
34829-1-0115
Page 11
INSTALLATION (continued)
Flush Mount Installation
The fireplace must extend 3/4” (19mm) beyond finished wall surface
when using a flush mount. Refer to Figure 12 to locate nailing flanges
on fireplace sides. Mark and drill two 1/8” holes into fireplace side to
mount each nailing flange. Use eight 1/2” hex-head screws supplied
in hardware package to attach nailing flanges to fireplace sides.
▲
Figure 12
Flush Wall Installation
1/2” (12 mm) NON- COMBUSTIBLE
NON- COMBUSTIBLE FINISHED WALL
ALL FIREPLACE METAL MUST BE
COVERED WITH NON-COMBUSTIBLE
MATERIAL ONLY
TOP OF FIREPLACE OPENING
IMPORTANT: NO FINISHING
MATERIAL OF ANY TYPE MAY
EVER OVERLAP THE OPENING
OF THE SIDES OR TOP.
GLASS WILL NOT FIT
IF IT DOES.
STANDOFF
2 X 4 OR 2 X 6
SHOWN VERTICAL
MAY BE HORIZONTAL
AND/OR DOUBLED UP
◄
▼
◄
◄
▼
▼
Figure 13
Framing and Finishing
1. Choose unit location.
2. Frame in fireplace with a header across the top. It is important
to allow for finished face when setting the depth of the frame.
3. Attach fireplace to frame.
See Figure 14.
Figure 14
Содержание DVLT36FP92N-2
Страница 30: ...34829 1 0115 Page 30 Figure 47 36 BOTTOM LOG PLACEMENT B I H A C J M K L E DVTT36 LOG PLACEMENT...
Страница 34: ...34829 1 0115 Page 34 DVTT42 LOG PLACEMENT Figure 49 42 BOTTOM LOG PLACEMENT B I H G A D C J M K L E F N...
Страница 59: ...34829 1 0115 Page 59 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...