Clearances (Figures 2, 3, and 4)
When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Top of appliance (ceiling)
36 inches
Rear Wall
2 inches
Side Wall
6 inches
Heater Corners (45° angle) to Wall
4 inches
Floor
0 inches
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
Installation on Rugs and Tile
This appliance must be installed on a flat, solid, continuous surface
(e.g. wood, metal, concrete). This may be the floor, or it may be
raised up on a platform to enhance its visual impact. The appli
-
ance may be installed on carpeting, vinyl, wood flooring or other
combustible material.
CLEARANCES
Figure 2
Figure 3
Figure 4
6” (153mm) TO SIDE WALL
OR COMBUSTIBLE
MATERIAL
36” (91cm) TO CEILING OR
HORIZONTAL PROJECTION
ABOVE APPLIANCE
NOTE: HEATER INSTALLED AT
45° ANGLE IN CORNER
4” (102mm) HEATER CORNERS
TO SIDE WALL
4”
(102mm)
2” (51mm) TO COMBUSTIBLE MATERIAL