37742-0-1116
Page 33
DVVK-5F FLEX VENT INSTRUCTIONS
9. Prior to making the vent connections, apply high temperature
sealant (1000°F min.) to the vent connections before securing
with the band clamps provided. Note: the flue pipe end without
the adapter is to be installed to the Termination Cap.
10. Apply sealant to the outside of the flue pipe adapter and
connect to the flex flue pipe. Then insert the adapter into the
fireplace flue. Secure flue adapter to the fireplace flue with a
minimum of two screws provided.
See Figure 70.
11. Attach the Outer Vent pipe to the 8” diameter collar on the
fireplace with a large band clamp provided. Sealant may also
be used on the outer vent connections.
12. Check all vent connections for tightness. Make sure horizontal
venting has the proper rise and combustible clearances
required. Refer to venting charts in fireplace instruction manual.
6” PIPE
8” DIAMETER FLEX
VENT PIPE
5” DIAMETER FLEX
FLUE PIPE
5” DIAMETER
FLUE ADAPTOR
COLLAR
8” DIAMETER
FIREPLACE
INLET COLLAR
BAND CLAMP
APPLY HIGH
TEMPERATURE
SEALANT
Figure 70
Figure 71
Содержание DVCT36CFP95-1
Страница 37: ...37742 0 1116 Page 37 LOG AND EMBER PLACEMENT 1 Place Ember Bed A onto burner pins 3 and 4 ...
Страница 38: ...37742 0 1116 Page 38 LOG PLACEMENT 2 Place Log B onto burner pins 1 and 2 ...
Страница 43: ...37742 0 1116 Page 43 LOG PLACEMENT 7 Place Log E onto burner pin 5 and the pin on Ember Bed A ...
Страница 44: ...37742 0 1116 Page 44 LOG PLACEMENT 8 Place Log F onto the left pin on Log B and the pin on Log E ...
Страница 46: ...37742 0 1116 Page 46 LOG PLACEMENT 10 Place Log H onto the rear pin on Log F and angle down to Log C ...
Страница 50: ...37742 0 1116 Page 50 LOG PLACEMENT 14 Place Log L over the front burner tube and on Ember Bed A ...
Страница 51: ...37742 0 1116 Page 51 LOG PLACEMENT 15 Place Log N over the front of the burner tube and on Ember Bed A ...
Страница 55: ...37742 0 1116 Page 55 THIS PAGE IS INTENTIALLY LEFT BLANK ...