39357-0-1018
Page 29
DvvK-4Fv DIRECT vENT TERMINATION KIT
INSTALLATION INSTRUCTIONS
This termination kit can only be used with Empire Comfort Sys-
tems direct vent fireplaces listed for use with DVVK-4FV Vertical
Flex Vent kit. Please review the instructions packaged with your
fireplace and verify the fireplace model number. Check that this
flex vent system is listed for use with your fireplace model prior
to starting the installation.
This vent kit may be installed as an OEM installation in a
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer’s instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240 MH.
CAUTION
All Fireplaces listed for use with the DvvK-4Fv will oper
-
ate safely when installed in accordance with this instruction
manual. Read all instructions before starting installation, then
follow these instructions carefully to maximize fireplace per
-
formance and safety. Report damaged parts to your dealer.
WARNING
Any common venting of the gas appliance using the DV
vent kit with other gas appliances is not allowed. Do not
connect this appliance to a chimney flue servicing a sepa
-
rate solid fuel-burning appliance.
WARNING
Failure to follow these instructions may create a possible
fire hazard and will void the warranty.
WARNING
Always maintain minimum clearances around vent sys-
tems. The minimum clearance to combustibles for horizon
-
tal runs of vent pipe is 3 inches from the top, and 1 inch
from the sides and bottom of the vent system. Do not pack
the open air spaces around the fireplace or flue with insula
-
tion or other materials. Any horizontal run must have a 1/4”
rise for every one foot of run towards the vent termination.
The vent above the roof must terminate vertically.
WARNING
Contact your Local Building and Fire Officials about restric
-
tions and installation inspections in your area.
IMPORTANT SAFETY INFORMATION
•
The vertical termination cap MUST be vented directly to the
outside. The termination kit MUST NEVER be connected to a
chimney flue(s) servicing a separate solid-fuel burning appli
-
ance or any other appliances.
•
Termination cap MUST NOT be mounted horizontally.
•
The flexible vent pipe cannot be intermingled with any of the
rigid vent pipe section(s). DO NOT connect two sections of
flexible vent pipe together to achieve a longer length without
the use of approved connectors.
•
The installation must conform with local codes or in the ab
-
sence of local codes, with the National Fuel Gas Code, ANSI
Z223.1 (in the United States) or with the current installation
code CAN/CGA B149 (in Canada).
•
Only Direct Vent fireplaces approved for use with Empire
Comfort Systems, Inc. DVVk-4FV termination kit shall be
used. See PARTS LIST/ILLUSTRATIONS section for vent
component identification.
•
Horizontal vent runs must be supported every 2 feet using
wall straps. Vertical runs must be supported every 3 feet using
wall straps. Slip wall straps loosely on to pipe. Attach installer
provided straps to framing members using nails or screws.
•
The fireplace and venting system should be inspected before
initial use and at least annually by a qualified field service per
-
son. Inspect the external vent cap on a regular basis to make
sure that no debris is interfering with the airflow. Inspect entire
venting system to ensure proper function.
•
Please refer to the fireplace instructions for information on
Termination Cap clearances.