 66BL Black Manhattan DF 25 33 N BL HP Black Hammered Pewter Must also...

Страница 44: ...5 17155 17155 FLUE OUTLET ASSEMBLY 5 M163 M163 M163 M163 GASKET FLUE CONNECTOR 6 16223 27718 16223 27718 SPRING RETAINER ASSEMBLY 7 30577 30577 30577 30577 NAILING FLANGE 8 R10854 R10854 R10854 R10854...

Страница 45: ...45mm P182 55 P208 1 45mm ORIFICE LP GAS 26 R7624 R7624 R7624 R7624 AIR SHUTTER 27 R10732 R10879 R10732 R10879 TUBE BURNER 28 11269 11269 11269 11269 GAS LINE BRACKET 29 28067 28067 28067 28067 BURNER...

Страница 46: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 47: ...iance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verif...

Страница 48: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: