Framing and Finishing
1. Choose unit location.
2. Frame in fireplace with a header across the top. It is important
to allow for finished face when setting the depth of the frame.
3. Attach fireplace to frame using adjustable nailing flange. Preset
depth to suit facing material (adjustable to 3/8", 1/2" or 3/4" depths).
Note: Fireplace must mount flush to facing material. If facing
material requires more depth than 3/4" mark and drill two (2) 1/8"
holes into fireplace side at appropriate depth. See
Figure 9.
4. Use (8) 1/2" hex-head screws supplied in hardware package,
to screw through slotted holes in drywall strip and then screw
into pre-drilled holes on fireplace side. Measure from face of
fireplace to face of drywall strip to determine final depth.
Figure 9
Vent Pipe Clearance
Note:
Maintain one inch (1") of clearance around vertical vent
pipe.
See Figure 11.
For horizontal vent, maintain a minimum 1"
clearance to the bottom and sides of the vent, and 3" clearance to
combustibles above the vent pipe.
See Figure 12.
Figure 11
VENT PIPE
1" MINIMUM CLEARANCE AROUND VENT PIPE
USE OUTER
(4) FLANGES
FOR 1/2”
DRYWALL