34829-1-0115
Page 13
INSTALLATION (continued)
VERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
►
▼
◄
►
◄
▲
▲
►
◄
A
A
B
C
6 INCH
11-3/4" TO 12-3/4"
(298mm TO 323mm)
4-3/4" TO 6-1/4"
(121mm TO 159mm)
9 INCH
14-1/4" TO 15-3/4"
(362mm TO 400mm)
7-3/4" TO 9-1/4"
(197mm TO 235mm)
12 INCH
17-1/4" TO 18-3/4"
(438mm TO 476mm)
10-3/4" TO 12-1/4"
(273mm TO 311mm)
Figure 19
CORNER INSTALLATION VERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
▲
▼
◄
▼
▼
◄
◄
▼
▲
B
A
D
C
►
►
E
VENT CAP/
THIMBLE
WALL
FIRESTOP
DVLT/DVTT36
DVLT/DVTT42
A
72-11/16"
(1853 mm)
77-1/4"
(1962 mm)
B
51-9/16"
(1310 mm)
54-5/8"
(1387 mm)
C
25-11/16"
(652 mm)
27-7/8"
(708 mm)
D
103-1/8"
(2620 mm)
109-1/4"
(2775 mm)
E
19-11/16"
(500 mm)
21-7/8"
(555 mm)
Figure 20
Corner installation may require more vertical than just the
minimum required depending on wall thickness and horizontal
dimension.
IMPORTANT:
MINIMUM HEIGHT OFF THE TOP REQUIREMENTS
DVLT36FP & DVTT36FP - MUST USE a 1 FT (305 mm) vent
pipe as the first section BEFORE installing the elbow.
DVLT42FP & DVTT42FP - MUST USE a 2 FT (610 mm) vent
pipe as the first section BEFORE installing the elbow.
Содержание DVLT36FP92N-2
Страница 30: ...34829 1 0115 Page 30 Figure 47 36 BOTTOM LOG PLACEMENT B I H A C J M K L E DVTT36 LOG PLACEMENT...
Страница 34: ...34829 1 0115 Page 34 DVTT42 LOG PLACEMENT Figure 49 42 BOTTOM LOG PLACEMENT B I H G A D C J M K L E F N...
Страница 59: ...34829 1 0115 Page 59 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...