Locating Wall Opening

The furnace is to be located on an outside wall. Locate wall studs so 

that wall opening will be located between wall studs. The furnace 

is 16 inches in width and normal 16 inches on center studs will 

not allow the furnace to be recessed into the wall unless a stud is 

repositioned. The wall opening required as shown in Figure 5 is a 

diameter of 7 1/2 inches.
A template is provided in furnace carton for positioning furnace 

on the wall. Also, refer to Figure 5 for positioning the furnace on 

wall and for locating gas line connection.

Installing Optional Side Outlets

Side outlet register, SOR-1 may be installed on one or both sides 

of the furnace at the required clearances of 18 inches to adjacent 

wall or combustible material as shown in Figure 4. 

  1.  Locate and cut the 5 1/2" square opening in the cabinet side 

using the template from the kit, exposing the inner liner 

knock-out.

  2.  Remove the knock-out. 

  3.  Place the register on the 5 1/2" opening with the louvers set 

for the desired direction and mark the mounting holes using 

the register as a template. 

  4.  Drill two (2) 1/8" diameter holes in cabinet side and fasten 

the register in place with two (2) 10 x 1" screws provided. 

Side outlet kit, 10" boot assembly with register, SOK-1 for warm 

air discharge into an adjoining room may be installed on either side 

of the furnace at the required clearance of 4 inches to adjacent wall 

as shown in Figure 7. 
  1.  Locate and cut the 5 1/2" square opening in the cabinet side 

using the template from the kit, exposing the inner liner 

knock-out.

  2.  Remove the knock-out. 

  3.  Using the inner and outer boots as hole templates, mark 

and drill eight (8) 1/8" diameter holes in the inner liner and 

cabinet side.

  4.  Using Figure 7 locate and cut a 6 3/4" square opening through 

walls. 

  5.  Prepare wall opening for the vent-air intake system (see 

Locating Wall Opening

). 

  6.  With furnace in place, after checking alignment of side outlet 

opening in wall and furnace, place the 9 3/8" x 9 3/8" side 

outlet wall plate over outer boot, pass the outer boot through 

the wall and attach side outlet wall plate to furnace side of 

wall with two (2) 10 x 1" screws provided. 

  7.  Fasten outer boot to the cabinet side with four (4) 8 x 1/4" 

screws provided. 

  8.  Position and attach inner boot to inner liner with four (4) 8 

x 1/4" screws provided. 

  9.  Locate the register with its louvers positioned for the desired 

air discharge direction and mark the mounting holes using 

the register as a template. 

  10.  Drill two (2) 1/8" diameter holes in the wall and fasten the 

register in place with two (2) 10 x 1" screws provided.

Figure 5

                       Figure 6                      Figure 7

INSTALLATION INSTRUCTIONS

Содержание DV-55T-1

Страница 1: ...eath or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas sup...

Страница 2: ...r Massachusetts 5 Introduction 6 Specifications 6 Gas Supply 7 8 Clearances 8 Installation Instructions 9 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Wiring 14 Service and Maintenance Suggestions 15 How to Order Repair Parts 16 Parts List 16 Parts View 17 Service Notes 18 19 TABLE OF CONTENTS ...

Страница 3: ... control compartments burners and circulating air passageways of the appliance be kept clean DO NOT put anything around the furnace that will obstruct the flow of combustion and ventilation air DOkeeptheapplianceareaclearandfreefromcombustible material gasoline and other flammable vapors and liquids DO examine venting system periodically and replace damaged parts DO make a periodic visual check of p...

Страница 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstal...

Страница 5: ...quiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall ...

Страница 6: ...tilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term qualified agency means any indi vidual firm corporation or company which either in person or through a representative is engaged in and is responsible for a the installation or replacement of gas piping or b the connection installation repair or servicing of equipment who i...

Страница 7: ...e to check for leaks Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be in...

Страница 8: ...from the center of the vent cap to the nearest outside corner or obstruction is 24 inches The vent terminal of a direct vent appliance with an input over 50 000 BTU per hour shall be located at least 12 inches from any opening through which flue gases could enter a building The bot tom of the vent terminal and the air intake shall be located at least 12 inches above grade WARNING The nearest point ...

Страница 9: ...provided Side outlet kit 10 boot assembly with register SOK 1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches to adjacent wall as shown in Figure 7 1 Locate and cut the 5 1 2 square opening in the cabinet side using the template from the kit exposing the inner liner knock out 2 Remove the knock out 3 Using the inner...

Страница 10: ...left and right side panels A three prong grounding plug assembly is located within the control compartment bottom of the furnace Please remove 7 8 knockout from appropriate side panel when routing plug assembly to an electrical outlet Installation of Three prong Grounding Plug Assembly 1 Disconnect nylon cap on 3 plug assembly from nylon plug on wiring harness Remove 3 plug assembly from control c...

Страница 11: ...isturbs the wind on one side of the air inlet section will result in back pressure on the flue section smothering the flame and eventual pilot outage When the vent cap is to be installed on siding or it appears that a projection within 6 of any side of the air inlet section could shield the air inlet section the entire vent should be supported away from the wall at least the distance of the projecti...

Страница 12: ...electric power to the appliance 15 Set thermostat to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORELIGHTINGsmellallaroundtheap...

Страница 13: ...v ing the burner door from the combustion chamber remove rear burner pilot burner and front burner With front and rear burners removed from furnace force water into the ribbon ports and dry with air pressure The correct pilot flame Figure 12 will be blue extending past the thermocouple The flame will surround the thermocouple just below the tip Natural gas pilots require adjusting when the inlet gas...

Страница 14: ...can be purchased plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw With this wire completing the ground the appliance cord plug can bepluggedintotheadapterandbeelectricallygrounded A7 8 hole is provided in the junction box for use with a conduit connector if local codes require this type of protection Thermostat Installation The thermostat should be ins...

Страница 15: ...nace is first installed or was off all summer the pilot flame may be too lean to ignite on the first few trials Turn the controlvalveknobtopilotpositionanddepresstheredresetbutton Holding the button down continually to bleed the line 1 Use lighter rod to light pilot with a match 2 Use the piezo ignitor at 30 second intervals until it lights If Electrode Does Not Produce Spark 1 Check wire connections...

Страница 16: ... a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Furnace Model Number Part Description Furnace Serial Number Part Number Type of Gas Propane or Natural Do not order bolts s...

Страница 17: ...13118 7 0408 Page 17 PARTS VIEW ...

Страница 18: ...13118 7 0408 Page 18 SERVICE NOTES ...

Страница 19: ...13118 7 0408 Page 19 SERVICE NOTES ...

Страница 20: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Отзывы: