40’
(12.19M)
MAX
24” MINIMUM
CLEARANCE TO
COMBUSTIBLES
NATURAL OR
MAN MADE
8’ (2.44M)
MAX
8’ (2.44M)
MAX
45°
45°
Figure 65
GENERIC MODEL SHOWN
The vertical termination cap for this fireplace must not be any
closer than 24-in. to any other vent termination or chimney of any
type.
(See Figure 66)
Figure 66
Vertical Through the Roof Applications
Your Gas Fireplace has been approved for:
a) Vertical installations up to 40 feet in height.
b) Two sets of 45 degree elbow offsets within these vertical
installations. From 0 to a maximum of 8 ft. a vent pipe can be
used between elbows.
c) Wall straps must be used to support offset pipe every 4’.
This application will require that you first determine the roof pitch
and use the appropriate venting components.
OFFSET CHART
RISE
OFFSET
SIZE
5” X 8”
ELBOW
DEGREES
CHIMNEY
SECTION
OFFSET
INCHES
RISE
INCHES
45°
0”
5-5/8”
15-3/8”
45°
6”
8-7/8”
18-3/8”
45°
9”
10-7/8”
20-5/8”
45°
12”
13”
22-5/8”
45°
24”
21-3/8”
31-1/8”
45°
36”
29-7/8”
39-3/8”
45°
36”
28-7/8”
39-3/8”
45°
48”
38-1/4”
47-7/8”
Figure 67
VERTICAL TERMINATION
Содержание DVCT36CFP95-1
Страница 37: ...37742 0 1116 Page 37 LOG AND EMBER PLACEMENT 1 Place Ember Bed A onto burner pins 3 and 4 ...
Страница 38: ...37742 0 1116 Page 38 LOG PLACEMENT 2 Place Log B onto burner pins 1 and 2 ...
Страница 43: ...37742 0 1116 Page 43 LOG PLACEMENT 7 Place Log E onto burner pin 5 and the pin on Ember Bed A ...
Страница 44: ...37742 0 1116 Page 44 LOG PLACEMENT 8 Place Log F onto the left pin on Log B and the pin on Log E ...
Страница 46: ...37742 0 1116 Page 46 LOG PLACEMENT 10 Place Log H onto the rear pin on Log F and angle down to Log C ...
Страница 50: ...37742 0 1116 Page 50 LOG PLACEMENT 14 Place Log L over the front burner tube and on Ember Bed A ...
Страница 51: ...37742 0 1116 Page 51 LOG PLACEMENT 15 Place Log N over the front of the burner tube and on Ember Bed A ...
Страница 55: ...37742 0 1116 Page 55 THIS PAGE IS INTENTIALLY LEFT BLANK ...