28649-2-0811
Page 15
INSTALLATION (continued)
HORIZONTAL ONLY, STRAIGHT OUT THE BACK
"A"
"B"
MODEL
6"(152mm) 5 1/8"(130mm) to 6 /2"(165mm)
DVP 42,48
9"(229mm) 8 1/8"(206mm) to 91/2"(241mm)
DVP 42
12"(305mm) 11 1/8"(283mm) to 12 1/2"
(317mm)
DVP 42
Figure 17
VERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
"A"
"B"
"C"
6"(152mm)
11 1/4"(286mm) to
12 3/4"(324mm)
4 3/4"(121mm) to
6 1/4"(159mm)
9"(229mm)
14 1/4"(362mm) to
15 3/4"(400mm)
7 3/4"(197mm) to
9 1/4"(235MM)
12"(305mm)
17 1/4"(438mm) to
18 3/4"(476mm)
10 3/4"(273mm) to
12 1/4"(311mm)
VENT CAP
A"
PIPE LENGTH
WALL FIRESTOP/
THIMBLE
"
WALL FIRESTOP/
THIMBLE
Figure 18
CORNER INSTALLATION VERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
VENT
CAP
WALL FIRESTOP/
THIMBLE
Dim.
DVP42
DVP48
A
45 3/8"
1152mm
49 5/8"
1260mm
B
32 1/8"
816mm
35 1/8"
892mm
C
13 3/8"
34 mm
15 1/2"
39 mm
D
64 1/8"
1628mm
70 1/8"
1781mm
Figure 19
CORNER INSTALLATION HORIZONTAL, 45° ELBOW TO
HORIZONTAL OUT THE WALL
WALL FIRESTOP/
THIMBLE
DVP42
DVP48
"A"
"B"
"B"
6"(152mm) 4"(102mm) to
5 1/2"(140mm)
4"(102mm) to
5"(127mm)
9"(229mm) 6"(152mm) to
7 /2"(191mm)
6"(152mm) to
7 1/2"(191mm)
12"(305mm) 9"(229mm) to
10 1/2"(267mm)
9"(229mm) to
10 1/2"(267mm)
Figure 20