Countdown Timer

The Countdown Timer Mode allows the control to operate the unit 

for up to 3 hours, in 10-minute increments.  It can be operated in 

either the Manual or Thermostat Modes.

1.  To enter Timer Mode, press and release the TIMER button.  

The Timer icon will flash.

2.  Press  the  UP  or  DOWN  button  to  set  the  running  time,  in 

10-minute increments.  Press and release the SET button.  

The timer will run for the set time duration.

3.  Pressing the TIMER button while in Timer Mode will terminate 

the Timer operation.  The Timer operation will also terminate if 

the MODE button is cycled to off.

Thermostat Mode

The unit is placed in Thermostat Mode using the MODE button.  

Placing the unit in Thermostat Mode will activate the numbers in 

the smaller window on the LCD screen.

1.  Press the UP or DOWN button to change the thermostat set 

temperature.    When  the  desired  set  temperature  appears, 

press and release the SET button to set.  

2.  If the SET button is not pressed, the set temperature will au

-

tomatically be set after 5 seconds.

3.  The Thermostat  Mode  can  be  de-activated  by  pressing  the 

MODE button.

Thermostatic Flame Modulation

This control can perform Main Flame Modulation using the Ther-

mostat.  The control will shut the unit off when the room tempera

-

ture reaches 2° above set temperature.  The Thermostat will auto

-

matically modulate the main flame as follows:

 

2° above set temperature   

OFF

 

1° above set temperature   

Flame Level 1

 

    at set temperature 

 

Flame Level 2

 

1° below set temperature   

Flame Level 3

 

2° below set temperature   

Flame Level 4

 

3° below set temperature   

Flame Level 5

 

4° below set temperature   

Flame Level 6

 

5° below set temperature   

Flame Level 7

Manual Flame Modulation – Main Flame

To  change  the  Flame  Level  manually,  press  the  FLAME  MAIN 

button.  The current level will show in the MAIN box on the LCD 

screen.

1.  Press the UP or DOWN button to change the Flame Level.

2.  When the unit is turned on, whether in Manual, Thermostatic, 

or Program Mode, the Main Flame will automatically ignite at 

the High (7) setting.  After 5 seconds, the flame will default to 

the previous setting.

Manual Flame Modulation - Rear Flame

Feature not available. 

Fan Control

The unit must be ON to operate the Fan.

The Fan will turn on after 5 minutes of operation.  Once the Fan 

comes on, it can be controlled using the FAN button.  

1.  Press the FAN button, and the fan icon and speed will appear 

on the LCD screen.

2.  Press the UP or DOWN button to control the fan speed.  Press 

the DOWN button until 0 Level is reached to turn the Fan off.

3.  The fan will run for 12 minutes after the unit is shut off in any 

mode.  The fan may not be controlled during this period.

Accent Light

Not available on all models

The unit does NOT have to be on to operate the lights.  

Lights are controlled by the LIGHTS button on the transmitter.

1.  Press the LIGHTS button and the light icon and intensity level 

will appear on the LCD screen.

2.  Press the UP or DOWN button to set the light intensity level.  

Press SET, or wait 7 seconds, and the light intensity setting 

will be established.

Continuous Pilot

The unit can be changed from Intermittent Pilot Ignition (IPI), to 

Continuous, or standing, pilot.

1.  To place the unit in continuous pilot mode, press and release 

the PROG/TIME and the FLAME MAIN buttons simultane-

ously

.  Continuous Pilot will appear on the LCD screen.

2.  Repeat the simultaneous PROG/TIME and FLAME MAIN 

push to place the unit back in IPI mode.

3.  This  feature  can  also  be  activated  by  the  Continuous  Pilot 

(On/Off) switch on the Main Module.