FINISHING INSTALLATION
Use non-combustible materials where indicated for the fireplace
installation. Non-combustible materials do not ignite or burn
as a result of using the fireplace. These include metal, brick,
ceramic, concrete, slate, glass and plaster. Adhesives must be
rated for high temperatures. Any mechanical fasteners used
to install material must also be non-combustible, including wall
anchors and tile spacers. Materials that pass the ASTM E 136
test (Standard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750C) are considered non-combustible.
Figures 6 - 9
on Pages 12 and 13 shows the minimum vertical
and corresponding maximum horizontal dimensions of mantels
or other combustible projections above the top front edge of the
fireplace.
Only non-combustible materials may be used to cover the black
fireplace front.
WARNING
When finishing the fireplace never obstruct or modify the
air inlet/outlet louvers in any manner. Provide adequate
clearances around air openings into the combustion
chamber.
CAUTION
If the joints between the finished wall and the fireplace
surround (top and sides) are sealed, a 300 Degree F
minimum sealant material must be used. These joints are
not required to be sealed. Only non-combustible material
(using 300 Degree F minimum adhesive if needed), can be
applied as facing to the fireplace surround.
NON-COMBUSTIBLE
BOARD
FINISHED
WALL
FINISHED
WALL
FINISHED
WALL
NON-COMBUSTIBLE
WALL COVERING
(300° MIN.
ADHESIVE
REQUIRED)
Figure 59
Содержание MILLIVOLT DVCP36PP30N
Страница 45: ...LOG PLACEMENT LSU24SPF 36092 10 0619 Page 45...
Страница 66: ...36092 10 0619 Page 66 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 67: ...36092 10 0619 Page 67 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 71: ...36092 10 0619 Page 71 This page intentionally left blank...