42603-4-0421
Page 11
VENTING STOVE
Special Venting Notes:
•
DVP20CCNAT
- can be terminated horizontally with kit DVK45NAT
maximum 18".
•
DVP20CCLP
- can be terminated horizontally with kit DVK45LP
maximum 18".
• DVP20CC(LP,NAT)
- can use a 14" short snorkel or 36" tall snorkel.
• DVP30CC (NATURAL)
- Can be vented horizontally straight
out the back of stove if a minimum 14” snorkel is used. Or,
if venting horizontally, a 12” vertical vent is required off the
back of the stove before turning with an elbow horizontally
out the wall. See page 12.
• DVP30CC (PROPANE)
- Can be vented horizontally straight
out the back of the stove if a 36” snorkel is used. Or, if
venting horizontally, a 24” vertical vent is required off the
back of the stove before turning with an elbow horizontally
out the wall. See page 12.
CAUTION
Total vertical run MUST BE completed before starting horizontal
run. Horizontal chimney run must slope upward (away from
stove) 1/4" per foot and vent termination must be level.
Sidewall Venting
The maximum vertical and horizontal distances are 25 feet and 12
feet, respectively. Vertical dimensions are based on top of stove to
centerline of pipe. Horizontal dimensions are based on centerline
of pipe to termination.
Under no circumstances should combustible materials (including
siding) be closer than 3" from the top of the 6 5/8" pipe or closer
than 1" on the sides and bottom.
Cutting the Hole
After the appliance has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This
hole needs to be 10" high x 9" wide for 4 x 6 pipe and 12-1/2 high
x 10-1/2 wide for 5 x 8 pipe with its center line determined by the
amount of vertical arise and horizontal run of the termination. When
locating the hole it must be noted that the bottom of the cap must
be 12" above the ground level, and top of the cap must be no less
than 18" below a combustible projection, and no closer than 9" to
any wall running parallel to vent termination.
CHAPEAU D’ÉVACUATION
CHAPEAU D’ÉVACUATION
229 mm (9 po) VERS MUR LATÉRAL
229 mm (9 po) VERS MUR LATÉRAL
Figure 6
Co-Linear to Co-Axial Connection
A Co-Axial to Co-Linear appliance connector is approved for
installation in vertical venting applications. One can be purchased
through Empire Comfort Systems or Simpson Dealer (part number
46DVA-GCL).
(DVKI)
CHAPEAU D'ÉVACUATION
RACCORD ROND
COLINÉAIRE-COAXIAL
PRÊT-À-MONTER
DE TERMINAISON
DE CONDUIT
DE CHEMINÉE
TUYAU FLEXIBLE
PRISE D'AIR
ÉVACUATION
COAXIAL DROIT
RACCORD
COAXIAL-COLINÉAIRE
(SD46DVA-GCL)
COUDE DE 45°
(SD46DVA-E45B)
Figure 7
VENT CAP
9' (222MM TO SIDE WALL
VENT CAP
ROUND CO-LINEAR TO
CO-AXIAL CONNECTOR
CHIMNEY LINER
TERMINATION KIT
FLEX PIPE
CO-AXIAL TO
CO-LINEAR
CONNECTOR
(SD46DVA-GCL)
45° ELBOW
(SD46DVA-E45B)
STRAIGHT
CO-AXIAL
(DETERMINE
LENGTH NEEDED
& PURCHASE
SEPARATELY)
EXHAUST
INTAKE
VERTICAL
VENT KIT
(DVKI)
Содержание DVP20MS
Страница 27: ...42603 4 0421 Page 27 DVP20MS LOG PLACEMENT 5 Assembly is completed TOP VIEW FRONT VIEW...
Страница 33: ...42603 4 0421 Page 33 DVP30MS LOG PLACEMENT 5 Assembly is completed TOP VIEW FRONT VIEW...
Страница 47: ...42603 4 0421 Page 47 Figure 35 Figure 36 MAINTENANCE CONT D...
Страница 64: ...42603 4 0421 Page 64 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 65: ...42603 4 0421 Page 65 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 66: ...42603 4 0421 Page 66 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...