background image

38267-1-0319

Page 7

INTRODUCTION

The information in this manual pertains to all models and gas 

control systems unless otherwise noted.

Instructions to Installer

1.  Leave this manual with Homeowner.

2.  Have the homeowner complete the Product Registration 

Card or register online at www.empirecomfort.com

3.  Show the homeowner how to start and operate the fireplace.

Notes to Installer

 

This fireplace is designed to:

Operate with combustion air siphoned from outside of 

the building. 

Expel all exhaust gases to the outside of the building.

 

The installation must conform with local codes or, in the 

absence of local codes, with the National Fuel Gas Code 

ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation 

Code, or CSA B149.1 in Canada. * Available from the 

American National Standards Institute, Inc. 11 West 42nd 

St., New York, N.Y. 10036

 

Any alteration of the original design, installation other than 

as shown in these instructions, or use with a type of gas not 

shown on the rating plate is the responsibility of the person 

and company making the change.

 

This fireplace is not for use with solid fuels.

 

These fireplace models may be installed in a bedroom or 

bed-sitting room in the U.S.A. and Canada.

WARNING

Any  change  to  this  fireplace  can  be  dangerous.  Improper 

installation or use can cause serious injury or death from fire, 

burns, explosion or carbon monoxide poisoning.

Fireplace Certification

This fireplace is design certified in accordance with American 

National Standard/CSA Standard ANSI Z21.88/CSA 2.33 and by 

Underwriters Laboratories as a Direct Vent Gas Fireplace Heater 

and shall be installed according to these instructions.

Consult your local building code agency, prior to installation, 

to ensure compliance with local codes-including permits and 

inspections.

The fireplace, when installed, must be electrically grounded in 

accordance with local codes or, in absence of local codes, with 

the National Electric Code ANSI/NFPA 70 or Canadian Electric 

code, CSA C22.1, if an external electrical source is utilized.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization 

equipment or accessories and repair and servicing of equipment 

shall be performed only by a qualified agency. The term 

qualified 

agency

 means any individual, firm, corporation or company 

which either in person or through a representative is engaged 

in and is responsible for (a) the installation or replacement of 

gas piping or (b) the connection, installation, repair or servicing 

of equipment, who is experienced in such work, familiar with all 

precautions required and has complied with all the requirements 

of the authority having jurisdiction.

Commonwealth of Massachusetts: The installation must be 

made by a licensed plumber or gas fitter in the Commonwealth 

of Massachusetts.

High Altitude (USA) 

When installing this fireplace at an elevation above 2000 feet 

(in the United States) it may be necessary to decrease the input 

rating by changing the existing burner orifice to a smaller size. 

Generally, input should be reduced 4 percent for each 1000 

feet above sea level. However, if the heating value of the gas 

has been reduced, this general rule may not apply. Check with 

Empire Comfort System’s local gas utility for proper orifice size 

identification.

High Altitude (CANADA) 

Altitude: 0-4500 feet (0-1370 m)

When installing this fireplace at an elevation above 4500 feet 

(in Canada), check with local authorities.

Consult your local gas utility for assistance in determining the 

proper orifice for your location.

HOMEOWNER REFERENCE INFORMATION

We recommend that you record the following information about your fireplace.

Model Number: 

 _____________________________

 

Date purchased:

 ________________________

Serial Number: 

 _____________________________

 

Location of fireplace:

 _____________________

Dealer Name: 

 ______________________________

 

Dealer Phone: 

 _________________________

Notes:

 ______________________________________________________________________________

Содержание DVCT50CBP95-1

Страница 1: ...ed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate...

Страница 2: ...raming 22 23 Vent System Identification 24 Special Vent Systems 24 Venting Fireplace 26 27 Horizontal Termination 28 Vertical Termination 29 31 Air Shutter Adjustment 32 Control System Troubleshooting...

Страница 3: ...____________________ Venting installed locked secured in place with correct clearance o _____________________ Firestops installed o _____________________ Exterior wall roof flashing installed and seal...

Страница 4: ...ng installation and follow them carefully to ensure safety Failure to follow the instructions will void the warranty and may cause a fire hazard The warranty will be voided by and the warranter discla...

Страница 5: ...our perimeter edges on the bottom of the fireplace such as on cinder blocks where allowed by local codes If the fireplace is installed directly on carpeting tile or other combustible material other th...

Страница 6: ...llet 1 7 Remote 1 8 Battery Holder Switch 1 See Parts Lists on page 61 for ordering replacement parts Do not order batteries bolts screws washers or nuts They are standard hardware items and can be pu...

Страница 7: ...l codes with the National Electric Code ANSI NFPA 70 or Canadian Electric code CSA C22 1 if an external electrical source is utilized Qualified Installing Agency Installation and replacement of gas pi...

Страница 8: ...ENT 5 x 8 Direct Vent System 35w Clear Halogen Bi Pin 6 35mm base 120vac UL ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer For additional information...

Страница 9: ...ce 19 1 4 G The rear exterior width of the fireplace 36 3 16 H The height to the fireplace standoffs N A I Width from the left side to the centerline of vent 21 J Depth from back to centerline of top...

Страница 10: ...ers and the other end to the Wire Assembly supplied with the fireplace See Figure 5 TO WIRE ASSEMBLY MODULE TO WIRE ASSEMBLY MODULE Figure 5 5 Replace Blower Access Panels removed in step 1 See Figure...

Страница 11: ...ith 2 screws HAND BEND TAB INWARD HAND BEND TAB INWARD Figure 11 7 Remove protective connectors on Wire Assembly from fireplaceanddiscard ConnectWireHarnesstobothblowers and the other end to the Wire...

Страница 12: ...6 152 mm TO FIREPLACE OPENING 35 889mm TO FIREPLACE OPENING Figure 17 CLEARANCES Clearance to Combustibles Dimension in inches Back 0 Side 2 Floor 0 Top of Unit 36 Top Framing Edge 0 FINISHED WALL COM...

Страница 13: ...tthattheventingsystemmaintainitsbalance between the combustion air intake and the flue gas exhaust certain limitations as to vent configurations apply and must be strictly adhered to Figure 18 The gra...

Страница 14: ...E Clearance to unventilat ed soffit 18 in 18 in M Clearance under veranda porch deck or balcony 12 in 30cm 12 in 30cm F Clearance to outside corner See previous page 1 In accordance with the current...

Страница 15: ...r a soap solution After testing is complete all solution should be cleaned off On unexposed connections a pressure test should be made WARNING Never use an exposed flame to check for leaks Fireplace m...

Страница 16: ...iary device amperage limit is 5 amps NOTICE A one inch diameter hole should be use to pass wiring through studs BLACK HOT JUNCTION BOX WHITE NEUTRAL GROUND TO JUNCTION BOX 120 VOLT POWER SUPPLY JUNCTI...

Страница 17: ...VALU PAR TEMP RATURE ORANGE PILOT GAS CONTROL VALVE ORANGE GREEN YELLOW WHITE BLACK WHITE BLOWER FUSE BLACK WHITE GREEN TO JUNCTION BOX LOOP TO LIGHTS SPLIT FLOW SOLENOID SLEEVE USER INTERFACE BATTER...

Страница 18: ...ry blocks These supports must be positioned so they contact all four perimeter edges on the bottom of the fireplace if allowed by local codes NOTICE Verify the gas supply and electrical considerations...

Страница 19: ...Figure 32 Figure 33 WARNING When finishing the fireplace never obstruct or modify the gap around the glass frame in any manner Provide adequate clearances around air openings into the combustion chamb...

Страница 20: ...T 1 25 mm 5 DIAMETER FLUE 1 25 mm Horizontal Vent Clearances Figure 35 ATTENTION Cold climate installation recommendation When installing this unit against an exterior wall the exterior wall must be i...

Страница 21: ...HORIZONTAL OUT THE WALL 12 inch minimum rise before elbow WALL FIRESTOP THIMBLE SPACER VENT CAP 6 MINIMUM 9 MINIMUM D B A C DIMENSION DVCT50 A 60 3 16 B 42 9 16 C 20 9 16 D 85 1 8 Figure 37 VERTICAL...

Страница 22: ...k heat shield and as a means to insure that minimum clearances are maintained to the vent system Horizontal Firestops Horizontal runs in the vent system which pass through either interior or exterior...

Страница 23: ...iously marked Frame the hole with framing lumber the same size as the ceiling joists See Figure 42 If the area above the ceiling is NOT an attic position and secure the ceiling firestop on the ceiling...

Страница 24: ...ting to be installed and the path that it will take Verify that clearances are met throughout the path of the venting system NOTICE These fireplaces cannot be vented out the rear Determine how the ven...

Страница 25: ...cation dimensions for through the wall horizontal installations with 90 degree elbow and 12 inch rise off top of fireplace See Figure 53 on page 27 for permissible H and V dimensions Figure 47 GENERIC...

Страница 26: ...he building 14 inch and 36 inch tall Snorkel Terminations are available Follow the same installation procedures as used for standard Horizontal Terminations If the Snorkel Termination must be installe...

Страница 27: ...et so the horizontal run to the outer wall flange must not exceed 5 feet EXAMPLE B Medium Vertical Theverticaldimensionfromthefloortothecenterlineofthehorizontal venting is 24 1 2 feet so the horizont...

Страница 28: ...24 7 9 36 8 12 48 9 15 Figure 55 GENERIC MODEL SHOWN Two 90 Elbows NOTE Subtract 3 feet from the total horizontal measurement for each 90 elbow installed horizontally Subtract 1 1 2 feet from the tot...

Страница 29: ...rtical but cannot exceed 18 ft Figure 59 GENERIC MODEL SHOWN Three 90 Elbows NOTE Subtract 3 feet from the total horizontal measurement for each 90 elbow installed horizontally Subtract 1 1 2 feet fro...

Страница 30: ...omponents should immediately 2 Remove the cap and shine a flashlight down the vent Remove any bird nests or other foreign material 3 Check for evidence of excessive condensate such as water droplets f...

Страница 31: ...up to 40 feet in height b Two sets of 45 degree elbow offsets within these vertical installations From 0 to a maximum of 8 ft a vent pipe can be used between elbows c Wall straps must be used to suppo...

Страница 32: ...ndles See Figure 67 Loosen 2 air shutter handle screws Figure 67 3 Replace glass door See maintenance and service section of this manual 4 Turn unit on see operating instructions in home owner s instr...

Страница 33: ...38267 1 0319 Page 33 This page is intentionally left blank...

Страница 34: ...Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 If pilot flow adjuster screw is not sea...

Страница 35: ...ions 5 Remove the provided wiring harnesses from EV2 of gas valve red base and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is gre...

Страница 36: ...nance and Service section for Instructions Glass Frame Assembly See Maintenance and Service section for Instructions Figure 69 2 Remove the log set and set aside 3 Remove the top liner bracket and top...

Страница 37: ...w c Propane Gas will have a manifold pressure approximately 10 0 inches w c at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11 0 inches w c for the...

Страница 38: ...R12591 BURNER TUBE REAR 28 R12283 PILOT ASSEMBLY CONVERTIBLE 29 38615 PILOT BRACKET 30 R12590 BURNER TUBE FRONT 31 39917 BURNER BASE ASSEMBLY 32 39914 AIR BOX ORIFICE ASSEMBLY 33 R12171 CABLE STOP 34...

Страница 39: ...38267 1 0319 Page 39 EXPLODED VIEW 1 2 26 25 4 14 3 5 28 29 6 13 15 17 18 19 22 10 9 21 8 11 12 7 44 45 20 16 42 41 30 27 31 24 23 32 34 37 43 36 33 35 38 39 40...

Страница 40: ...f of the fireplace To access the light bulb you will remove the following items by removing four screws per light See Figure 76 metal bezel glass gasket NOTE Use gloves when handling light bulb oils o...

Страница 41: ...for the protection of children and other at risk individuals Barrier required but may be sold separately If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier fo...

Страница 42: ...al integrity See Figure 81 Inspect the log set if applicable and decorative media if applicable for debris or damage Freshen up the glowing embers if applicable Replace batteries in the remote transmi...

Страница 43: ...ons shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum...

Страница 44: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 45: ...38267 1 0319 Page 45 Date Dealer Name Service Technician Name Service Performed Notes APPLIANCE SERVICE HISTORY...

Страница 46: ...38267 1 0319 Page 46 Date Dealer Name Service Technician Name Service Performed Notes APPLIANCE SERVICE HISTORY...

Страница 47: ...n Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale canceled check or payment re...

Страница 48: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Отзывы: