GAS INPUT FOR APPLIANCE CONVERTED TO PROPANE GAS:

DVP20CC70-1

19,500 Btu per hour

DVP30CC70-1

26,500 Btu per hour

The converted appliance when converted to Propane Gas will have 

a manifold pressure approximately 10.0"w.c. (2.49kPa) for maximum 

input or 5.9"w.c. (1.469kPa) for minimum input at the valve outlet 

with the inlet pressure to the valve from a minimum of 11.0"w.c. 

(2.739kPa) for the purpose of input adjustment to a maximum of 

13.0"w.c. (3.237kPa).

INSTRUCTIONS FOR CONVERSION

1.  If  appliance  is  installed,  turn  off  gas  and  electric  supply  to 

appliance before making gas conversion.

2.  Remove casting top from outer casting.

3.  Remove casting front from outer casting.

4.  Release two door latches at bottom of firebox. 

5.  lift off glass frame from the bottom channel.

6.  Carefully remove logs and set aside.

7.  Remove the log shelf by removing the two screws securing the 

log shelf to the rear wall. 

8.  Remove  four  10  x  1/2”  screws  from  burner  base  and  one 

 

8 x 1/4” screw from air shutter. Grasp burner assembly, lift and 

pull forward to remove burner assembly.

9.  Remove air shutter from orifice fitting.

10.  Remove Natural Gas main burner orifice from orifice fitting.

11.  Install Propane Gas main burner orifice into orifice fitting: 

 

for DVP20CC ORIFICE 

MARKED 55

 

for DVP30CC ORIFICE 

MARKED 1.55mm

12.  Thread air shutter onto orifice fitting.

13.  Remove the screws holding the pilot in place; carefully flex 

the pilot backwards to clear the bracket.

14.  Remove  the  burners  by  sliding  both  burners  to  the  right  to 

disengage the orifice holders.

15.  Replace the pilot orifice with the one included in the kit. DO 

NOT overtighten.

16.  Replace the screws that secure the pilot to the burner bracket.

17.  Convert  gas  valve  as  instructed  in  the  S.I.T.  Gas  Valve 

Conversion kit.

18.  Align  burner  assembly  with  air  shutter  as  you  place  burner 

assembly into original position in firebox.

19.  Adjust air shutter setting to 

Full Open.

20.  Attach air shutter to burner assembly with one 8 x 1/4” screw 

from Step 8.

21.  Attach burner assembly to firebox bottom with four 10 x 1/2” 

screws from Step 8.

22.  Remove flue vent baffle (17-5/16” wide). Install new flue vent 

baffle (6-5/8” wide, DVP30CC only). 

See Figure 1.

23.  Replace the log shelf and secure to the rear wall by replacing 

the two screws removed in step 7.

24.  Replace logs per instruction in Owner's Manual.

25.  Place glass frame onto firebox and attach two door latches to 

bottom of firebox.

26.  The converted appliance must be connected to a supply of the 

conversion gas and checked for leaks at all connections.

27.  The appliance must be checked to ensure it is operating at the 

correct pressure of 10.0" w.c.

28.  Conversion is completed. 

PARTS LIST - CONVERSION KIT 31054

Part 

Description

Part 

Number

Quantity 

Supplied

Pilot Orifice

R10426

1

Regulator Kit, SIT 886 (Propane Gas)

R11169

1

Main Burner Orifice - DVP20CC

P182 (#55)

1

Gas Conversion Label

R1321

1

Conversion Label

R1322

1

PARTS LIST - CONVERSION KIT 31060

Part 

Description

Part 

Number

Quantity 

Supplied

Pilot Orifice

R10426

1

Regulator Kit, SIT 886 (Propane Gas)

R11169

1

Main Burner Orifice - DVP30CC

P258 (#1.55)

1

Vent Flue Baffle - DVP30CC

30879

1

Gas Conversion Label

R1321

1

Conversion Label

R1322

1

Figure 1