VENT SYSTEM IDENTIFICATION
Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part
numbers and pricing.
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers.
DVVK-4VP
(DVVK-4V)
Direct-Vent Fireplace Vent Kit - Vertical, Includes 46DVA-VCH,
46DVA-SC and 46DVA-F6
DVVK-4TP
(DVVK-4T)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall,
8 to 11 inch wall thickness, Includes 46DVA-09, 46DVA-08A,
46DVA-HC, 46DVA-E90 and 46DVA-WT
DVVK-4TSP
(DVVK-4TS)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall,
5 to 7 inch wall thickness, Includes 46DVA-06, 46DVA-HC,
46DVA-E90 and 46DVA-WT
DVVK-4FV
Direct-Vent Fireplace Vertical Flex Vent Kit
DVVK-4RE
Direct-Vent Fireplace Vent Kit, Thru-the-wall, 5 to 13 3/4 inch
wall thickness
Notice:
Rear vent installation can only be vented on natural gas.
SPECIAL VENT SYSTEMS
The following vent systems are acceptable for use with the DVP36 series fireplaces:
Simpson Duravent® GS 4" - 6 ⅝"
American Metal Products 4" - 6 ⅝"
Selkirk Direct-Temp® 4" - 6 ⅝"
Security Secure Vent® 4" - 6 ⅝"
Excel DV Venting 4” - 6 ⅝”
Empire Horizontal Round Termination Kit DVVK-4RE
Empire Flexvent Kit DVVK-4F
Empire Flexvent Kit DVVK-4FV Vertical Flex Vent Kit
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NOTICE:
Some fireplaces cannot be vented out the rear of the
fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to
the “Special Vent Systems” section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use
Figure 21
on page 17 for top venting, or
Figure 33
on page
23 for rear venting to eliminate issues after installation. Check pipe
diameter on vent system and fireplace to verify the size is the same.
NOTICE
: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
Figure 1
*Note:
If using three 90° elbows during horizontal
termination, see
Figure 31.
Содержание DVP36DP31 Series
Страница 21: ...31451 2 1013 Page 21 Figure 30 Figure 31 Figure 32 EXAMPLES TOP VENT RUN...
Страница 37: ...31451 2 1013 Page 37 Figure 57 DVVK 4FV DIRECT VENT TERMINATION KIT...
Страница 47: ...31451 2 1013 Page 47 Figure 70 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 59: ...31451 2 1013 Page 59 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 68: ...31451 2 1013 Page 68 PARTS VIEW...