background image

34961-2-1015

Page 27

BLOWER REMOVAL/REPLACEMENT

14.  Slide the burner to the right and lift out.

 See Figure 46.

 

NOTICE: 

Sliding the burner to the right ensures that the 

orifice disengages from the venturi. 

Figure 46

15.  Remove the two screws securing the “air box” to the rear of 

the firebox. Remove the “air box” and set aside. 

See Figure 

47.

Figure 47

16.  Remove the 18 screws securing the blower access panel to 

the firebox and set aside. Remove the blower access panel 

and set aside. 

See Figure 48.

Figure 48

17.  Pull blower far enough through the blower access hole to 

disconnect the wires at the connectors. 

See Figure 49. 

Once 

the wires are disconnected, remove blower completely and 

discard.

Figure 49

19.  Install the replacement blower, and re-install the insert by 

reversing the above steps.

Содержание DXL30IN91N-2

Страница 1: ...ch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you c...

Страница 2: ...ts 1 2 3 4 6 7 8 5 BEFORE YOU START 1 Read the safety information on Pages 32 33 2 Install the wiring See page 18 3 Install the venting See pages 9 11 4 Install the fireplace See pages 9 11 5 Connect...

Страница 3: ...14 BURNER COVER REMOVAL PLACEMENT 15 DECORATIVE MEDIA PLACEMENT 16 LIGHTING INSTRUCTIONS 17 IPI SYSTEM WIRING DIAGRAM 18 REMOTE CONTROL OPERATION INSTRUCTIONS 19 24 INSERT MAINTENANCE AND SERVICE 25...

Страница 4: ...with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from theAmerican National Standards Institute Inc 11 West 42nd St New Yo...

Страница 5: ...Model Description Used On DS3066BL 3 Sided 1 Piece Matte Black DXL30IN DS3566BL 3 Sided 1 Piece Matte Black DXL35IN REFLECTIVE LINERS Model Description Used On DVP30CKR Black 30 Inch DXL30IN DVP30CWR...

Страница 6: ...irements Proper opening size of fireplace required for installation of the fireplace insert INSERT DIMENSIONS in inches DIMENSION DXL30IN DXL35IN A 20 1 8 24 1 16 B 29 3 8 33 3 8 C 18 5 8 21 3 4 D 15...

Страница 7: ...m Face of Fireplace dimensions in inches Height Above Top of Insert dimensions in inches A 10 F 14 B 8 G 17 1 2 C 6 H 21 1 2 D 3 I 24 1 4 E 1 2 J 27 The minimum distance to the room ceiling from the T...

Страница 8: ...size or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied pe...

Страница 9: ...e the exposed grille area should be left open NOTICE Surround panel kits have been tested and approved to cover existing air circulation vents or grilles NOTICE Cutting of sheet metal parts of a firep...

Страница 10: ...a zero clearance factory built wood burning fireplace the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily Con...

Страница 11: ...34961 2 1015 Page 11 VENTING AND INSTALLATION Figure 9...

Страница 12: ...n the flex venting and subsequently dripping out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having exterior portio...

Страница 13: ...ssembly Figure 13 5 Repeat step 4 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of the clip while pulling injury may occur Ensure that the latch tool i...

Страница 14: ...pull the latch out and up until it engages to the glass assembly Figure 16 5 Repeat step 4 through 5 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of...

Страница 15: ...urner cover out from the back past the front of the unit Tilt the burner cover to the side and lift out See Figures 19 and 20 Set the burner cover aside Figure 19 Figure 20 Note Install firebox liners...

Страница 16: ...2 3 Bag or 1lb 10 oz 1 Bag or 2 lbs DXL30IN LP Approximately 2 3 Bag or 1lb 10 oz 1 Bag or 2 lbs DXL35IN NAT 3 4 Bag or 1lb 8 oz 2 Bags or 2 lbs 8 oz DXL35IN LP Not Allowed 2 Bags or 2 lbs 8 oz Contac...

Страница 17: ...tructions for detailed operation information LIGHTING INSTRUCTIONS A This appliance is equipped with an ignition device which au tomatically lights the pilot Do not try to light the pilot by hand use...

Страница 18: ...ed mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used CAUTION Do not operate the appliance with glass panel remov...

Страница 19: ...rature Ratings 0 50 C 32 122 F Radio Frequency 315 MHz NOTICE THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE RECEIVER IN OR NEAR METAL SEVERELY REDUCES THE SIGNAL RANGE NOTICE TU...

Страница 20: ...on Display With the system in the OFF position press the THERMOSTAT key and the MODE key at the same time Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of t...

Страница 21: ...sing the DOWN ARROW key once will reduce the flame height by one step until the flame is turned OFF The UP ARROW key will increase the flame height each time it is pressed If the UP ARROW key is press...

Страница 22: ...displayed on the LCD screen of the Transmitter Figure 33 SMART Thermostat Operation The Smart Thermostat function adjusts the flame height in accor dance with the difference between the set point temp...

Страница 23: ...off or adjust fan speed See Figures 25a and 36 A single beep will confirm reception of the command Figure 36 Fan Icon Figure 37 Fan Speed Control Activated Continuous Pilot Intermittent Pilot CPI IPI...

Страница 24: ...sing the Insert Without a Remote Control Remove the decorative front and outer surround to access the module With the ON OFF rocker switch in the ON position press with SW1 button on the module The mo...

Страница 25: ...ion Glass Cleaning It will be necessary to clean the glass periodically During start up condensation which is normal forms on the inside of the glass and causes lint dust and other airborne particles...

Страница 26: ...o screws securing the bottom flange to the firebox See Figure 43 6 Hand bend the flange so that lays flat See Figure 43 7 Remove blower from appliance and disconnect the wires at the connectors and di...

Страница 27: ...e the air box and set aside See Figure 47 Figure 47 16 Remove the 18 screws securing the blower access panel to the firebox and set aside Remove the blower access panel and set aside See Figure 48 Fig...

Страница 28: ...34961 2 1015 Page 28 DECORATIVE FRONTS...

Страница 29: ...be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number an...

Страница 30: ...11 R10424 R10424 PILOT ASSEMBLY LPG 12 31246 28917 PILOT SHIELD 13 31195 31196 GLASS FRAME ASSEMBLY 14 28943 28943 AIR BOX 15 28848 28848 BLOWER ACCESS PANEL 16 31247 31247 BLOWER BRACKET 17 R11534 R...

Страница 31: ...34961 2 1015 Page 31 20 19 18 17 16 15 14 21 22 23 24 7 6 8 12 11 10 4 3 2 1 13 5 25 26 EXPLODED VIEW...

Страница 32: ...th this appli ance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for...

Страница 33: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Страница 34: ...Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be...

Страница 35: ...34961 2 1015 Page 35 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 36: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...