WIRING INSTRUCTIoNS FoR INSTALLING A DUAL SWITCH / RECEPTACLE
In order to install both the optional Blower and Accent Light acces-
sories, it will be necessary to install the junction box so that the
Duplex Receptacle wiring is split. This will allow each side of the
receptacle to operate independently off separate wall switches.
See diagram below.
CAUTION
ALL WIRINg ShOULD BE DONE By A qUALIfIED ELECTRI-
CIAN AND ShALL BE IN COMpLIANCE WITh ALL LOCAL,
CITY AND STATE BUILDING CoDES. BEFoRE MAKING
THE ELECTRICAL CoNNECTIoN, MAKE SURE THAT MAIN
pOWER SUppLy IS DISCONNECTED. ThE AppLIANCE,
WhEN INSTALLED, MUST BE ELECTRICALLy gROUNDED
IN ACCORDANCE WITh LOCAL CODES OR, IN ThE AB-
SENCE Of LOCAL CODES, WITh ThE NATIONAL ELECTRI-
CAL CoDE ANSI/NFPA 70 (LATEST EDITIoN).
#1
ACCENT LIGHT
WALL SWITCH
#2
BLOWER
WALL
SWITCH
REMOVE TAB ON HOT SIDE
OF DUPLEX RECEPTACLE
TO SPLIT LUGS
PLUG
FOR
CONTROLS
PLUG
FOR
BLOWER
FIREPLACE
CONTROL
COMPARTMENT
DUAL SWITCH ELECTRICAL WIRING TO FIREPLACE RECEPTACLE
RED
BLACK
WHITE
3-WIRE, GROUNDED
CONDUCTOR
(BY OTHERS)
DOUBLE SWITCH BOX
(INSTALLER PROVIDED)
BLACK
WHITE
GROUND
TO 120V
CIRCUIT
BREAKER
1. To wire Junction Box Receptacle, remove the tab on the side
of the receptacle (hot side) to split receptacle. This will be
required to separate blower and Accent Light circuits.
2. Power for switched and live sides of Duplex Receptacle must
come from the same power source. (One circuit breaker on
main panel must switch all power off.)
3. From the wall box to the fireplace a 3-wire conductor with
ground is recommended, however (2) two-wire conductors
with grounds may be used in place of a 3-wire conductor with
a ground if the black wires from the Accent Light and blower
accessories are identified.
4. Two wall switches may be used to activate the two receptacle
plugs independently.
NOTICE
:
Wiring to the Junction Box should be run through the
7/8" diameter access hole located on one of the sides of the fire
-
place outer wall. A Romex type connector is provided and should
be used to protect and restrain the wiring where it passes through
the fireplace outer wall. The Junction Box should be positioned in
the lower compartment of the fireplace/firebox so that it does not
interfere with moving parts of the blower assembly. The Junction
Box incorporates magnets on the bottom side to retain and reduce
the chance of movement or vibration during blower operation.
NOTICE
:
If only the blower option is to be installed, wiring may
be performed as described and illustrated in the following Blower
Installation section.