The firebox is designed to accept a 3/8-inch gas line for an approved 

vent-free gas logset. Have the line installed by a qualified service 

person in accordance with all building codes. Consult local building 

codes to properly size the gas supply line leading to the 3/8-inch 

hook-up at the unit. The state of Massachusetts requires that a 

flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox. 

See Figure 11

When  installing  optional  ceramic  fiber  side  panels  into  firebox, 

lay panel on a flat surface. Remove the gas line knockout (round 

depression) in the appropriate side panel using a drill or utility knife.
Check gas type. Use only the gas type indicated on the gas log 

set rating plate. If the gas listed on the plate is not your type of gas 

supply, DO NOT INSTALL. Contact your dealer for proper model.
Always use an external regulator for all propane fireboxes to reduce 

the supply tank pressure to a maximum of 14 inch w.c. This is in 

addition to the regulator fitted to the log set.

WARNING:

 CONNECTION DIRECTLY TO AN UNREGULATED 

PROPANE TANK CAN CAUSE EXPLOSION. 

Install only a ANSI Z21.11.2 vent-free burner and log set into this 
firebox. 

Figure 11

Extended Hoods

If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that will 
extend out 2" farther out into the room. Contact your local dealer for details.

Finishing

All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-

combustible material. 
Hearth extensions are recommended, but not required for these  fireboxes.

VB4H32BL

Standard Black

VB4H36BL

Standard Black

VB4H42BL

Standard Black

VB4H32BR

Polished Brass

VB4H36BR

Polished Brass

VB4H42BR

Polished Brass

VB4H32SS

Stainless Steel

VB4H36SS

Stainless Steel

VB4H42SS

Stainless Steel

VB4H32HP

Hammered Pewter

VB4H36HP

Hammered Pewter

VB4H42HP

Hammered Pewter

INSTALLING HOOD (CONT'D)

GAS LINE CONNECTION

Brick Panel

Figure 12

Содержание VFP32FB Series

Страница 1: ...nstallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency...

Страница 2: ...NE CONNECTION 9 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS 10 12 OPTIONAL FBB5 SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS 13 15 JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS 16 MAINTENANCE 16...

Страница 3: ...f such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating...

Страница 4: ...Figure 1 Firebox Side and Back Clearances The firebox outer casing side and back flanges are zero clearance to combustibles Top Framing and Finishing Combustible finishing materials requires 3 4 inch...

Страница 5: ...the non combustible board supplied with the fireplace before adding paint tile or stone Attach tile or other non combustible products to the fireplace face and to the non combustible area Figures 29 a...

Страница 6: ...alled directly on carpeting tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you...

Страница 7: ...2 Height from the bottom of the box to the upper gas line opening 8 4 8 4 8 4 8 4 8 4 8 4 L Depth from the front of the box to the gas line opening 15 7 15 7 15 7 15 7 15 7 15 7 M Depth from the rear...

Страница 8: ...less steel or hammered pewter hoods are desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosely attach two screws...

Страница 9: ...ane fireboxes to reduce the supply tank pressure to a maximum of 14 inch w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED PROPANE TANK CAN C...

Страница 10: ...d prior to or at the time of firebox installation to framing The Fresh Air kit must be installed prior to the installation of wall board or other finishing materials around the unit Hardware needed no...

Страница 11: ...ilding 2 Secure the 4 inch diameter duct to the Slide Assembly collar on the firebox with band clamps or screws installer supplied 3 Run the other end of the duct through the exterior wall cutout 4 Fr...

Страница 12: ...6 1217 Page 12 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS 1 2 3 PARTS LIST INDEX NO PART NO DESCRIPTION 1 29259 Outside Air Vent Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer Hardware...

Страница 13: ...should be installed to activate power to the fireplace and control the operation of the FBB5 Blower assembly It is recommended that installa tion of the wiring be performed by a qualified electrician...

Страница 14: ...onnection A 6 The other fan control wire has a 1 4 male terminal Attach this terminal to the open terminal on the blower power cord See Figure 27 Connection B 9 Route the wires away from moving parts...

Страница 15: ...t indi cates a dirty blower wheel Remove fan and clean blower wheels Blower Wiring See Figure 26 For Wiring WARNING Unplugging of blower accessory will not stop the heater from cycling To turn off gas...

Страница 16: ...HE ELECTRICAL CONNECTION MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED THE APPLIANCE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WIT...

Страница 17: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 18: ...BLOWER COVER PLATE 5 R7051 R7052 R7053 R7051 R7052 R7053 ROD SCREEN QUANTITY 2 6 20486 21087 33607 20486 21087 33607 HOOD 7 R9292 R9292 R9292 R9292 R9292 R9292 HEARTH LEDGE RIGHT 8 R9293 R9293 R9293 R...

Страница 19: ...33742 6 1217 Page 19 PARTS VIEW LOUVER FLUSH...

Страница 20: ...V 1 Brick Liners Liner for Firebox Contact dealer for all available optional liner kits Fresh Air Kit Deluxe and Premium Fireboxes VFA2 Frame Kits 3 Piece Frame Kits Black Stainless Steel or Hammered...

Страница 21: ...hes Contact dealer for all available optional louver accessories Bottom Trim Strip Available as optional kits in Brass Hammered Pewter and Stainless Steel finishes Contact dealer for all available opt...

Страница 22: ...ctive workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated i...

Страница 23: ...33742 6 1217 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 24: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Отзывы: