Empire Heating Systems DV-55T-1 Скачать руководство пользователя страница 16

13118-7-0408

Page 16

PLEASE NOTE: 

When ordering parts, it is very important that 

part number

 and 

description

 of part coincide.

Index 

Part

 No. 

Number 

Description

 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

  1 

11762 

OUTER CASING TOP

  2 

R-618 

MOTOR MOUNT - 4 REQUIRED

  3 

11764 

MOTOR MOUNTING BAR -  2 REQ'D

  4 

M-147 

GASKET - 2 REQUIRED

  5 

R-619 

MOTOR

  6 

11787 

FAN BLADE

  7 

11766 

FAN HOUSING

  8 

DV-558 

FRONT PANEL-  UPPER

  9 

11759 

SIDE PANEL - 2 REQUIRED

  10 

DV-613 

INNER SHIELD - RIGHT

  11 

13057 

OUTLET TUBE - INNER ASSEMBLY 

(INCLUDES 12 &13)

  12 

M-177 

GASKET - OUTLET COLLAR

  13 

13104 

OUTLET TUBE - INNER WELDED 

ASSEMBLY

  14 

13062 

INNER TUBE - INNER ASSEMBLY 

(INCLUDES 15 & 16)

  15 

M-178 

GASKET - INLET COLLAR

  16 

13106 

INLET TUBE - INNER WELDED 

ASSEMBLY

  17 

13064 

INLET TUBE - OUTER ASSEMBLY

  18 

13059 

OUTLET TUBE - OUTER ASSEMBLY

  19 

13053 

VENT CAP ASSEMBLY WELDED

  20 

DV-1387 

AIR DROP WELDED ASSEMBLY

  21 

M-176 

GASKET - FLUE OUTLET FLANGE

  22 

13113 

COMBUSTION CHAMBER WELDED 

ASSEMBLY

  23 

R-1536 

BUSHING

  24 

11765 

SWITCH COMPARTMENT

  25 

R-630 

LIMIT CONTROL

  26 

R-1941 

FAN CONTROL

  27 

DV-832 

SWITCH COMPARTMENT COVER

  28 

DV-562 

FRONT PANEL - LOWER

  29 

DV-826 

REAR BURNER ASSEMBLY

  30 

R-685 

THERMOCOUPLE

  31 

R-622-L 

PILOT WITH ORIFICE - LPG GAS 

  31 

R-622-N 

PILOT WITH ORIFICE - NAT GAS 

Index 

Part

 No. 

Number 

Description

Parts can be ordered

 only

 through your 

service person or dealer.

 For best results, the 

service person or dealer

 should order parts through 

the distributor. Parts can be shipped directly to the 

service person/dealer

.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your 

equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the following appropriate 

illustration and list. Be sure to give all this information.
Furnace Model Number

    Part Description 

Furnace Serial Number 

 

Part Number 

Type of Gas (Propane or Natural) 
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 
Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc. 

Nine Eighteen Freeburg Ave.  Belleville, IL 62220-2623

  32 

DV-808 

PILOT TUBING

  33 

DV-824 

FRONT BURNER ASSEMBLY

  34 

P-88-41 

ORIFICE - NAT GAS  - 2 REQUIRED

  34 

P-88-53 

ORIFICE - LPG GAS  - 2 REQUIRED

  35 

DV-687 

MANIFOLD

  36 

M-148 

GASKET - MANIFOLD

  37 

M-155 

GASKET-OBSERVATION HOLE COVER

  38 

DV-781 

LIGHTING HOLE COVER ASSEMBLY

  39 

DV-064 

COVER PLATE-OBSERVATION HOLE

  40 

DV-775 

SEAL BRACKET

  41 

M-147 

GASKET - TUBING SEAL

  42 

DV-622 

BURNER DOOR - NAT GAS 

  42 

DV-973 

BURNER DOOR - LPG GAS 

  43 

DV-779 

GASKET - BURNER DOOR

  44 

P-112 

MANIFOLD UNION

  45 

R-5655 

GAS VALVE - LPG GAS

  45 

R-2148 

GAS VALVE - NAT GAS 

  46 

UH-810 

TRANSFORMER MOUNTING BRACKET

  47 

R-1995 

TRANSFORMER

  48 

UH-451 

JUNCTION BOX COVER

  49 

11760 

OUTER CASING BOTTOM

  50 

R-1515 

BUSHING

  51 

R-2708 

PIEZO IGNITOR

  52 

DV-571 

CONTROL COMPARTMENT DIVIDER

  53 

DV-671 

MANIFOLD SUPPORT

  54 

DV-765 

GASKET - CHAMBER AIR INLET (TOP & 

BOTTOM) - 2 REQUIRED

  55 

DV-764 

GASKET - CHAMBER AIR INLET (SIDES) 

-   2 REQUIRED

  56 

R-690-B 

CORD SET

  57 

R-1404 

BUSHING

  58 

DV-614 

INNER SHIELD - LEFT

NOT SHOWN  R-9832 

WIRING ASSEMBLY UPPER

NOT SHOWN  R-9833 

WIRING ASSEMBLY LOWER

NOT SHOWN  R-6389 

THERMOSTAT

NOT SHOWN  R-734 

LIGHTER ROD

HOW TO ORDER REPAIR PARTS

PARTS LIST

Содержание DV-55T-1

Страница 1: ...eath or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas sup...

Страница 2: ...r Massachusetts 5 Introduction 6 Specifications 6 Gas Supply 7 8 Clearances 8 Installation Instructions 9 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Wiring 14 Service and Maintenance Suggestions 15 How to Order Repair Parts 16 Parts List 16 Parts View 17 Service Notes 18 19 TABLE OF CONTENTS ...

Страница 3: ... control compartments burners and circulating air passageways of the appliance be kept clean DO NOT put anything around the furnace that will obstruct the flow of combustion and ventilation air DOkeeptheapplianceareaclearandfreefromcombustible material gasoline and other flammable vapors and liquids DO examine venting system periodically and replace damaged parts DO make a periodic visual check of p...

Страница 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstal...

Страница 5: ...quiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall ...

Страница 6: ...tilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term qualified agency means any indi vidual firm corporation or company which either in person or through a representative is engaged in and is responsible for a the installation or replacement of gas piping or b the connection installation repair or servicing of equipment who i...

Страница 7: ...e to check for leaks Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be in...

Страница 8: ...from the center of the vent cap to the nearest outside corner or obstruction is 24 inches The vent terminal of a direct vent appliance with an input over 50 000 BTU per hour shall be located at least 12 inches from any opening through which flue gases could enter a building The bot tom of the vent terminal and the air intake shall be located at least 12 inches above grade WARNING The nearest point ...

Страница 9: ...provided Side outlet kit 10 boot assembly with register SOK 1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches to adjacent wall as shown in Figure 7 1 Locate and cut the 5 1 2 square opening in the cabinet side using the template from the kit exposing the inner liner knock out 2 Remove the knock out 3 Using the inner...

Страница 10: ...left and right side panels A three prong grounding plug assembly is located within the control compartment bottom of the furnace Please remove 7 8 knockout from appropriate side panel when routing plug assembly to an electrical outlet Installation of Three prong Grounding Plug Assembly 1 Disconnect nylon cap on 3 plug assembly from nylon plug on wiring harness Remove 3 plug assembly from control c...

Страница 11: ...isturbs the wind on one side of the air inlet section will result in back pressure on the flue section smothering the flame and eventual pilot outage When the vent cap is to be installed on siding or it appears that a projection within 6 of any side of the air inlet section could shield the air inlet section the entire vent should be supported away from the wall at least the distance of the projecti...

Страница 12: ...electric power to the appliance 15 Set thermostat to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORELIGHTINGsmellallaroundtheap...

Страница 13: ...v ing the burner door from the combustion chamber remove rear burner pilot burner and front burner With front and rear burners removed from furnace force water into the ribbon ports and dry with air pressure The correct pilot flame Figure 12 will be blue extending past the thermocouple The flame will surround the thermocouple just below the tip Natural gas pilots require adjusting when the inlet gas...

Страница 14: ...can be purchased plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw With this wire completing the ground the appliance cord plug can bepluggedintotheadapterandbeelectricallygrounded A7 8 hole is provided in the junction box for use with a conduit connector if local codes require this type of protection Thermostat Installation The thermostat should be ins...

Страница 15: ...nace is first installed or was off all summer the pilot flame may be too lean to ignite on the first few trials Turn the controlvalveknobtopilotpositionanddepresstheredresetbutton Holding the button down continually to bleed the line 1 Use lighter rod to light pilot with a match 2 Use the piezo ignitor at 30 second intervals until it lights If Electrode Does Not Produce Spark 1 Check wire connections...

Страница 16: ... a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Furnace Model Number Part Description Furnace Serial Number Part Number Type of Gas Propane or Natural Do not order bolts s...

Страница 17: ...13118 7 0408 Page 17 PARTS VIEW ...

Страница 18: ...13118 7 0408 Page 18 SERVICE NOTES ...

Страница 19: ...13118 7 0408 Page 19 SERVICE NOTES ...

Страница 20: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Отзывы: