Empire Comfort Systems R11006 Скачать руководство пользователя страница 2

28641-1-0512

Page 2

Initial Remote Setup

Installation of (2) AAA-size batteries will activate the setup mode.   

Setup mode can also be activated by pressing the FLAME REAR 

and PROG/TIME buttons simultaneously for 5 seconds.  The con-

trol will exit setup mode if no button is pressed for 20 seconds.  

Appropriate icon on LCD will flash when ready for setup.

1.  Press the UP or Down button in setup mode to change the 

temperature scale.  Press SET button to skip or advance to 

Fuel Type setup.

2.  To switch between the NG and LP step motor settings, press 

and hold the learn button for 20 seconds. The module should 

emit a short beep (less than 1 second) to indicate that the 

control was switched from NG (default setting) to LP. When 

switching back from LP to NG, the control should emit a long 

beep (3 seconds).

Note: 

When installing or replacing batteries, the Remote Control 

handset should be reset to the appropriate NG or LP icon 

depending on the appliance gas type specified on the rating 

plate.

3.  Press the UP or Down Button to set the hour.  Press SET to 

advance to minutes.

4.  Press the UP or Down button to set minutes.  Press SET to 

advance to AM or PM.

5.  Press the UP or Down button to set AM or PM.  Press the SET 

button to advance to the day of week.

6.  Use UP or Down button to select the day of the week.  

7.  The control will exit setup mode in 20 seconds.

Learn Function

1.  To program the system to a transmitter, press the LEARN but

-

ton on the Main Module. A single audible beep will be heard.

2.  Press the MODE button on the transmitter to learn the trans-

mitter to the system.  A series of beeps will be heard.

3.  Up  to  two  additional  (NON-THERMOSTATIC)  transmitters 

can be used simultaneously.  To learn additional transmitters, 

press and release the learn button again, and press the on 

button on the additional transmitters.

4.  To  clear  all  transmitters  and  start  over,  press  and  hold  the 

LEARN button for 10 seconds.  A series of three beeps will be 

heard, and the system is clear.

Child Lock-Out

The  Child  Lock-out  feature  can  be  activated  by  pressing  the 

PROG/Time and UP buttons simultaneously 

for five seconds.  CP 

will appear on the LCD in the ROOM box on the screen, and no 

signals can be sent from the transmitter.

To take the control out of Child Lock-out mode, repeat the above 

step.  CP will disappear from the screen.

Thermal Safety

When the internal components of the Main Module reach 170°F, 

the unit will automatically shut off, and send a repetitive audible 

signal.  The unit can be turned back on when the module cools 

below 160°

Communication Safety

When  in  the  Thermostat  or  Program  Mode,  the  transmitter  will 

send a silent signal to the module every 15 minutes.  If a signal is 

not received within 2 hours due to dead batteries, lost transmitter, 

or transmitter out of range, the unit will automatically shut down, 

and the module will send a repetitive audible signal.

Low Battery Indicator

A  low  battery  icon  will  appear  on  LCD  screen  when  transmitter 

batteries reach low voltage level. When the batteries are replaced, 

Initial  Remote  Setup,  Learn  Function  and  any  programing  will 

need to be redone.

MODE Button

The MODE button cycles the unit through the basic operational 

modes.

1.  When off, press and release the MODE button to turn the unit 

on in Manual mode.

2.  Press and release the MODE button again, and the unit will 

operate in the Thermostat mode.

3.  Press and release the MODE button again, and the unit will 

turn off.

Program Mode

The Program function is controlled by the PROG/TIME button.  

The control may be programmed for up to two settings for week

-

days and two settings for weekends.  The control is preset to fac

-

tory settings.

When the Program Mode is activated, the unit will automatically 

be operating in the Thermostat Mode.  The unit will turn on or off 

based upon room and set temperature.

To activate the Program mode, press and release the PROG/TIME 

button.

1.  To change the settings for the Program mode, press and hold 

the PROG/TIME button for 5 seconds.  The program feature 

will flash at the top of the screen.

For Weekday Settings

2.  Press the UP or DOWN button to change the setting of the 

weekday  (Mon,Tues,Wed,Thurs,Fri)  P1  ON.    Press  and  re

-

lease the SET button.

3.  Press the UP or DOWN button to change the setting of P1 

OFF. Press and release the SET button.

4.  Press the UP or DOWN button to change the setting of P2 

ON.  Press and release the SET button.

5.  Press the UP or DOWN button to change the setting of P2 

OFF. Press and release the SET button.

For Weekend Settings

6.  Press the UP or DOWN button to change the setting of the 

weekend (Sat, Sun) P1 ON.  Press and release the SET but

-

ton.

7.  Press the UP or DOWN button to change the setting of P1 

OFF. Press and release the SET button.

8.  Press the UP or DOWN button to change the setting of P2 

ON.  Press and release the SET button.

9.  Press the UP or DOWN button to change the setting of P2 

OFF. Press and release the SET button.

10.  The Program Mode has been re-programmed.