BLOWER INSTALLATION
6
2
3
4
1
5
7
BLOWER ASSEMBLY PARTS LIST
INDEX
NO.
PART
NO
DESCRIPTION
QTY
1
36118
BLOWER ASSEMBLY
1
2
R7649
FAN, CONTROL L120-20
1
3
R3529
CORD SET, 30 INCHES
1
4
R4192
RHEOSTAT, KNOB
1
5
R4186
RHEOSTAT, 3.0 AMP 115 VAC
1
6
10088
RHEOSTAT BOX BRACKET
1
7
R11768
WIRE HARNESS, FAN CONTROL
1
BLOWER INSTALLATION
1. Remove the glass and screen frames, and the bottom
access panel from the side which is opposite the valve.
The glass and screen frame may be removed as a unit. It is
not necessary to separate the screen frame from the glass
frame.
2. Hold the blower assembly so that the magnets are on your
right side, and insert it into the fireplace through the opening
to the right of the junction box.
See Figure 1.
Figure 1
3. Attach the magnet-side of the blower assembly to the outer
wall of the fireplace, and center it inside the fireplace using
the two holes in the floor as a visual guide.
See Figure 1.
4. Set the rheostat control on the fireplace floor, with the
rheostat bracket situated as far to the right as possible.
See
Figure 2.
Figure 2
5. Snap the fan control disc into the forked prongs on the valve
bracket.
See Figure 3.
Figure 3
6. If more than one receptical is necessary in order to complete
the installation, unscrew the junction box from the locating
tabs so that it can be moved rearwards and plug the blower
cord into one of the two bottom recepticals.
See Figures 4
and 5.
Figure 4
Figure 5
7. Re-attach the junction box to the locating tabs.
8. Re-install the glass and screen frames, and the access
panel.