26408-0-1009
Page 11
Framing and Finishing
1. Choose unit location.
2. Frame in fireplace with a header across the top. It is important to
allow for finished face when setting the depth of the frame.
3. Attach fireplace to frame using adjustable nailing flange. Preset
depth to suit facing material (adjustable to 3/8", 1/2" or 3/4" depths).
Note: Fireplace must mount flush to facing material. If facing
material requires more depth than 3/4" mark and drill two (2)
1/8" holes into fireplace side at appropriate depth. Bend standoff
tabs as needed to move fireplace flush with facing material. See
Figures 8A and 8B.
4. Use (8) 1/2" hex-head screws supplied in hardware package,
to screw through slotted holes in drywall strip and then screw
into pre-drilled holes on fireplace side. Measure from face of
fireplace to face of drywall strip to determine final depth.
Figure 9A
vent pipe Clearance
Note:
Maintain one inch (1") of clearance around vertical vent pipe.
See Figures 9A and 9B.
For horizontal vent, maintain a minimum
1" clearance to the bottom and sides of the vent, and 3" clearance
to combustibles above the vent pipe.
See Figure 9A.
VENT PIPE
1" MINIMUM CLEARANCE AROUND VENT PIPE
Top of Vent
Combustibles NOT
allowed in shaded
area
1"
1"
3"
(25 mm)
7” Diameter
intake vent
4” Diameter flue
(25 mm)
(76 mm)
Figure 9B
INSTALLATION
Figure 8A
Figure 8B