ACCENT LAMP
Your Luxury Direct Vent Gas Fireplace comes equipped with our
"Accent Lamp." The light has been pre-wired and is controlled from
the Rheostat.
If in the event the lamp or lens needs to be replaced, follow the
instructions below:
1. Unplug the Accent Lamp from the junction box inside the
fireplace.
2. Remove the four screws that secure the lens frame. This frame
retains the glass lens. The bulb can now be accessed.
NOTE:
Do not handle the lamp (bulb) with bare fingers, protect
with clean dry cloth.
The lamp will pull straight out of the socket.
When re-installing, ensure integrity of gasket seal.
THE FIREBOX MUST BE SEALED.
Over-tightening the screws could break the lens.
"Light Leakage" from the upper area may be observed. The holes
in the lamp housing are necessary for ventilation and must not be
covered.
REPLACEMENT BULBS
Replacement bulbs are available locally at most hardware, appliance
or building supply stores. Replace with a G9 (120V/25W) series
halogen bulb.