Preparation

This vent free gas fireplace and its components are tested and safe 

when installed in accordance with this installation Manual. Report 

to your dealer any parts damaged in shipment, specifically check 

log  placement.  Do  not  install  unit  with  damaged,  incomplete,  or 

substitute  parts.  Read  all  instructions  before  starting  installation 

and follow these instructions carefully during installation to insure 

maximum benefit and safety. Failure to follow them will void your 

warranty and may present a fire hazard. 
The warranty will be voided by, and the warranter disclaims any 

responsibility for the following actions:
• 

Installation of any damaged fireplace.

• 

Modification of the fireplace.

• 

Installation other than as instructed by Empire Comfort Systems 

inc.

• 

Improper positioning of the logs.

• 

Installation and/or use of any component part not manufactured 

or approved by manufacturer.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or 

accessories and repair and servicing of equipment shall be performed 

only by a qualified agency. The term "qualified agency" means any 

individual, firm, corporation or company which either in person or 

through a representative is engaged in and is responsible for (a) 

the installation or replacement of gas piping or (b) the connection, 

installation, repair or servicing of equipment, who is experienced in 

such work, familiar with all precautions required and has complied 

with all the requirements of the authority having jurisdiction.

State  of  Massachusetts: 

The  installation  must  be  made 

by  a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental 

room heaters shall provide to each purchaser a copy of 527 cMR 

30 upon sale of the unit. in the state of Massachusetts, unvented 

propane or natural gas fired space heaters shall be prohibited in 

bedrooms and bathrooms.

The installation must conform with local codes or, in the absence 

of  local  codes,  with  the 

National  Fuel  Gas  Code, ANSI  Z223.1/

NFPA 54.*

*Available from the American National Standards Institute, Inc., 11 

West 42nd St., New York, N.Y. 10036.

 

WARNING

anY cHange to tHis FiRePLace oR its contRoLs can 

Be DangeRoUs.

Improper installation or use of the fireplace can cause serious 

injury or death from fire, burns, explosions, or carbon monoxide 

poisoning.
Any alteration of the original design, installed other than shown 

in these instructions or use with a type of gas not shown on 

the rating plate is the responsibility of the person and company 

making the change.
high Altitudes

For altitudes/elevations above 2,000 feet (610 m), ratings should be 

reduced at the rate of 4 percent for each 1,000 feet (305 m) above 

sea level. Contact the manufacturer or your gas company before 

changing spud/orifice size.

always consult your local Building Department regarding regulations, 

codes or ordinances which apply to the installation of an unvented 

room heater.

This appliance may be installed in an aftermarket* permanently 

located,  manufactured  (mobile)  home,  where  not  prohibited  by 

state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from 

the manufacturer.

this appliance is only for use with the type of gas indicated on the 

rating plate.

Instructions to Installer

1.  installer  must  leave  instruction  manual  with  owner  after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with unvented room heater.

3.  installer should show owner how to start and operate unvented 

room heater.

This product is design certified in accordance with American National 

Standards Institute Z21.11.2 by Underwriters Laboratories (UL)  as 

an Unvented Room Heater and should be installed according to 

these instructions.

Notice: 

Remove screw in valve cover. Screw is required to prevent 

shipping damage.

Attention: During initial use of ceramic log you will detect an 

odor as the ceramic log is cured. 
Any alteration of the original design, installed other than as 

shown  in  these  instructions  or  use  with  a  type  of  gas  not 

shown on the rating plate is the responsibility of the person 

and company making the change. Do not operate this appliance 

unless all components including logs, burners, and controls 

are in good working condition. Never operate this appliance 

if any log or twig is broken, or out of their intended position. 

Refer to Log Placement on page 11 for correct log and twig 

positioning. 
Replacement parts are available through your local dealer as 

indicated in the Parts Sections on pages 19 through 23.

 

WARNING

This appliance is equipped for (natural or propane) gas. Field 

conversion is not permitted.

 

WARNING

This unit is not for use with solid fuels.

Important

All correspondence should refer to complete Model Number, Serial 

Number and type of gas.

Notice:

 During initial firing of this unit, its paint will bake out, and 

smoke may occur. To prevent triggering of smoke alarms, ventilate 

the room in which the unit is installed.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed 

so that all burners and burner ignition devices are located not less 

than 18" (457 mm) above the floor.

Such equipment shall be located, or protected, so it is not subject 

to physical damage by a moving vehicle.

INTRODUCTION

Содержание VFP30CA30BN-3

Страница 1: ...n aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not c...

Страница 2: ...TING GUIDELINES 12 LIGHTING INSTRUCTIONS 13 PILOT FLAME CHARACTERISTICS 14 MAIN BURNER FLAME CHARACTERISTICS 15 WIRING 16 17 MAINTENANCE 17 TROUBLESHOOTING 18 19 PARTS LIST 20 PARTS VIEW 21 CASTING PA...

Страница 3: ...our shall not be installed in a bedroom or bathroom Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted...

Страница 4: ...toorintowalls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensit...

Страница 5: ...person and company making the change High Altitudes For altitudes elevations above 2 000 feet 610 m ratings should be reduced at the rate of 4 percent for each 1 000 feet 305 m above sea level Contact...

Страница 6: ...ent of the air 3 Do not use an unvented room heater as the primary heat source an entire house WATER VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Model VFP30CA30 B F M S W Input BTU HR KW H Maximum 32...

Страница 7: ...the cubic feet of the area in which the VFP30 is to be installed measure the length width and height of the area Example The area measures 17 feet in length 12 feet in width and 8 feet in height the...

Страница 8: ...edule 40 Pipe Inside Diameter Tubing Type L Outside Diameter Nat L P Nat L P 0 10 feet 0 3 meters 1 2 12 7 mm 3 8 9 5 mm 1 2 12 7 mm 3 8 9 5 mm 10 40 feet 4 12 meters 1 2 12 7 mm 1 2 12 7 mm 5 8 15 9...

Страница 9: ...proper operation must be provided Installation on Rugs and Tile This appliance must be installed on a flat solid continuous surface e g wood metal concrete This may be the floor or it may be raised up...

Страница 10: ...shutter 9 Tighten the two 2 nuts back down locking the air shutter in place Be sure that the air shutter is the same distance from the burner orifice on both sides of the air shutter for proper burner...

Страница 11: ...with toe resting on the groove in the left front log 11 Place right twig onto right side pin on rear log with toe resting all the way to the right on the right front log 12 Align and place screen fra...

Страница 12: ...ng this heater please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below 1 Know what type of ignition system this model has standing pilot...

Страница 13: ...floor If you smell gas STOP Follow B in the safety information above on this plate If you do not smell gas go to the next Step 7 Find pilot The pilot is attached to the main burner behind the front l...

Страница 14: ...cools the heater will shut down Correct Pilot Flame Pattern Figure 11 Incorrect Pilot Flame Pattern Figure 12 If pilot flame pattern is incorrect as shown in Figure 12 See Troubleshooting pages 18 and...

Страница 15: ...nt the service person should clean dust lint and any light accumulation from the logs and the firebox area An extra soft brush should be used on the logs and burner as they are extremely fragile a vac...

Страница 16: ...on remote receiver thatisacomponentintheFREC TurntheON OFF REMOTEswitch on the wire channel to the remote position Follow instructions in the FREC to complete installation NOTICE If electric 120 volt...

Страница 17: ...shown for proper main burner flame pattern Figure 14 If it appears abnormal call a service person Verify proper operation after servicing MAINTENANCE Figure 18 WIRING continued Figure 17 REMOTE OFF O...

Страница 18: ...ilot is lit a Main burner orifice clogged Clean main burner or replace main burner orifice b Main burner orifice diameter is too small Replace main burner orifice c Inlet gas pressure is too low Conta...

Страница 19: ...ile cooling This is common with most heaters If noise is excessive contact service person 12 Heater produces unwanted odor a Heaterburningvaporsfrompaint hairspray glues cleaners chemicals new carpet...

Страница 20: ...72 JAMB NUT 13 P 184 ORIFICE 35 NAT 13 P 250 ORIFICE 1 65mm LPG 14 26561 AIR SHUTTER BRACKET 15 24041 FIREBOX BOTTOM 16 15977 VALVE BRACKET 17 24024 TUBING ASSEMBLY VALVE TO BURNER 18 24246 TUBING ASS...

Страница 21: ...26563 4 0111 Page 21 PARTS VIEW 26 27 28 29 30 31 1 3 4 5 6 7 8 9 10 32 33 34 2 7 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 35...

Страница 22: ...4 R 9568 CASTING TOP 5 R 9681 CASTING FRONT 6 R 9567 CASTING SIDE RIGHT 7 R 9566 CASTING SIDE LEFT 8 R 9683 CASTING DOOR RIGHT 9 R 9682 CASTING DOOR LEFT 10 24191 FIREBOX SUPPORT BRACKET 2 REQUIRED 1...

Страница 23: ...26563 4 0111 Page 23 2 3 9 4 5 6 7 8 10 10 1 11 11 11 11 13 12 12 13 CASTING PARTS VIEW...

Страница 24: ...re to remove side shelf supports prior to removing cast iron top to eliminate potential scratching or chipping to the cast iron sides NOTICE Due to inherent properties of the casting process non combu...

Страница 25: ...tach 1 4 push on terminal from white wire on the fan control to the ON bottom tab on the switch 9 Insert AUTO OFF ON switch into rectangular notch on wire channel left Figure 23 10 Install rheostat th...

Страница 26: ...ugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for groun...

Страница 27: ...MBER DESCRIPTION 1 R 1454 BRASS BUSHING 2 R 1499 RUBBER GROMMET 3 24231 BLOWER HOUSING 4 R 1410 STRAIN RELIEF BUSHING 5 R 9927 BLOWER ASSEMBLY 6 24225 BLOWER COVER 7 R 6159 CORD SET 8 R 9699 WIRE HARN...

Страница 28: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Страница 29: ...26563 4 0111 Page 29 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 30: ...26563 4 0111 Page 30 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 31: ...ce the following minimum clearances to combustible construction must be maintained Top of appliance ceiling 36 inches Heater Corners 45 angle to Wall 4 inches Rear Wall 2 inches Floor 0 inches Side Wa...

Страница 32: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: