CAUTION

During the initial purging and subsequent lightings, never 

allow the gas valve control knob to remain depressed in the 

"pilot" position without pushing the piezo ignitor button at 

least once every second.

2.  During the heating season, leave the control valve knob in the 

"ON" position. This will allow the pilot flame to remain lit. Turn 

the burner flame on or off with the appliance REMOTE/OFF/ON 

rocker switch, wall switch, remote control kits or 750 millivolt wall 

thermostat.

NOTICE

:

 the gas control valve allows you to increase or decrease 

the height of the main burner flame. The control valve has a pressure 

regulator  with  a  knob  as  shown  in  Figure  10  .  Rotate  the  knob 

clockwise to "HI" to increase the flame height and counterclockwise 

to "LO" to decrease the flame height.
3.  When the heating season is over, turn the REMOTE/OFF/ON 

switch to "oFF" and the control valve to "oFF". the system, 

including the pilot light, will be shut down.

Maximum and Minimum Input

The gas valve on the appliance allows the input to adjust between 

a maximum input of 32,000 Btuh to a minimum input of 22,400 

Btuh. Please be advised, the maximum input provides the greatest 

amount of yellow flame and ember glow on the log set. The minimum 

input substantially decreases the yellow flame and ember glow on 

the log set.

Before  operating  this  heater,  please  review  the  safety  warnings 

pages at the beginning of this manual and those precautions and 

warnings listed below.

1.  Know  what  type  of  ignition  system  this  model  has  (standing 

pilot)  and  follow  the  applicable  SAFETY  and  LIGHTING 

instructions.

2.  Check  to  ensure  there  are  no  gas  leaks.  If  you  are  unsure, 

turn gas off to the heater and call a service person or your gas 

utility.

 

CAUTION

Clothing or other flammable material should not be placed 

on or near the appliance.

 

WARNING

Children  and  adults  should  be  alerted  to  the  hazard  of 

high  surface  temperature  and  should  stay  away  to  avoid 

burns  or  clothing  ignition.  young  children  should  be 

carefully supervised when they are in the same room as the 

appliance.

3.  tampering  is  DangeRoUs  and  voids  all  warranties.  any 

component that is found to be faulty, must be replaced with an 

approved component.

Initial Lighting (Figure 10)

Upon completing the gas line or turning the gas valve "on" after it 

has been in the "OFF" position, a small amount of air will be in the 

lines. When first lighting the appliance, it will take a few minutes 

for the lines to purge themselves of this air. once the purging is 

complete, the appliance will light and operate satisfactorily.

Subsequent lightings of the appliance will not require such purging 

if the gas valve is not turned to "oFF."

Standing Pilot Operation

1.  Follow the saFetY and LigHting instRUctions for standing 

pilot controls found in this manual and on labels found attached 

to the appliance.

Figure 10

OPERATING GUIDELINES

Содержание VFP30CA30BN-3

Страница 1: ...n aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not c...

Страница 2: ...TING GUIDELINES 12 LIGHTING INSTRUCTIONS 13 PILOT FLAME CHARACTERISTICS 14 MAIN BURNER FLAME CHARACTERISTICS 15 WIRING 16 17 MAINTENANCE 17 TROUBLESHOOTING 18 19 PARTS LIST 20 PARTS VIEW 21 CASTING PA...

Страница 3: ...our shall not be installed in a bedroom or bathroom Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted...

Страница 4: ...toorintowalls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensit...

Страница 5: ...person and company making the change High Altitudes For altitudes elevations above 2 000 feet 610 m ratings should be reduced at the rate of 4 percent for each 1 000 feet 305 m above sea level Contact...

Страница 6: ...ent of the air 3 Do not use an unvented room heater as the primary heat source an entire house WATER VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Model VFP30CA30 B F M S W Input BTU HR KW H Maximum 32...

Страница 7: ...the cubic feet of the area in which the VFP30 is to be installed measure the length width and height of the area Example The area measures 17 feet in length 12 feet in width and 8 feet in height the...

Страница 8: ...edule 40 Pipe Inside Diameter Tubing Type L Outside Diameter Nat L P Nat L P 0 10 feet 0 3 meters 1 2 12 7 mm 3 8 9 5 mm 1 2 12 7 mm 3 8 9 5 mm 10 40 feet 4 12 meters 1 2 12 7 mm 1 2 12 7 mm 5 8 15 9...

Страница 9: ...proper operation must be provided Installation on Rugs and Tile This appliance must be installed on a flat solid continuous surface e g wood metal concrete This may be the floor or it may be raised up...

Страница 10: ...shutter 9 Tighten the two 2 nuts back down locking the air shutter in place Be sure that the air shutter is the same distance from the burner orifice on both sides of the air shutter for proper burner...

Страница 11: ...with toe resting on the groove in the left front log 11 Place right twig onto right side pin on rear log with toe resting all the way to the right on the right front log 12 Align and place screen fra...

Страница 12: ...ng this heater please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below 1 Know what type of ignition system this model has standing pilot...

Страница 13: ...floor If you smell gas STOP Follow B in the safety information above on this plate If you do not smell gas go to the next Step 7 Find pilot The pilot is attached to the main burner behind the front l...

Страница 14: ...cools the heater will shut down Correct Pilot Flame Pattern Figure 11 Incorrect Pilot Flame Pattern Figure 12 If pilot flame pattern is incorrect as shown in Figure 12 See Troubleshooting pages 18 and...

Страница 15: ...nt the service person should clean dust lint and any light accumulation from the logs and the firebox area An extra soft brush should be used on the logs and burner as they are extremely fragile a vac...

Страница 16: ...on remote receiver thatisacomponentintheFREC TurntheON OFF REMOTEswitch on the wire channel to the remote position Follow instructions in the FREC to complete installation NOTICE If electric 120 volt...

Страница 17: ...shown for proper main burner flame pattern Figure 14 If it appears abnormal call a service person Verify proper operation after servicing MAINTENANCE Figure 18 WIRING continued Figure 17 REMOTE OFF O...

Страница 18: ...ilot is lit a Main burner orifice clogged Clean main burner or replace main burner orifice b Main burner orifice diameter is too small Replace main burner orifice c Inlet gas pressure is too low Conta...

Страница 19: ...ile cooling This is common with most heaters If noise is excessive contact service person 12 Heater produces unwanted odor a Heaterburningvaporsfrompaint hairspray glues cleaners chemicals new carpet...

Страница 20: ...72 JAMB NUT 13 P 184 ORIFICE 35 NAT 13 P 250 ORIFICE 1 65mm LPG 14 26561 AIR SHUTTER BRACKET 15 24041 FIREBOX BOTTOM 16 15977 VALVE BRACKET 17 24024 TUBING ASSEMBLY VALVE TO BURNER 18 24246 TUBING ASS...

Страница 21: ...26563 4 0111 Page 21 PARTS VIEW 26 27 28 29 30 31 1 3 4 5 6 7 8 9 10 32 33 34 2 7 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 35...

Страница 22: ...4 R 9568 CASTING TOP 5 R 9681 CASTING FRONT 6 R 9567 CASTING SIDE RIGHT 7 R 9566 CASTING SIDE LEFT 8 R 9683 CASTING DOOR RIGHT 9 R 9682 CASTING DOOR LEFT 10 24191 FIREBOX SUPPORT BRACKET 2 REQUIRED 1...

Страница 23: ...26563 4 0111 Page 23 2 3 9 4 5 6 7 8 10 10 1 11 11 11 11 13 12 12 13 CASTING PARTS VIEW...

Страница 24: ...re to remove side shelf supports prior to removing cast iron top to eliminate potential scratching or chipping to the cast iron sides NOTICE Due to inherent properties of the casting process non combu...

Страница 25: ...tach 1 4 push on terminal from white wire on the fan control to the ON bottom tab on the switch 9 Insert AUTO OFF ON switch into rectangular notch on wire channel left Figure 23 10 Install rheostat th...

Страница 26: ...ugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for groun...

Страница 27: ...MBER DESCRIPTION 1 R 1454 BRASS BUSHING 2 R 1499 RUBBER GROMMET 3 24231 BLOWER HOUSING 4 R 1410 STRAIN RELIEF BUSHING 5 R 9927 BLOWER ASSEMBLY 6 24225 BLOWER COVER 7 R 6159 CORD SET 8 R 9699 WIRE HARN...

Страница 28: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Страница 29: ...26563 4 0111 Page 29 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 30: ...26563 4 0111 Page 30 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 31: ...ce the following minimum clearances to combustible construction must be maintained Top of appliance ceiling 36 inches Heater Corners 45 angle to Wall 4 inches Rear Wall 2 inches Floor 0 inches Side Wa...

Страница 32: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: