Lockout State Definition

A lockout state is reached when an ignition error occurs. The 

lockout state will remain set in memory as long as the power 

supplies are applied.

This could mean both an irregular flame detection and/or too 

many unsuccessful ignition attempts. 

This state is a safe condition for the appliance and is entered 

automatically by the IFC board. 

When the IFC board gets into lockout state:

1.  both the Pilot and the main Burner solenoids in the gas valve 

are de-energized;

2.  a diagnostic code is sent through the diagnostic red LeD.

3.  the IFC board will ignore any burner ignition command and 

remain in the oFF state unless the unlock command se-

quence is met.

The causes of lockout must be investigated under safe conditions 

by the user and/or the service personnel.

To reset the IFC from a lockout state, perform the following pro-

cedure:

 

Turning the system power supplies (to the wall control or 

remote control) oFF for two or three seconds and then 

restoring a power supply back on.

The return of the system to normal operation must be checked 

under safe conditions by the user and/or service personnel.

Using the Fireplace without a Remote Control

The fireplace can be turned oN (HI only) and oFF with the wall 

switch. The fireplace flame oN/oFF is the only function that will 

operate; no flame adjustment, light or blower will work when us-

ing the wall switch. The wall control switch should be turned oFF 

when the fireplace is not being used for extended periods of time.

Battery Backup Operation

Install batteries (See initialization sequence on page 44). In case 

of power loss, the fireplace will switch to battery mode automat-

ically. The fireplace will operate normally without the fan or light 

control when in battery mode.

Low Battery Detection

When the backup batteries are low, a double-beep will be emitted 

when the module receives an on/off command. No commands 

will be accepted until the batteries are replaced or the A/C power 

is restored.

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS

Содержание DVCT40CSP-OUT

Страница 1: ...nity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perf...

Страница 2: ... to the fireplace This is a heating appliance The flow of heat can ignite combustibles Figure 1 GENERIC MODEL SHOWN COMBUSTIBLE MATERIAL TABLE OF CONTENTS SECTION PAGE Multifunction Remote Operating Instructions 3 9 Lighting Instructions 10 Maintenance And Service 11 12 Important Safety Information 13 Safety Information For Users Of Propane Gas 14 Requirements For Massachusetts 15 Warranty 16 ...

Страница 3: ...rner when operating the remote system or activating manual bypass of the remote system CAUTION Property Damage Hazard Excessive heat can cause property damage The appliance can stay lit for many hours Turn off the appliance if it is not going to be attended for any length of time Always place the Transmitter where children can not reach it Figure 3 NOTE This control system includes a Battery Back ...

Страница 4: ...with a paper clip and the IFC module will beep three times to indicate the IFC module is ready to synchronize with the transmitter within ten seconds See Figure 5 Figure 4 SWI BUTTON Figure 5 5 With the batteries already installed in the Transmitter push the On button The Receiver will beep four times to indicate the Transmitter s command is accepted and sets to the par ticular code of that Transm...

Страница 5: ...m the Receiver confirms reception of the command Remote Control Display Figure 9 Remote Flame Control The Proflame has six flame levels With the system on and the flame level at the maximum in the appliance pressing the Down Arrow Button once will reduce the flame height by one step until the flame is turned off The Up Arrow Button will increase the flame height each time it is pressed If the Up A...

Страница 6: ... Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Button until the word SMART appears to the right of the temperature bulb gr...

Страница 7: ...plit Flow To activate this function use the Mode Button Figure 3 to index to the SPLIT FLOW mode icon See Figures 22 and 23 Pressing the Up Arrow Button will activate the secondary burner Pressing the Down Arrow Button will turn the secondary burner off A single beep will confirm the reception of the command OFF Figure 22 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS OFF Figure 23 Remote Auxiliary R...

Страница 8: ... to avoid unsupervised operation To activate this function press the MODE and UP Buttons at the same time See Figure 28 To deactivate this function press the MODE and UP Buttons at the same time OFF Figure 28 Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the num...

Страница 9: ... the wall control or remote control OFF for two or three seconds and then restoring a power supply back on The return of the system to normal operation must be checked under safe conditions by the user and or service personnel Using the Fireplace without a Remote Control The fireplace can be turned ON HI only and OFF with the wall switch The fireplace flame ON OFF is the only function that will op...

Страница 10: ...HTING INSTRUCTIONS 1 STOP Read the safety information above 2 Turn OFF electric power to the appliance 3 Turn gas shut off knob counterclockwise to ON position 4 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you do not smell gas go to the next step 5 Turn ON electric power to the app...

Страница 11: ...nd at least annually Inspect the external vent cap on a regular basis to make sure no debris is interferes with the air flow Cleaning the Glass Clean the glass periodically We recommend gas fireplace glass cleaner During start up condensation forms on the inside of the glass causing lint dust and other airborne particles to cling to the glass Also initial paint curing may deposit a film on the gla...

Страница 12: ...Places LAT CH Glass Latch Tool LAT CH L A T C H Figure 31 Light Bulb s Replacement 1 Remove the following items barrier screen glass frame assembly This unit comes standard with two lights that are attached to the roof of the fireplace To access the light bulb you will remove the following items by removing four screws per light See Figure 32 metal bezel glass gasket NOTE Use gloves when handling ...

Страница 13: ...objects on or around the fireplace that may restrict air flow Keep the area around the fireplace free of combustible materials including drapery upholstered furniture paper boxes and clothing Never hang stockings or cards above the fireplace Never operate the fireplace with the glass front removed or damaged Any part removed for cleaning or servicing must be replaced prior to operating the firepla...

Страница 14: ...ed gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air theremaybemoreodoratlowerlevels Alwaysbesensitive to the slightest gas odor If you detect any odor t...

Страница 15: ...20 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating fireplace or equipment The sign shall read in print size no less than 1 2 inch in size GAS VENT DIRE...

Страница 16: ...the instructions furnished with the appliance A bill of sale canceled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this appliance Travel diagnostic costs and freight charges on warranted parts to and from the factory...

Отзывы: