PLEASE NOTE

:  When ordering parts, it is very important that part number and description of part coincide.

PARTS LIST

 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

INDEX 

NO.

PART 

NO.

DESCRIPTION

1

25207

PANEL - TOP

2

21595

CONDENSATE TRAY

3

252223

LOUVER - TOP

4

25212

REAR BURNER TRAY

5

R9987

FLEX LINE

6

26081

FRONT BURNER TRAY ASSEMBLY

7

25205

PANEL - LEFT SIDE

8

21605

INLET AIR DUCT COVER

9

21604

INLET AIR DUCT

10

R8810

INLET AIR DUCT GASKET

11

R8825

SOLENOID

12

R10072

GAS SHUT OFF VALVE

13

R8812

VALVE - NAT

14

26077

GLASS ASSEMBLY

15

25208

BOTTOM PAN

16

22778

AIR CIRCULATOR ASSEMBLY

17

R8817

TERMINAL STRIP

18

R10338

PRESSURE SWITCH

19

25227

ELECTRICAL PARTS PLATE

20

R10074

CONTROL BOX

21

R8889

TRANSFORMER 12-24V

22

R8881

CAPACITOR 3uF

23

R8880

CAPACITOR 4uF

24

R8804

TRANSFORMER - 24V

25

R10079

CONDENSATE PUMP BOX

26

R8832

CONDENSATE PUMP

27

R10080

CONDENSATE PUMP LID

28

25226

CIRCUIT BOARD PLATE

29

R8809

DOUBLE ROCKER SWITCH

30

R8876

LOCK OUT SWITCH

31

R8904

CIRCUIT BOARD

32

26083

FRONT BURNER ASSEMBLY

33

26082

BACK BURNER ASSEMBLY

34

R10082

ORIFICE HOLDER

35

22865

HOT SURFACE IGNITOR  

(2 REQUIRED)

36

R8807

FLAME SENSOR (2 REQUIRED)

37

25210

AIR DUCT CHANNEL

38

25214

PANEL - RIGHT SIDE

39

25221

FIREBOX BASE

40

25222

DOOR BRACKET (2 REQUIRED)

41

R4053

DOOR CLAMP (2 REQUIRED)

42

25225

LATCH BRACKET (2 REQUIRED)

43

25215

BAFFLE

44

26080

FIREBOX ASSEMBLY

45

26087

SUMP ASSEMBLY

46

R8799

INDUCER WHEEL

47

R8798

INDUCER MOTOR

48

26089

FLEX PIPE ASSEMBLY

49

26090

FIN TUBE ASSEMBLY

50

R8811

INLET HEADER GASKET

51

25204

PANEL - BACK

52

R8793

ORIFICE HOLDER

53

R10182

WIRE HARNESS - 120V

54

R10190

WIRE HARNESS - 12V SMALL

55

R10183

WIRE HARNESS - 12V LARGE

56

R8814

THERMISTER

57

R9487

REMOTE WIRE ASSEMBLY

58

R8872

WIRE HARNESS

59

R8905

RIBBON CABLE

60

24831

REAR HEAT SHIELD ASSEMBLY

61

22642

CONDENSATE PUMP TUBE

62

25325

CONDENSATE PUMP COVER

63

R8874

INDUCER, TOP SCROLL

64

R10077

LOG SET

64

R10376

REAR LOG

65

R10381

LEFT LOG

66

R10380

RIGHT LOG

67

R10379

MIDDLE LOG

68

R10378

FRONT LEFT LOG

69

R10377

FRONT RIGHT LOG

70

R10383

LEFT TOP LONG LOG

71

R10382

RIGHT TOP SHORT LOG

NOT 

SHOWN

R10093

ORIFICE #47 - NAT

NOT 

SHOWN

R10094

ORIFICE #49 - NAT

NOT 

SHOWN

R10095

ORIFICE #1.2MM - LP

NOT 

SHOWN

R10096

ORIFICE #55 - LP

NOT 

SHOWN

26117

AIR DUCT CHANNEL COVER PLATE - 

NAT ONLY

INDEX 

NO.

PART 

NO.

DESCRIPTION

Содержание Mantis FF28BMN-1

Страница 1: ...as supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified ins...

Страница 2: ...23 Horizontal Examples for Colinear Direct Vent 24 Vertical Examples for Colinear Direct Vent 25 27 PVCA Horizontal Colinear Direct Vent Adaptor 28 PVVTC Termination Cap Vent Kit 29 PVCT Colinear Tra...

Страница 3: ...d control compartment clean Vent cap hot while furnace is in operation For manufactured home USA only or mobile home or residential installation convertible for use with natural gas and liquefied petr...

Страница 4: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Страница 5: ...sions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimu...

Страница 6: ...ressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in...

Страница 7: ...372 m without change Attention This appliance is NOT to be installed in Canada Introduction Always consult your local Building Department regarding regulations codes or ordinances which apply to the...

Страница 8: ...e i e wood metal concrete Please Note Rough or uneven surfaces can cause vibration or humming in the heater 4 The Mantis Power Vent High Effeciency Fireplace can be installed in a wide variety of ways...

Страница 9: ...12 305 mm above grade and must be vented outside WARNING The nearest point of the vent cap should be a minimum horizontal distant of six 6 feet 1 83 m from any pressure regulator In case of regulator...

Страница 10: ...or In case of regulator malfunction the six 6 feet 1 83 m distance will reduce the chance of gas entering the vent cap Installation on Rugs and Tile If this appliance is to be installed directly on ca...

Страница 11: ...odel PVVK SH required FWK28 BL CM HP SS Contains surround hood and lower front 35 88 9cm 33 7 16 84 9cm 25 3 8 64 5cm 17 43 2cm 23 7 8 60 6cm 1 FLUE OUTLET 2 AIR INLET 3 ELECTRIC CORD 4 FLEX HOSE OPEN...

Страница 12: ...16 18 6cm 4 3 16 10 6cm 2 5 8 6 7cm 6 1 8 15 6cm 3 9 16 9 0cm 13 16 2 1cm 1 2 5cm 17 43 2cm 3 9 16 9 0cm 1 FLUE OUTLET 5 SINGLE FLUE ADAPTOR MODEL PVVK SH Figure 4 Heater 35 Surround Kit 1 Flue Outlet...

Страница 13: ...38 96 5cm 30 7 8 78 4cm 25 3 8 64 5cm 24 5 8 62 5cm 17 43 2cm 3 9 16 9 0cm 1 FLUE OUTLET 5 SINGLE FLUE ADAPTOR MODEL PVVK SH Figure 5 Heater 38 Surround 1 Flue Outlet 1 1 2 PVC Pipe 2 Air Inlet 3 Elec...

Страница 14: ...approved for zero clearance to combustible materials Empire Comfort Systems Inc recommends that clearances as listed above should be maintained to allow for removal of the product for servicing Figur...

Страница 15: ...G PVVK 24H PVVK 48H 23 1 2 when using 90 elbow for ver tical venting NOTE DIMENSIONS FOR USE WITH SHORT TOP PV4H THIS IS RECOMMENDED FOR UNIT SERVICEABILITY B 24 3 4 C 28 3 16 A 23 1 2 WHEN USING FI28...

Страница 16: ...25700 1 0809 Page 16 WALL CLEARANCES 35 88 9cm 29 3 8 74 6cm 25 3 8 64 5cm 24 5 8 62 5cm 23 1 2 59 7cm 6 16 5cm PVVK SH PVVK CFA Figure 13...

Страница 17: ...Front Right Log fits over the front Flame sensor See Figure 14A 5 Place Front Left Log E on left side of Firebox bottom Notch in bottom of Front Left Log fits over front Hot Surface Ignitor See Figur...

Страница 18: ...contains the following Index Letter Log Description A Rear Log B Left Log C Right Log D Middle Log E Front Left Log F Front Right Log G Left Top Log H Right Top Log A Rear Log B Left Log C Right Log...

Страница 19: ...outside wall is 6 15 2 cm See Figure 17 Minimum vent from the rear of the unit is 12 Note Horizontal discharge 90 elbow must be pointed downward See Figure 18 All horizontal runs require either a 1 4...

Страница 20: ...0 FLEXIBLE VENT KIT WITH 1 1 2 COUPLING ON EACH END MODEL PVVK CFA FLEXIBLE GAS LINE PVC PIPE SWV SUPPLIED BY INSTALLER 2 45 DEG PVC BENDS SUPPLIED BY INSTALLER IF NECCESSARY GALV SHEET FLASHING TO SE...

Страница 21: ...height above the rooftop These minimum heights are necessary in the interest of safety These specifications are summarized in Figure 22 MANTEL PVC PIPE SUPPLIED BY INSTALLER 2 45 DEG PVC BENDS SUPPLIE...

Страница 22: ...VC joints of the flex vent kit to the remaining PVC vent run FLEXIBLE FLUE KIT FLEXIBLE GAS LINE PVC PIPE SWV SUPPLIED BY INSTALLER 2 45 DEG PVC BENDS SUPPLIED BY INSTALLER IF NECCESSARY GALV SHEET FL...

Страница 23: ...with four 4 screws Note No PVC cement is needed to install flue adaptor kit 3 Install plastic gasket and screw threaded connector to the flue adaptor When these connections are made continue with you...

Страница 24: ...ure 29 Note Horizontal discharge 90 elbow must be pointed downward See Figure 31 All horizontal runs require either a 1 4 per foot rise to run condensation back to the heater or a 1 4 per foot downwar...

Страница 25: ...m Vent Height Above the Roof WARNING Major U S building codes specify minimum chimney and or vent height above the rooftop These minimum heights are necessary in the interest of safety Special Note Th...

Страница 26: ...X HEIGHT FLASHING REQUIRED HEIGHT AIR INTAKE PTRAP 2 90 ELBOWS SUPPLIED BY INSTALLER OR TERMINATION CAP MODEL PVVTC PTRAP TO FACE AWAY FROM ROOF EXHAUST TERMINATION CAP MODEL PVVTC PTRAP OR 2 90 ELBOW...

Страница 27: ...and intake air cap pipes with any of the following Vertical termination cap model PVVTC PTrap or two 90 elbows When transition plate model PVCT is used two termination caps model PVVTC may NOT be used...

Страница 28: ...nnected continue with your vent run Cementing PVC joint is recommended but not required on colinear fresh air intake adaptor Figure 36 Colinear adaptor Colinear adaptor to be used in conjunction with...

Страница 29: ...ble from Empire Comfort Systems Inc Figure 40 Termination Cap Vertical exhaust cap used with 1 1 2 PVC pipe installation Termination cap also used with colinear transition plate model PVCT Refer to in...

Страница 30: ...SEALER REQUIRED OPTIONAL CAP MODEL PVVTC ORDER SEPARATE EXHAUST 3 MIN HEIGHT MIN 12 Horizontal Application 1 Attach plate to outside wall with four 4 screws Use outdoor sealant to seal transition pla...

Страница 31: ...de Dimension Installation on Rugs and Tile If this appliance is to be installed directly on carpeting tile or other combustible material other than wood flooring the appliance shall be installed on a...

Страница 32: ...nnection between co axial adaptor and co axial air inlet duct Step 5 Slide co axial vent pipes into co axial adaptor Cut the PVC co axial pipes at this time Minimum horizontal vent length 4 1 2 11 4 c...

Страница 33: ...Figure 58 Direct Vent System Building Exterior View 1 5 4 3 2 Parts List Index Number Part Number Description 1 R8887 Co axial DV Adaptor 2 R8862 Foam Gasket 3 22616 Co axial duct assembly 4 R8888 24...

Страница 34: ...le to prevent movement Note The gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from its location for servicing of the heater For firep...

Страница 35: ...the surround as shown in Figure 61 on the flat front heater as shown in Figure 62 and fasten to the heater with the four screws provided at points A B C and D Note See page 45 General Glass Informati...

Страница 36: ...tted in line with the manufacturer s specifications as illustrated in this manual pages 11 to 31 7 Do not use alternative Flue or cap on installation other than that specified in this manual otherwise...

Страница 37: ...flame there which will become more visible as the heater warms up Once the heater warms up the low speed L E D Figure 66F will light and the convection fan will blow warm air from the heater As the he...

Страница 38: ...gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat if used to the lowest setting 3 Turn off all electric power to the appliance...

Страница 39: ...only low fan speed b Rear burner only medium fan speed c Both front and rear burners high fan speed On changing the burner setting from high to medium or from high to low there will be a delay on the...

Страница 40: ...midifier can operate from approximately 10 minute to 6 hour intervals depending on ambient temperature style and type of flue Long single vertical flues can cause the humidifier to come on more often...

Страница 41: ...it into outlet Turn both burner switches to the ON position Burner switches must remain in the ON position for remote to function Set remote from the instructions provided with the remote control Set...

Страница 42: ...d When using a controller both burner switches need to be in the ON position When the red button is pressed with both burner switches on the front burner only will ignite or if already alight it will...

Страница 43: ...The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code C...

Страница 44: ...ting season and if necessary have it serviced by a qualified service technician refer to Pages 45 to 47 Maintenance Paint Curing First Firing The first fire in your heater is part of the paint curing...

Страница 45: ...wo or three times during each heating season depending on the circumstances present General Glass Information Only glass approved for use in Empire Comfort Systems Inc fireplace may be used for replac...

Страница 46: ...to 18 16 Replace glass assembly See page 45 17 Replace lower louver door 18 Reconnect power cord to electricity Removal and replacement of Rear Hot Surface Ignitor HSI 1 Unplug power cord from electri...

Страница 47: ...screw removed in Step 5 11 Secure junction block to blower with one 1 5 16 screw removed in Step 4 12 Secure control assembly to Mantis bottom with two 2 5 16 screws removed in Step 3 13 Close lower...

Страница 48: ...uld not allow for easy removal of the appliance to carry out routine inspection and service work on the appliance DISCONNECT MAIN POWER PRIOR TO STARTING ANY WORK ON THE APPLIANCE UNIT OPERATING FAULT...

Страница 49: ...minated If you have a Remote burner switch and the rear burner L E D should start flashing with the flue fan L E D remaining steady Wait approximately 60 seconds for the rear burner to ignite You can...

Страница 50: ...Y 33 26082 BACK BURNER ASSEMBLY 34 R10082 ORIFICE HOLDER 35 22865 HOT SURFACE IGNITOR 2 REQUIRED 36 R8807 FLAME SENSOR 2 REQUIRED 37 25210 AIR DUCT CHANNEL 38 25214 PANEL RIGHT SIDE 39 25221 FIREBOX B...

Страница 51: ...TS VIEW 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 61 20 21 22 23 24 25 54 55 56 57 59 58 53 26 27 28 29 30 31 32 62 33 37 38 39 60 40 43 44 49 45 46 47 48 63 51 50 41 42 42 41 40 36 10 35 35 34 52...

Страница 52: ...The heating appliance must be installed by a qualified installer and operated in accordance with the written instructions furnished with the appliance Ready access to the appliance for service is the...

Страница 53: ...Parts Heater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites w...

Страница 54: ...25700 1 0809 Page 54 SERVICE NOTES...

Страница 55: ...25700 1 0809 Page 55 SERVICE NOTES...

Страница 56: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: