background image

23466-4-0509

Page 2

SECTION 

pAGE

IMPORTANT SAFETY INFORMATION ..................................................................................... 3
SAFETY INFORMATION FOR USERS OF LP-GAS ................................................................. 4
INTRODUCTION .......................................................................................................................... 5
BUILT-IN FIREPLACE INSTALLATION .................................................................................... 6
FIREPLACE DIMENSIONS ......................................................................................................... 7
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS .................................. 8
SPECIFICATIONS ......................................................................................................................... 8
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR ..........................9-10
GAS SUPPLY ............................................................................................................................... 11
CLEARANCES ............................................................................................................................ 12
COMBUSTIBLE MATERIAL ..................................................................................................... 12
INSTALLATION OF FIREPLACE AND MANTEL .............................................................13-14
LOG PLACEMENT ..................................................................................................................... 15
PLACEMENT OF GLOWING EMBERS (ROCK WOOL) ....................................................... 16
OPERATION INSTRUCTIONS/FLAME APPEARANCE ........................................................ 16
(A)VFD26FP3L10 LIGHTING INSTRUCTIONS ...................................................................... 17
(A)VFD26F(M,P)3 LIGHTING INSTRUCTIONS ..................................................................... 18
(A)VFD26F(M,P)2 LIGHTING INSTRUCTIONS ..................................................................... 19
PILOT FLAME CHARACTERISTICS ..................................................................................20-21
MAIN BURNER AND THERMOSTAT OPERATION .............................................................. 21
OUTER TRIM INSTRUCTIONS ................................................................................................ 22
HOOD INSTRUCTIONS ............................................................................................................. 22
(A)VFD26F3 WIRING ................................................................................................................ 23
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS .............................................. 24
TROUBLESHOOTING ............................................................................................................... 25
PARTS LIST ................................................................................................................................. 26
PARTS VIEW ............................................................................................................................... 27
FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS ..........................28-29
FBB4 OPTIONAL VARIABLE SPEED BLOWER .................................................................... 29
FPP26E OPTIONAL BRICK LINER KIT INSTALLATION INSTRUCTIONS ....................... 30
HOW TO ORDER REPAIR PARTS ............................................................................................ 31
SERVICE NOTES ........................................................................................................................ 31

TABLE OF CONTENTS

Содержание VFD26FM series

Страница 1: ...per hour Refer to page 8 WARNING If not installed operated and main tained in accordance with the manufacturer s in structions this product could expose you to sub stances in fuel or from fuel combus...

Страница 2: ...ERS ROCK WOOL 16 OPERATION INSTRUCTIONS FLAME APPEARANCE 16 A VFD26FP3L10 LIGHTING INSTRUCTIONS 17 A VFD26F M P 3 LIGHTING INSTRUCTIONS 18 A VFD26F M P 2 LIGHTING INSTRUCTIONS 19 PILOT FLAME CHARACTER...

Страница 3: ...e hazard of high surface temperature and should stay away to avoid burns or clothing ignition Young childrenshould becarefullysupervisedwhen they are in the same room with the appliance Do not place c...

Страница 4: ...ight pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or...

Страница 5: ...gas company before changing spud orifice size Warning Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage Instructions to Installer 1 Installer m...

Страница 6: ...own in Figure 2 for corner rough opening Be sure to provide gas line for fireplace and electrical power for optional blower assembly 1 Attach two 2 nailing flanges to firebox sides with two 2 10 x 1 2...

Страница 7: ...E OPENING JUNCTION BOX ASSEMBLY GAS LINE OPENING J I K B C G A D E Figure 4 A VFD26 Series Dimensions Index Letter Dimension A 30 1 4 768mm B 30 762mm C 13 1 8 333mm D 18 1 8 460mm E 26 660mm G 25 635...

Страница 8: ...rmostat FREC Electric Remote Control FWS 1 Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Wireless Remote Wall Thermostat Water vapor is a by product of gas combustion An unvented room heat...

Страница 9: ...e volume is less than 50 cubic feet per 1 000 Btu per hour 4 8m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not l...

Страница 10: ...e extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one with 12 of the floor Connect these items directly to the outdoorsors...

Страница 11: ...tors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector c...

Страница 12: ...rances from the top of the fireplace opening to the ceiling should not be less than 36 inches Mantel Clearances for Built in Installation Figure 9 Do not attach combustible material to the mantel of y...

Страница 13: ...Remove shrink wrap and logs from fireplace 6 Place back base and fireplace in desired location 7 Connect gas line and electrical wiring at this time in accor dance with local codes 8 Place mantel ass...

Страница 14: ...ogs per the Log Placement Instructions See Page 15 14 Install hood See Page 22 9 Attach mantel assembly to studs in the wall through the back brace using two 2 3 drywall screws provided 10 Slide front...

Страница 15: ...This step is optional for A VFD26FP3L10 log sets Place front twig 5 onto 1 log and flat area on 3 log The bottom of the front twig is to be placed behind the grate tang that is second from the left At...

Страница 16: ...burner as well as the main flame should be visually checked as the log set is installed In normal operation at full rate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOT...

Страница 17: ...r assembly if applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot b...

Страница 18: ...able 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT...

Страница 19: ...liance 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable Lighting Instructions 7 Turn gas control knob counterc...

Страница 20: ...Troubleshooting page 25 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by...

Страница 21: ...FF is the OFF position PILOT is the PILOT position A VFD26F M P 3 Max 20 000 BTU HR Min 14 000 BTU HR A VFD26FP3L10 Max 10 000 Min N A A VFD26F M P 2 Main Burner Operation The gas control modulates fr...

Страница 22: ...fireplace Attach top frame to fireplace Use two 2 8 x 1 2 Phillips screws for top frame 5 Replace bottom louver 6 Replace top louver 3 PIECE FRAME KIT SIDE TRIM Figure 21 HOOD INSTRUCTIONS 1 Remove up...

Страница 23: ...burner assembly Note Do not let remote control receiver come in contact with burner assembly On circulating vent free firebox install remote control receiver behind bottom louver Refer to remote contr...

Страница 24: ...ELECTRICAL CODE ANSI NFPA 70 LATEST EDITION A factory installed junction box is located on the lower right side of the fireplace Wiring must be fed to the junction box and attached to the receptacle t...

Страница 25: ...ct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough...

Страница 26: ...N S R3435 WIRE ASSEMBLY A VFD26F M P 3LP PART NUMBERS 10 R3623 PILOT ASSEMBLY 11 21590 PILOT BRACKET 14 R9022 BURNER TUBE 16 P182 ORIFICE 19 23493 TUBING ASSEMBLY 21 R3625 VALVE 23 23496 TUBING ASSEM...

Страница 27: ...e 27 PARTS VIEW 5 PIECE LOG Y ASSEMBL MILLIVOLT VALVE Y ASSEMBL THERMOSTATIC VALVE Y ASSEMBL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 21 22 23 23 24 25 26 27 28 29 29 30 31 18 32 33...

Страница 28: ...of fireplace The magnets on the bottom of speed control will sufficiently hold the speed control in place 13 Attach fan control bracket to upper right side of firebox with one 10 x 1 2 hex screw prov...

Страница 29: ...r Kit 110 VOLT AC JUNCTION BOX WHITE SPEED CONTROL FAN SWITCH GROUND BLACK FAN WHITE BLACK SWITCH BRACKET FBBX Wiring Diagram FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS cont FBB4 OPTIONAL VAR...

Страница 30: ...e 1 side panel into firebox 5 Align clearance hole on brick panel bracket with screw hole in the left or right interior top of firebox Use two 2 10 x 1 2 screws to attach brick panel bracket to interi...

Страница 31: ...ne the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fir...

Страница 32: ...23466 4 0509 Page 32 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62222 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Отзывы: