42603-4-0421
Page 12
Venting Graph (Dimensions in Feet)
1. Determine the height of the center of the termination. Using this
dimension on the Venting Graph, locate the point it intersects
with the slanted graph line, or the right edge of the graph.
2. From the point of this intersection, draw a vertical line to the
bottom of the graph.
3. Adjust the indicated maximum dimension for additional elbows
if necessary.
4. Position the unit so that maximum horizontal run is not exceeded.
Venting Requirements:
•
Minimum vertical rise from appliance outlet before any elbows =
12 inches (305mm) for DVP20MS(LP,NAT) and DVP30MSNAT
and 24 inches (610 mm) for DVP30MSLP.
•
Maximum vertical rise from appliance outlet = 40 feet (12.19 m).
•
Maximum vertical rise and horizontal run is a combined total
of 25 feet (7.62 m).
•
Maximum elbows = two 90°, for the second elbow subtract 5
feet from a horizontal run.
VENTING STOVE (
CONT'D
)
A
"A" Dimension
DVP20MS
24" (610mm)
DVP30MS
27" (686mm)
Figure 8 - Snorkel Installation
VENTING APPLICATIONS INFORMATION
Model
Venting Run
Description
DVP20
Propane
DVP20
Natural
DVP30
Propane
DVP30
Natural
DVKHP45
24" Vertical,
then 90
degree
elbow to
Horizontal
Termination
Yes
Yes
Yes
Yes
DVK45LP
Straight out
back with
Horizontal
venting and
termination.
May require
additional
venting
with 18"
maximum
Horizontal
run allowed.
Yes
No
No
No
DVK45NAT
Straight out
back with
Horizontal
venting and
termination.
May require
additional
venting
with 18"
maximum
Horizontal
run allowed.
No
Yes
No
No
DVKVP45
12" Vertical,
then 90
degree
elbow to
Horizontal
Termination.
Includes
a 11"- 17"
slip vent
section.
Yes
Yes
No
Yes
DVKVP45
Kit used
with a 14"
Snorkel on
outside of
building.
Yes
Yes
No
Yes
DVKVP45
Kit used
with a 36"
Snorkel on
outside of
building.
Yes
Yes
Yes
Yes
DVKVP
96" Vertical
Termination
Yes
Yes
Yes
Yes
Содержание DVP20MS
Страница 27: ...42603 4 0421 Page 27 DVP20MS LOG PLACEMENT 5 Assembly is completed TOP VIEW FRONT VIEW...
Страница 33: ...42603 4 0421 Page 33 DVP30MS LOG PLACEMENT 5 Assembly is completed TOP VIEW FRONT VIEW...
Страница 47: ...42603 4 0421 Page 47 Figure 35 Figure 36 MAINTENANCE CONT D...
Страница 64: ...42603 4 0421 Page 64 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 65: ...42603 4 0421 Page 65 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 66: ...42603 4 0421 Page 66 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...