INTRODUCTION

at 1/8 in to 1/4 in per foot. Metal safety strips must be on top of 

any combustible hearth materials used for moisture management.

When purchasing a firebox or fireplace we recommend you also 

buy a weather cover or glass door accessory to protect the unit 

from moisture. Never install a burner where moisture cannot drain 

off easily. We recommend a weather barrier - such as a cover or 

bifold glass doors - to protect the burner from moisture.

Screened porch Installation

The  fireplace  may  be  installed  safely  and  is  design  certified  by 

CSA to be installed in a screen porch with the following guidelines.

Minimum Porch Area 

96 sq. feet (9 sq m)

Minimum Ceiling Height 

92" (234 cm)

Minimum of two (2) walls must be screened

Minimum top of screen height, side walls 

6'6" (198 cm)

Minimum screen area 

64 sq. feet (6 sq m)

Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other 

combustible material other than wood flooring the appliance shall 

be installed on a metal or wood panel extending the full width and 

depth of the appliance.  

The base referred to above does not mean the fire-proof base as 

used on wood stoves.  The protection is for rugs that are extremely 

thick and light colored tile.

Solid-fuels shall not be burned in a masonry or 

UL 127

 factory-

built fireplace in which an unvented room heater is installed.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment  

or  accessories  and  repair  and  servicing  of  equipment  shall  be 

performed only by a  qualified agency.  The term "qualified agency" 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible for 

(a) the installation or replacement of gas piping or (b) the connection, 

installation, repair or servicing of equipment, who is experienced in 

such work, familiar with all precautions required and has complied 

with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by 

a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts.

The installation must conform with local codes or, in the absence 

of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc.  1430 

Broadway, New York, N.Y. 10018.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be 

reduced at the rate of 4 percent for each 1,000 feet (305m) above 

sea level. Contact the manufacturer or your gas company before 

changing spud/orifice size.

Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect the 

Btu output of the unit. Contact the gas company for the heating value. 

Contact the manufacturer or your gas company before changing 

spud/orifice size.

WARNING:

 This appliance is equipped for (natural gas or propane) 

gas. Field conversion is not permitted.

Instructions to Installer

1. Installer must leave instruction manual with owner after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with this fireplace.

3.  Installer should show owner how to start and operate unvented 

room heater.

Always consult your local Building Department  regarding regulations, 

codes or ordinances which apply to the installation of an unvented 

room heater.
*Aftermarket:  Completion of sale, not for purpose of resale, from 

the manufacturer.

This appliance is only for use with the type of gas indicated on the 

rating plate.  This appliance is not convertible for use with other gases.

 

WARNING

ANY CHANGE TO THIS APPLIANCE OR ITS CONTROLS CAN 

BE DANGEROUS. 

Improper installation or use of the appliance can cause se-

rious injury or death from fire, burns, explosion or carbon 

monoxide poisoning.

This series is design certified in accordance with American National 

Standard Z21.97.1/CSA 2.41 by the Canadian Standards Association 

Laboratories as an Outdoor Gas Fireplace and should be installed 

according to these instructions.

Any alteration of the original design, installed other than as 

shown in these instructions or use with a type of gas not 

shown on the rating plate is the responsibility of the person 

and company making the change.
750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts 

(electrical current) which energizes the magnet in the gas valve. 

After 30 seconds to 1 minute time period you can release the gas 

control knob and the pilot will stay ON. Allow your pilot flame to 

operate an additional one (1) to two (2) minutes before you turn the 

gas control knob from the PILOT position to the ON position. This 

time period allows the millivolts (electrical energy) to build-up to a 

sufficient level allowing the gas control to operate properly. 

Important

All correspondence should refer to complete Model Number, Serial 

Number and type of gas.

Moisture Resistance

This outdoor fireplace will shed moderate amounts of water, but is 

not waterproof. Water and condensing water vapor may enter the 

chase under certain conditions.

The fireplace will not perform as an exterior wall. Moisture penetration 

must  be  considered  for  construction  that  places  the  fireplace  in 

structure walls or on moisture sensitive surfaces.

When installed on exterior walls: Empire Comfort Systems 

recommends  the  fireplace  chase  be  constructed  outside  the 

structure's weather envelope. Where the platform meets the wall, use 

a flashing detail similar to that required for attached decks. Chase 

platforms, including hearths should slope away from the structure 

at 1/4 in per foot. The fireplace can be shimmed level.

When installed on surfaces where water may collect or cause 

damage: Empire Comfort Systems recommends a slope of 1/8 in 

to 1/4 in per foot towards the drain port suggested. The fireplace 

can be shimmed level.

Hearths should slope away from the front of the fireplace and chase 

Содержание OLP36FP72S-1

Страница 1: ...formation in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration ser...

Страница 2: ...s 9 Planning Installation 10 Fireplace Framing and Installation 11 Operation Instructions Flame Appearance 12 OLP 36 42 FP72 Lighting Instructions 13 Pilot and Main Burner Flame Characteristics 14 Wir...

Страница 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION Do Not Operate...

Страница 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Страница 5: ...NING Thisapplianceisequippedfor naturalgasorpropane gas Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer...

Страница 6: ...the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equall...

Страница 7: ...ock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Compounds used...

Страница 8: ...supplied with the fireplace If a combustible mantel is installed it must meet the clearance requirements detailed above COMBUSTIBLES ALLOWED MANTEL HOOD 2 18 3 4 4 21 1 2 16 6 24 1 4 8 27 27 3 4 10 12...

Страница 9: ...S REFERENCE LETTER OLP36FP OLP42FP A 37 5 8 37 5 8 B 39 1 2 43 1 2 C 19 13 16 19 13 16 D 33 37 E 35 35 F 36 40 G 24 3 8 24 3 8 H 6 1 8 6 1 8 I 30 9 16 30 9 16 J 8 3 8 8 3 8 K 4 3 4 4 3 4 L 36 3 16 38...

Страница 10: ...ude covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 82 inches Minimum of two walls to be open or screened to the following gu...

Страница 11: ...MING REQUIRED COMBUSTIBLE MATERIAL NOT ALLOWED ADJACENT TO FIREPLACE NOTE FINISH MUST BE CONCRETE BOARD OR NON COMBUSTIBLE MATERIAL OLP36FP OLP42FP A 38 1 2 38 1 2 B 40 44 C 19 3 8 19 3 8 Attention Ad...

Страница 12: ...ors remaining after this initial break in will be slight and will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid...

Страница 13: ...e appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise...

Страница 14: ...mproper and dangerous operation Verify proper operation after servicing 1 Remove batteries 4 and battery pack from instruction envelope package 2 Slide battery cover plate off of battery pack insert b...

Страница 15: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Страница 16: ...ontrol knob to LOW position and let warm up for a minute b Air in gas line Operate burner until air is removed from line Have gas line checked by local gas company c Dirty or partially clogged burner...

Страница 17: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Страница 18: ...572 R7572 Jamb Nut 16 R10808 R10808 Air Shutter 17 R2423 R2423 Connector Male 5 16 X 3 8 NPT 18 28089 28089 Valve Shield 19 P253 P253 Orifice Fitting 20 P301 P209 Orifice Nat 20 P245 P265 Orifice LP 2...

Страница 19: ...27825 7 1212 Page 19 PARTS VIEW 13 13 14 3 3 1 1 4 6 5 2 16 20 19 22 18 24 31 28 35 12 29 33 15 21 25 17 36...

Страница 20: ...must be installed by a qualified installer and operated in accordance with the written instructions furnished with the appliance Ready access to the appliance for service is the responsibility of the...

Отзывы: