31064-2-0919

Page 1

Empire Comfort Systems Inc. • Belleville, IL

GAS CONVERSION INSTRUCTIONS

DIRECT VENT STOVES

FOR USE ON DIRECT VENT STOVE MODELS: 

DVP20CC70-1,   DVP30CC70-1

CONVERSION KITS

MODEL

PART NUMbER

DVP20CC70-1

31054

DVP30CC70-1

31060

 FOR CONVERSION TO 

PROPANE GAS

WARNING

This conversion kit is to be installed by an Empire Comfort Systems, Inc.  distribu tor (or other 

qualified agency

1

)* in accordance with the manufac turer’s instruc tions and all codes and re-

quirements of the authority having jurisdiction.  Failure to follow instructions could result in 

serious injury or property damage.  The qualified agency performing this work assumes re-

sponsibility for this conversion.

1

 National Fuel Gas Code Z223.1 (Latest Edition), Natural Gas and Propane Installation Code, 

CSA b149.1

*The term “qualified agency” means any individual, firm, corporation or company which either 

in person or through a representative is engaged in and is responsi ble  for (a) the installation 

of gas piping or (b) the connection, installation repair, or servicing of equipment, who is ex-

perienced in such work, familiar with all precau tions required, and has complied with all the 

requirements of the authority having jurisdic tion.

CHECK SAFETY SHUTDOWN PERFORMANCE

 

WARNING

Perform the safety shutdown test anytime work is done on a gas system to avoid the possibility 

of fire or explosion with property damage, personal injury or loss of life.

SAFETY SHUTDOWN SYSTEM

Continuous Ignition Systems (Standing Pilot)

1.  Place gas control knob in PIlOT position.  Main burner should go off and pilot should remain lit.

2.  Extinguish pilot flame. Pilot gas flow should stop within 30 seconds. Safety shutoff of pilot gas proves complete shutdown 

since safety shutoff valve blocks flow of gas to main burner and pilot.

3.  Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.