WARRANtY

Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods 

specified below.  Space heating products must be installed by a qualified technician and must be maintained and operated safely, in 

accordance with the instructions in the owner’s manual.  This warranty applies to the original purchaser only and is not transferable.  All 

warranty repairs must be accomplished by a qualified gas appliance technician.

Limited Ten-Year Parts Warranty – Combustion Chamber

     Empire promises to the owner that if the combustion chamber (see parts list) fails because of defective workmanship or material with 

ten years from the date of purchase, Empire will repair or replace at Empire’s option.

Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts

 

Should any remote control, thermostat, accessory, or other part fail because of defective workmanship within one year from 

the date of purchase, Empire will repair or replace at Empire’s option.

Duties Of The Owner

 

The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap

-

pliance.

 

A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty period.

 

Ready access to the appliance for service.

What Is Not Covered

 

Damages that might result from the use, misuse, or improper installation of this appliance.

 

Travel, diagnostic costs and freight charges on warranted parts to and from the factory.

 

Claims that do not involve defective workmanship or materials.

 

Unauthorized service or parts replacements.

 

Removal and reinstallation cost.

 

Inoperable due to improper or lack of maintenance.

How To Get Service

 

To make a claim under this warranty, please have your receipt available and contact your installing dealer.  Provide the dealer 

with the model number, serial number, type of gas, and purchase verification.  The installing dealer is responsible for providing service and 

will contact the factory to initiate any warranted parts replacements.  Empire will make replacement parts available at the factory.  Shipping 

expenses are not covered.

 

If, after contacting your Empire dealer, service received has not been satisfactory, contact: Consumer Relations Department, 

Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois 62222, or send an e-mail to [email protected] with “Consumer Rela-

tions” in the subject line.

Your Rights Under State Law

 

This warranty gives your specific legal rights, and you may also have other rights, which vary from state to state.

EMPIRE

EMPIRE

Comfort Systems

Empire Comfort Systems Inc.

918 Freeburg Ave. Belleville, IL  62220

If you have a general question about our products, please e-mail us at 

[email protected]

If you have a service or repair question, please contact your dealer.

www.empirecomfort.com

Содержание 3588-4

Страница 1: ...tructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vici...

Страница 2: ...This series is design certified in accordance withAmerican National Standard Z21 86b 2002 by the Canadian Standards Association as a gravity type Floor Furnace and must be installed according to these...

Страница 3: ...be required due to excessive lint from carpeting bedding materials etc It is imperative thatcontrolcompartments burners andcirculating air passageways of the appliance be kept clean Do not use this h...

Страница 4: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Страница 5: ...sulated single wall metal pipe shall not be used outdoors in cold climates for venting gas utilization equipment 4 For flue pipe running through walls roof and within one 1 inch of combustible constru...

Страница 6: ...the roof through a closet re member that you MUST keep a minimum distance of 1 inch between Type B vent pipe and any combustible material See Figure 9 Run it through a single wall pipe that is 2 inche...

Страница 7: ...ion the additional furnace support and then nail the support in place by driving three nails into each end of it through the headers See Figure 10 12 Remove the jacks and supports 13 Make sure the fur...

Страница 8: ...ce between two joists because location is critical See Figure 10 If the location is not critical it is easier for you to put the furnace against a joist and then fill in with one additional support Do...

Страница 9: ...nominal pipe thread Use at least 1 2 inch pipe to avoid excessive pressure drop check lo cal codes Install the piping in accordance with the requirements described in Installation Planning Compounds...

Страница 10: ...average with the thermostat ON 140 minimum for valve to open 65 minimum for pilot to stay on Caution Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper an...

Страница 11: ...TE The gas control rod is attached to the gas control knob 4 Push in gas control rod slightly and turn clockwise to OFF Note Rod cannot be turned from PILOT to OFF un less rod is pushed in slightly Do...

Страница 12: ...ural gas models should have a manifold pressure of approximately 3 5 w c at the valve outlet with the inlet pressure to the valve from a minimum of 5 0 w c for the purpose of input of input adjustment...

Страница 13: ...ust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Страница 14: ...32186 0 0513 Page 14 20 21 22A 22B 23 24 25 EXPLODED VIEW...

Страница 15: ...15L PILOT BURNER WITH THERMOPILE LP GAS 12 602032 23218 23217 BURNER 13 732010 FF250 FF250 ELECTRODE AND WIRE 14 R2313 R2313 R2313 PIEZO IGNITOR 15 742169 P8631 P8625 BURNER ORIFICE NATURAL GAS 15 742...

Страница 16: ...ppliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this appliance Travel diagnostic costs and freight charges on warranted parts to and...

Отзывы: