Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you 

can smell the odorant in propane.

 Smoking can decrease your 

ability to smell. Being around an odor for a time can affect your 

sensitivity or ability to detect that odor. Sometimes other odors 

in the area mask the gas odor. People may not smell the gas odor 

or their minds are on something else. Thinking about smelling a 

gas odor can make it easier to smell.

The odorant in LP-gas is colorless, and it can fade under some 

circumstances. 

For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants 

in LP-Gas also are subject to oxidation. This fading can occur if 

there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, 

masonry and other materials and fabrics in a room. That will take 

some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precau

-

tions which can protect both you and your family from an 

accident. Read them carefully now, then review them point 

by point with the members of your household. Someday when 

there may not be a minute to lose, everyone's safety will depend 

on knowing exactly what to do. If, after reading the following 

information, you feel you still need more information, please 

contact your gas supplier.

• 

Learn to recognize the odor of LP-gas. 

Your local LP-Gas 

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

•  If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

•  Sometimes a basement or a closed-up house has a musty smell 

that can cover up the LP-Gas odor. Do not try to light pilot 

lights, perform service, or make adjustments in an area where 

the conditions are such that you may not detect the odor if there 

has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been out 

of service for a time may develop internal rust which will cause 

odor fade. If such conditions are suspected to exist, a periodic 

sniff test of the gas is advisable. 

If you have any question about 

the gas odor, call your 

LP

-gas dealer. 

A

 periodic sniff test of 

the LP

-gas is a good safety measure under any condition.

•  If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

•  If you experience a complete "gas out," (the container is under 

no vapor pressure), turn the tank valve off immediately. If the 

container valve is left on, the container may draw in some air 

through openings such as pilot light orifices. If this occurs, some 

new internal rusting could occur. If the valve is left open, then 

treat the container as a new tank. Always be sure your container 

is under vapor pressure by turning it off at the container before 

it goes completely empty or having it refilled before it is com

-

pletely empty.

•  Do not operate electric switches, light matches, use your phone. 

Do not do anything that could ignite the gas.

•  Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•  Close all gas tank or cylinder supply valves.

•  LP-Gas is heavier than air and may settle in low areas such as 

basements. When you have reason to suspect a gas leak, keep 

out of basements and other low areas. Stay out until firefighters 

declare them to be safe.

•  Use your neighbor's phone and call a trained LP-Gas service 

person and the fire department. Even though you may not con

-

tinue to smell gas, do not turn on the gas again. Do not re-enter 

the building, vehicle, trailer, or area.

• 

Finally

, let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then check 

and relight the gas appliance for you.

SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS wARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. 

That's your signal to go into immediate action!

SAFETy INFORMATION FOR USERS OF LP-GAS

Содержание FLINT HILL VFDM18LBN-1

Страница 1: ...ion An unvented room heater produces approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Refer to page 6 Thisappliancemaybeinstalledinanaftermarketpermanently loc...

Страница 2: ...og Placement 7 Log Set 15 Operation Instructions Flame Appearance 16 Wiring VFDR Models Only 17 VFDR 18 24 30 LB Lighting Instructions 18 VFDR18LB10 N P Lighting Instructions 19 VFDT 18 24 30 LB Light...

Страница 3: ...nly allow operation of this appliance in a vented configuration Check your state or local codes Correct installation of logs properlocation of the heaterand annual cleaning are necessary to avoid pote...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on...

Страница 5: ...ce 3 Installer should show owner how to start and operate unvented room heater vented decorative appliance Always consult your local Building Department regarding regulations codes or ordinances which...

Страница 6: ...re Max Gas Inlet Pressure Minimum VFDR 18 24 30 LB Natural Millivolt 3 5 W C 10 5 W C 4 5 W C Propane 10 0 W C 13 0 W C 11 0 W C VFDR18LB10 Natural Millivolt 3 5 W C 10 5 W C 5 0 W C Propane 10 0 W C...

Страница 7: ...x 1 2 black sheet metal anchoring screws Ceramic Log Set 5 Piece on VFDR 18 24 VFDT 18 24 and VFDM 18 24 7 Piece on VFDR30 VFDT30 and VFDM30 Plastic bag containing glowing embers rock wool for burner...

Страница 8: ...upplied for use with the log set 6 Also refer to IMPORTANT SAFETY INFORMATION on page 3 of this manual WARNING DO NOT OPERATE THIS GAS LOG SET WITH GLASS DOORS CLOSED Clothing or other flammable mater...

Страница 9: ...al Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8m3 per kw of the aggregate input rating of all appliances installed in that space...

Страница 10: ...or 18 24 and 30 logs from the fireplace opening Mantel Clearances Without Hood Figure 4 You must have non combustible materials above the fireplace opening Non combustible material must extend at leas...

Страница 11: ...factory built fireplaces Free opening area of chimney damper for venting combustion products from decora tiveappliancesforinstallationinsolidfuel burning fireplaces Height is from hearth to top of chi...

Страница 12: ...l the chimney flue damper Before installing in a solid fuel burning fireplace the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner You mus...

Страница 13: ...ed on the bottom in which condensation and foreign particles may collect Figure 11 The use of the following gas connectors is recommended ANSZ21 24ApplianceConnectorsofCorrugatedMetalTubing and Fittin...

Страница 14: ...second from the left EMBER MATERIAL PLACEMENT ON BURNER 5 After all logs are positioned properly apply Rockwool ember material to the front burner port area To apply carefully separate the ember mate...

Страница 15: ...front twig to the back side of the grate tang 4th one from the left 5 Place the rear twig 7 onto flat area of rear log 5 and over the front of the front twig Ember Material Placement on Burner 6 After...

Страница 16: ...smoke and smells as they are burned off during the initial operation of the appliance possibly causing headaches or eye or lung irritation This is a normal and temporary occurrence The initial break...

Страница 17: ...od you can release the gas control knob and the pilot will stay ON Allow your pilot flame to operate an additional one 1 to two 2 minutes before you turn the gas control knob from the PILOT position t...

Страница 18: ...4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slight...

Страница 19: ...ON switch to OFF 3 Turn off all electric power to the appliance if applicable 4 Open bottom louver assembly if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot...

Страница 20: ...ety information above If you do not smell gas go to the next step 6 Find pilot the pilot is located in front of the rear log 7 Turn manual gas control knob coun terclockwise to PILOT 8 Push in manual...

Страница 21: ...ar out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 4 Find pilot the pilot is located...

Страница 22: ...uching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down Correct Pilot Flame Pattern for VFDR Figure 21 Correct Pilot Flame Pattern for VF...

Страница 23: ...clean will result in sooting and poor combustion ANNUALCLEANING INSPECTION Referto parts diagram for location of items discussed below Inspect and clean burner air intake hole Remove lint or particles...

Страница 24: ...ed f Gas regulator setting is not correct Replace gas regulator 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Co...

Страница 25: ...Parts Heater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites w...

Страница 26: ...1561 21561 21561 TUBING ASSEMBLY VALVE TO PILOT LPG 12 21559 21559 21559 TUBING ASSEMBLY REGULATOR TO PILOT NAT 13 R7063 R7063 R7063 REGULATOR NAT PILOT 14 21560 21560 21560 TUBING ASSEMBLY VALVE TO R...

Страница 27: ...13 17 18 19 20 23 24 1 2 3 4 5 6 7 8 9 10 11 12 14 13 17 18 19 20 23 24 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 13 17 18 19 20 21 22 23 24 18 BURNER 24 BURNER 30 BURNER 32 27 30 28 29 27 28 29 30 32 33 31...

Страница 28: ...SHUTTER 7 R7572 JAMB NUT 8 21669 BURNER BASE SUB ASSEMBLY 9 21581 LEG REAR 2 REQUIRED 10 P214 ORIFICE NAT 10 P193 ORIFICE LPG 11 P212 ORIFICE HOLDER 12 21561 TUBING ASSEMBLY VALVE TO PILOT LPG 13 2156...

Страница 29: ...27439 1 0510 Page 29 1 2 3 4 5 6 7 8 9 10 11 12 15 16 17 20 21 18 BURNER 28 24 27 25 26 5 PIECE LOG SET 13 14 18 19 22 23 VFDR18LB10 PARTS VIEW...

Страница 30: ...0 P181 P257 P184 ORIFICE NAT 10 P258 P298 P300 ORIFICE LPG 11 P212 P212 P212 ORIFICE HOLDER 12 22633 22633 22633 TUBING ASSEMBLY VALVE TO PILOT LPG 12 R2479 R2479 R2479 TUBING ASSEMBLY REGULATOR TO PI...

Страница 31: ...32 33 31 7 PIECE LOG SET 32 27 30 28 29 5 PIECE LOG SET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 18 21 22 18 BURNER 24 BURNER 30 BURNER 23 16 15 1 2 3 4 8 5 6 7 9 10 11 15 12 13 14 17 18 16 21 22 23 1 2 3...

Страница 32: ...10 P258 P298 P299 ORIFICE LPG 11 P212 P212 P212 ORIFICE HOLDER 12 23109 23109 23109 TUBING ASSEMBLY VALVE TO PILOT NAT 12 23110 23110 23110 TUBING ASSEMBLY REGULATOR TO PILOT LPG 13 R2479 R2479 R2479...

Страница 33: ...10 23 1 2 3 4 5 6 7 8 9 10 11 12 17 23 1 2 3 4 5 6 7 8 9 10 21 22 23 18 BURNER 24 BURNER 30 BURNER 32 27 30 28 29 27 28 29 30 32 33 31 5 PIECE LOG SET 7 PIECE LOG SET 25 18 13 21 22 25 21 22 25 15 11...

Страница 34: ...eater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwweb...

Страница 35: ...27439 1 0510 Page 35 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 36: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: