GAS CONNECTION INSTALLATION INSTRUCTIONS
GAS CONNECTION (Line Supply)
A 3/8” Flair gas line connection is supplied in the heater
GAS SUPPLY LINE TO HEATER
1.
Pull flex line through top hole in back panel.
2.
Connect gas supply line to flexible gas hose. Ensure that flexible gas hose is not kinked after fitting gas supply line.
3.
Push excess flex line back into heater and place rubber grommet (supplied in hardware packet) over gas line at hole to prevent
movement.
Note:
The gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from its
location for servicing of the heater. For fireplace insert installations, incorporate either a copper loop into the supply line or flexible hose
being used for the gas supply to the heater to allow for easy removal of the appliance.
Note:
Under no circumstances should the gas supply line to the appliance be installed under conditions, which would not allow for
easy removal of the appliance to carry out routine inspection and service to the appliance.