TOP EXIT- VERTICAL AND HORIZONTAL TERMINATION
(DIMENSIONS IN FEET)
VER
TICAL
DIMENSION FROM
THE BOTT
OM OF
THE UNIT
T
O
THE CENTER OF
THE FLUE OUTLET
WITH VER
TICAL
OR HORIZONT
AL
TERMINA
TION CAPS
HORIZONTAL RUN
REAR HORIZONTAL
VENT CONNECTION
To Use the Vent Graph
1. Determine the height of the center of the horizontal vent
pipe. Using this dimension on the Sidewall Vent Graph,
locate the point it intersects with the slanted graph line.
2. From the point of this intersection, draw a vertical line to
the bottom of the graph.
3. Select the indicated dimension, and position the unit in
accordance with same.
EXAMPLE A:
If the vertical dimension from the floor of the unit is 12 feet,
4 inches the horizontal run to the outer wall flange must not
exceed 12 feet, 3 inches.
EXAMPLE B:
If the vertical dimension from the floor of the unit is 6 feet, 9
inches, the horizontal run to the outer wall flange must not
exceed 6 feet, 6 inches.
SPECIAL NOTE:
For each 45 degree elbow installed in the
horizontal run, the length of the horizontal run MUST be
reduced by 18 inches (457 mm). This does not apply if the
45 degree elbows are installed on the vertical part of the vent
system. Reduce three feet for every 90° elbow.
Example:
According to the chart the maximum horizontal vent
length is 20 feet and if two 45 degree elbows are required in the
horizontal vent it must be reduced to 17 feet.
The maximum number of 45 degree elbows permitted per side
wall installation is two. These elbows can be installed in either
the vertical or horizontal run.
NOTICE:
When rear venting unit, adjust air shutter according
to the table below.
Acceptable vertical and horizontal vent run.
Unacceptable vertical and horizontal vent run.
NOTICE:
When rear venting unit, adjust air shutter according to
the requirements in
Table 1
.
Adjust air shutter from 1/4" open to between 5/16" and 3/8" for
Propane Gas.
Figure 40
Venting Graph (Dimensions in Feet)
VENTING FIREPLACE - REAR
AIR SHUTTER OPENINGS
(DIMENSIONS IN INCHES)
Model
Top Venting Rear Venting
Gas Type
DVCD32
1/16
1/8 to 3/16
Natural
DVCD36
1/16
1/8 to 3/16
Natural
DVCD42
3/16
1/4 to 5/16
Natural
DVCD32
1/4
5/16 to 3/8
Propane
DVCD36
5/16
3/8 to 7/16
Propane
DVCD42
5/16
3/8 to 7/16
Propane
Table 1
Содержание MILLIVOLT DVCD FP3-4 Series
Страница 47: ...Page 47 38712 4 0920 7 Tuck Log G under Log C and onto pin of Log B LOG PLACEMENT FOR DVCD32 FIREPLACES...
Страница 48: ...38712 4 0920 Page 48 Log placement is complete LOG PLACEMENT FOR DVCD32 FIREPLACES...
Страница 57: ...Page 57 38712 4 0920 LOG PLACEMENT FOR DVCD36 FIREPLACES Log placement is complete...
Страница 67: ...Page 67 38712 4 0920 Log placement is complete LOG PLACEMENT FOR DVCD42 FIREPLACES...
Страница 93: ...Page 93 38712 4 0920 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 94: ...38712 4 0920 Page 94 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 95: ...Page 95 38712 4 0920 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...