CLEARANCES (cont.)
figure 6a - Mantel Clearances with Standard hood
figure 6b - Mantel Clearances with Optional Extended hood
MANTEL
STANDARD
HOOD
17 ½”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOP OF HOOD)
4 ½”
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREPLACE
8”
6 ½”
5”
3 ½”
1 ½”
0”
6 ½”
9”
11”
13”
15”
MANTEL
13”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOP OF HOOD)
8”
MIN.
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
22”
8”
20”
6 ½”
18”
5”
16”
3 ½”
14 ½”
2 ½”
24 ½”
0”
FIREBOX
FACE
EXTENDED HOOD
(VB4H SERIES)
(NOT AVAILABLE ON
PENINSULA OPEN END)
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREPLACE
Ceiling Clearances:
The ceiling height should not be less than 42"
from the top of the hood.
See figures 6a and 6b.
Mantel Clearances:
Vent free fireplace models must use the hood
supplied with the fireplace, or one of the optional hood kits available
for each model. If a combustible mantel is installed, it must meet
the clearance requirements detailed below.
Leave furniture and other combustible items at least 36" away from
the front openings of the fireplace.
Do not attach combustible material to the mantel of your
fireplace. This is a fire hazard.
figure 7
No greeting cards, stockings or ornamentation of any type
should be placed on or attached to the fireplace. This is a heating
appliance. The flow of heat can ignite combustibles.
figure 8
COMBUSTIBLE MATERIALS