Mantel Chart (Figure 4)
Figure 3
Clearances (Figure 5)
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
Figure 5
15”
(381mm)
TOP EDGE OF FIREPLACE
12” (305mm)
10” (254mm)
MANTEL
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
3” MIN.
4”
5”
6”
7”
8”
9”
11”
13 3/4”
3/4”
1 ½”
2 1/4”
3”
3 3/4”
4 ½”
6”
8”
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
NON-COMBUSTIBLE
FIRST 3 (SEE MAGNIFIED
VIEW)
NAILING
FLANGES
GLASS FRONT
TOP FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
3"
”
CLEARANCES
(914mm)
FRONT FACE (SIDE)
FIREPLACE
(TOP VIEW)
3
MAX.
PERPENDICULAR
SIDE WALL
45°
6
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
Figure 3