IMPORTANT SAFETY INFORMATION

Annual Inspection

 

Have the fireplace inspected annually before use. 

• 

more frequent inspection and cleaning may be required if the 

fireplace is installed in an area exposed to pet hair or dust, 

or to excessive lint from new carpeting or bedding materials.  

During The Annual Checkup, The Technician Will: 

• 

Inspect the pilot (flame safety system) and burner(s) for 

proper operation and replace any damaged parts. 

• 

Check the glass and gasket for proper seal. 

• 

Vacuum and clean any foreign debris in the firebox that is 

not supposed to be there.

• 

Clean Glass with a suitable fireplace glass cleaner. Abrasive 

cleaners must not be used. Be careful not to scratch the 

glass when cleaning.

• 

Check the barrier screen for fit and structural integrity. 

See 

Figure 30.

• 

Check all latches or other door retention components for 

proper operation, tension, and relief mechanisms are free 

from obstructions. 

See Figure 31.

• 

Inspect the log set (if applicable) and decorative media (if 

applicable) for debris or damage.

• 

Freshen up the glowing embers if applicable.

• 

Replace batteries in the remote transmitter and receiver if 

applicable.

• 

Inspect the venting and vent termination cap for damage, 

corrosion, sooting, or obstruction and correct if present.

• 

In addition, clean and inspect the fireplace following any 

remodeling work in your home.

FOR THE HOMEOWNER

 

This fireplace must be installed and serviced by your dealer 

or a qualified service technician. other than cleaning the 

glass and replacing the light bulbs, there are no user-

serviceable components.

 

Keep the area around the fireplace clean and free of debris.  

This fireplace requires an unimpeded flow of air to circulate 

warm air. Do not place objects on or around the fireplace that 

may restrict air flow.  

 

Keep the area around the fireplace free of combustible 

materials – including drapery, upholstered furniture, paper, 

boxes, and clothing.  Never hang stockings or cards above 

the fireplace.  

 

Never operate the fireplace with the glass front removed or 

damaged.  Any part removed for cleaning or servicing must 

be replaced prior to operating the fireplace. 

 

The fireplace gets hot during operation and may remain hot 

for an hour after use.  When operated by thermostat, the 

fireplace will turn on and off automatically.  

• 

This fireplace may become hot enough to burn skin and 

ignite clothing after prolonged contact. To prevent injury, alert 

people in your home – especially children – to the hazards of 

high surface temperatures and warn them to stay away from 

the fireplace. 

• 

Supervise children whenever the fireplace is hot. Young 

children and others may be susceptible to accidental contact 

burns. Have your dealer install a physical barrier if there 

are at-risk individuals in your home. To restrict access to a 

fireplace or stove, install an adjustable safety gate to keep 

toddlers, young children, and other at-risk individuals out of 

the room and away from hot surfaces. 

• 

The vent cap, located on the outside of your home, will also 

become very hot. Alert everyone, adults and children, to stay 

clear and avoid touching the vent cap. Keep the area around 

the vent cap clear of combustibles, including shrubs and trees.  

 

Do not use this fireplace if any part has been underwater. 

Have a qualified technician inspect the fireplace and replace 

any part that has been underwater. In the event of a natural 

disaster (tornado, earthquake, fire, etc.) have a qualified 

technician inspect the fireplace for damage or potential gas 

leaks. Repair or replace any damaged components before 

operating this fireplace.

 

Never burn solid fuels such as wood, coal, paper or 

cardboard in this fireplace.

Содержание DVCT40CSP-OUT

Страница 1: ...nity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perf...

Страница 2: ... to the fireplace This is a heating appliance The flow of heat can ignite combustibles Figure 1 GENERIC MODEL SHOWN COMBUSTIBLE MATERIAL TABLE OF CONTENTS SECTION PAGE Multifunction Remote Operating Instructions 3 9 Lighting Instructions 10 Maintenance And Service 11 12 Important Safety Information 13 Safety Information For Users Of Propane Gas 14 Requirements For Massachusetts 15 Warranty 16 ...

Страница 3: ...rner when operating the remote system or activating manual bypass of the remote system CAUTION Property Damage Hazard Excessive heat can cause property damage The appliance can stay lit for many hours Turn off the appliance if it is not going to be attended for any length of time Always place the Transmitter where children can not reach it Figure 3 NOTE This control system includes a Battery Back ...

Страница 4: ...with a paper clip and the IFC module will beep three times to indicate the IFC module is ready to synchronize with the transmitter within ten seconds See Figure 5 Figure 4 SWI BUTTON Figure 5 5 With the batteries already installed in the Transmitter push the On button The Receiver will beep four times to indicate the Transmitter s command is accepted and sets to the par ticular code of that Transm...

Страница 5: ...m the Receiver confirms reception of the command Remote Control Display Figure 9 Remote Flame Control The Proflame has six flame levels With the system on and the flame level at the maximum in the appliance pressing the Down Arrow Button once will reduce the flame height by one step until the flame is turned off The Up Arrow Button will increase the flame height each time it is pressed If the Up A...

Страница 6: ... Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Button until the word SMART appears to the right of the temperature bulb gr...

Страница 7: ...plit Flow To activate this function use the Mode Button Figure 3 to index to the SPLIT FLOW mode icon See Figures 22 and 23 Pressing the Up Arrow Button will activate the secondary burner Pressing the Down Arrow Button will turn the secondary burner off A single beep will confirm the reception of the command OFF Figure 22 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS OFF Figure 23 Remote Auxiliary R...

Страница 8: ... to avoid unsupervised operation To activate this function press the MODE and UP Buttons at the same time See Figure 28 To deactivate this function press the MODE and UP Buttons at the same time OFF Figure 28 Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the num...

Страница 9: ... the wall control or remote control OFF for two or three seconds and then restoring a power supply back on The return of the system to normal operation must be checked under safe conditions by the user and or service personnel Using the Fireplace without a Remote Control The fireplace can be turned ON HI only and OFF with the wall switch The fireplace flame ON OFF is the only function that will op...

Страница 10: ...HTING INSTRUCTIONS 1 STOP Read the safety information above 2 Turn OFF electric power to the appliance 3 Turn gas shut off knob counterclockwise to ON position 4 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you do not smell gas go to the next step 5 Turn ON electric power to the app...

Страница 11: ...nd at least annually Inspect the external vent cap on a regular basis to make sure no debris is interferes with the air flow Cleaning the Glass Clean the glass periodically We recommend gas fireplace glass cleaner During start up condensation forms on the inside of the glass causing lint dust and other airborne particles to cling to the glass Also initial paint curing may deposit a film on the gla...

Страница 12: ...Places LAT CH Glass Latch Tool LAT CH L A T C H Figure 31 Light Bulb s Replacement 1 Remove the following items barrier screen glass frame assembly This unit comes standard with two lights that are attached to the roof of the fireplace To access the light bulb you will remove the following items by removing four screws per light See Figure 32 metal bezel glass gasket NOTE Use gloves when handling ...

Страница 13: ...objects on or around the fireplace that may restrict air flow Keep the area around the fireplace free of combustible materials including drapery upholstered furniture paper boxes and clothing Never hang stockings or cards above the fireplace Never operate the fireplace with the glass front removed or damaged Any part removed for cleaning or servicing must be replaced prior to operating the firepla...

Страница 14: ...ed gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air theremaybemoreodoratlowerlevels Alwaysbesensitive to the slightest gas odor If you detect any odor t...

Страница 15: ...20 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating fireplace or equipment The sign shall read in print size no less than 1 2 inch in size GAS VENT DIRE...

Страница 16: ...the instructions furnished with the appliance A bill of sale canceled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this appliance Travel diagnostic costs and freight charges on warranted parts to and from the factory...

Отзывы: