RESETTING THE HEATER
There are a number of reasons why sometimes the heater will
switch itself off and is the correct thing for the heater to do in
certain situations (i.e. overheating, power failure or dips, windy
conditions, pump failure, partial or full blockage of flue pipe or
no gas. All of these operations are monitored by the electronic
control box inside the heater, which is heat sensitive, pressure
switch sensitive, flame sensitive and water sensitive. If one of
these items is not correct, the heater will shut itself down.
To reset, turn both burner switches to the OFF position, ensure the
red button above the two burner switches is not illuminated (if a
Remote Control is fitted, have it in the off mode). Then turn the
power off at the power point for approximately 10 seconds. Then
turn the power point back on and the power L.E.D. should be
illuminated. If you have a Remote burner switch and the rear
burner L.E.D. should start flashing, with the flue fan L.E.D.
remaining steady. Wait approximately 60 seconds for the rear
burner to ignite. You can tell when it has lit, even if you can’t see
any flames, by looking at the rear burner L.E.D. which should
remain steady. Repeat the same process with the front burner. Turn
on the front burner switch and wait approximately 60 seconds and
the front burner L.E.D. will remain steady.
In approximately 5 minutes the convection fan should start and
the heater has been successfully reset.
Note:
if the heater is still warm when reset the convection fan
may already be running when the unit is powered up.
LOG REPLACEMENT
If for any reason a log should need replacement, you must use the
proper replacement log. Consult your Mantis dealer for correct
replacement logs.
Replacement logs must be installed and positioned as outlined on
pages 17 to 18 under Log Installation.
Note:
Improper positioning of logs can create carbon build up
and will alter the unit’s performance and operation.