1. To wire Junction Box Receptacle, remove the tab on the side of
the receptacle (hot side) to split receptacle. This will be required
to separate blower and valve circuits.
2. Power for switched and live sides of Duplex Receptacle must
come from the same power source. (One circuit breaker on
main panel must switch all power off.)
3. From the wall box to the fireplace a 3-wire conductor with
ground is recommended, however (2) two-wire conductors
with grounds may be used in place of a 3-wire conductor with
a ground if the black wires from the thermostat and blower
switch are identified.
4. Two wall switches, or a wall switch and thermostat may be
used to activate the two receptacle plugs independently.
The intermittent pilot (120/24 volt system) is ON when the main
burner is ON. When the main burner is OFF the intermittent pilot
is OFF.
The pilot flame should envelop 3/8 to 1/2 inch (10 to 13 mm) of the
tip of the flame rod.
To adjust:
1. Remove the pilot adjustment cover screw.
2. Turn the inner adjustment screw clockwise
to decrease
or counterclockwise
to increase pilot flame. Pilot ad
-
justment is shipped at full flow rate. Turn the inner adjustment
screw clockwise
if the inlet pressure is too high.
3. Replace the cover screw after the adjustment to prevent gas
leakage.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Figure 76
Provided on the intermittent pilot wiring harness are two (2) stripped
and bare wires that are labeled THERMOSTAT. The wires will be used
for attachment of 24 volt thermostat, optional FWS-1 wall switch or
will attach into the receiver on an optional FREC remote control.
Installation of Remote Receiver
Place remote receiver on the floor of fireplace behind the louver as
far forward as possible.
Attention:
The Velcro loop and hook are not necessary in this
installation but can be used to secure remote receiver.
ELECTRICAL CONNECTION (Figure 76)
The DVX Intermittent Pilot Models with optional fan requires 120
VAC electrical hookup to the electrical box (installed).
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the
National Electrical Code, ANSI/NFPA 70
, if an external electrical
source is utilized.
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED
ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LO
-
CAL, CITY AND STATE BUILDING CODES. BEFORE MAKING
THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN
POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN
INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCOR
-
DANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL
CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA
70 (LATEST EDITION).
Figure 77
INTERMITTENT PILOT OPERATING INSTRUCTIONS
INTERMITTENT PILOT WIRING DIAGRAM